This paper presents the results of seven experimental tests in reinforced concrete wide beams, aiming to investigate their performance when subjected to shear, using prefabricated truss stirrups as shear reinforcement, as well as a supplementary reinforcement to control cracks by delamination. The main analysed variables were: position of the supplementary reinforcement, inclination of the shear reinforcement, and spacing between stirrups. Results showed that strength increments of up to 142% were obtained using the prefabricated truss stirrups. Furthermore, the experimental results were compared with the theoretical shear strength estimates of the tested beams, following the recommendations of NBR 6118 (2014), Eurocode 2 (2004), and ACI 318 (2014), in order to evaluate the safety level of these codes when designing concrete elements subjected to shear with the reinforcement used in this paper.
1 January 2023 in Revista IBRACON de Estruturas e Materiais
Reinforced concrete elements with a high longitudinal and transverse reinforcement ratio may present conflicts on both of them, resulting in reduced labor productivity and a poor job when assembling the transversal reinforcement, reducing its effectiveness. Thus, this research presents a type of internal transverse reinforcement as an alternative to mitigate this conflict between the transverse and longitudinal bars. A total of 5 reinforced concrete wide beams were made, one of them as a reference with closed stirrups, and the other ones with internal stirrups, varying the inclination of the internal transverse reinforcement in 60° and 90°, and the number of vertical legs of the internal transverse reinforcement used. Comparing the results of the beams with internal stirrups with the reference beam, it was observed that the internal stirrups provided increases of up to 14% in shear strength when compared with the closed stirrup.
This paper examines the impacts of the total replacement of Natural Coarse Aggregates (NCA) by Recycled Concrete Coarse Aggregates (RCA) on the mechanical properties in concrete's fresh and hardened state. It also investigates the impact of RCA on the response and resistance of slab-column connections with and without shear reinforcement. The total replacement of NCA by RCA reduced by 21.8% and 37.1% the compressive and tensile strength of concrete for the concrete mix investigation. Variations in mechanical properties were observed in the concrete used for slab-column connections, but due to material heterogeneity, they could not solely be attributed to the use of RCA. Using concrete with 100% RCA reduced in 5.6% and 12.6% the punching strength of slabs without and with shear reinforcement. The load-displacement response and the cracking pattern of the slab-column connections were not affected by the use of 100% RCA.
1 January 2025 in Revista IBRACON de Estruturas e Materiais
The design of concrete structural elements with discontinuous stress distribution is often done using strut and tie models and involves the design and detailing of reinforcement, as well as verifying the strength of struts and nodal zones. Simplified design approaches restrict the effective stress on a strut below design limits, depending on the strut efficiency factor, established based on the experimental evidence available, comprising tests on full-scale structural members and partially loaded concrete prisms. This paper presents the results of tests on reinforced concrete deep beams and partially loaded hexagonal concrete struts to investigate the strut efficiency factor of bottle-shaped struts. The similarities and differences in terms of response and resistance are discussed. Results show significant differences in behaviour and strut efficiency factor between the hexagonal local models compared to tests on deep beams, evidencing that local models are not representative of the strength of bottle-shaped struts of full-scale reinforced concrete structural members.
PBuscando avaliar a influência da ancoragem na resistência à flexão de vigas reforçadas com mantas de Polímero Reforçado com Fibra de Carbono (PRFC), foram analisados os resultados experimentais de 126 ensaios presentes na literatura e de uma série inédita, ensaiada pelos autores, com 4 vigas de concreto armado. São avaliados os parâmetros que afetam o desempenho e a resistência das vigas, e discutidos os critérios de dimensionamento do fib Bulletin 14 (2001) e ACI 440-2R (2008). Observou-se que, mesmo com dispositivos auxiliares na ancoragem do PRFC, falhas prematuras são possíveis, e também que ambas as recomendações teóricas conduzem a estimativas a favor da segurança, porém excessivamente conservadoras nos casos onde a ancoragem da manta de PRFC é feita adequadamente.
1 January 2024 in Revista IBRACON de Estruturas e Materiais
Shear connectors are essential elements in composite structures of steel and concrete as they ensure the interaction between materials and the transfer of forces. In this research, seven models of shear connectors made from bent CA-50 steel bars were tested. The models varied in bar diameter, reinforcement ratio, and inclination relative to the metal profile’s flange. The results showed that the connector with a 12.5 mm diameter (model A1) exhibited the best performance in terms of strength and ductility. Connectors with a 10.0 mm diameter (models B1 and B2) also showed satisfactory results. The inclination of the connectors did not significantly influence the strength of the models. However, a higher tendency for uplift strain was exhibited in the inclined connectors.