Punching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008) and incorporated the new fib Model Code (2010).
In reinforced concrete flat slab buildings, the transference of unbalanced moments in the slab–column connections usually results from the asymmetry of spans, vertical loads, and horizontal forces from the wind. The punching strength of the slab–column connections can limit the load-carrying capacity of the structure in these cases, leading to structural collapse. The design code provisions are still based on empirical or semi-empirical equations; as the punching shear failure mechanisms are complex, and the ultimate strength is affected by several parameters. In this context, this paper presents the results of the computational investigation of the mechanical behaviour of flat slabs subjected to balanced and unbalanced moments using numerical Finite Element models. The numerical models were calibrated and accurately reproduced the behaviour and the punching resistance for concentric and eccentric loading. Furthermore, a parametric study was conducted to evaluate the mechanical behaviour of flat slabs under different load eccentricities, confirming that the increase in the unbalanced moment negatively impacts the load-carrying capacity of the slab–column connection. Furthermore, it was observed that all computational results obtained from models with unbalanced bending moments were higher than those estimated by the design codes.
The hybridisation of fibre-reinforced polymers (FRPs), particularly with the combination of natural and synthetic fibres, is a prominent option for their development. In the context of the construction industry, there is a notable gap in research on the use of jute and glass fibres for the strengthening of concrete structures. This paper presents comprehensive experimental results from tests on seven reinforced concrete (RC) beams strengthened for shear using synthetic, natural, and hybrid jute–glass FRP composites. The beams were reinforced using the externally bonded reinforcement (EBR) technique with U-wrap bonding. A beam without any strengthening was tested and set as a reference for the other beams. Two beams were tested with synthetic FRP shear strengthenings, one with carbon fibre-reinforced polymer (CFRP) and another with glass fibre-reinforced polymer (GFRP). The remaining tests were on RC beams strengthened with natural jute fibre-reinforced polymer (JFRP) and hybrid jute–glass FRP. The paper discusses the experimental behaviour of the tested beams in terms of vertical displacements, crack widths, and strains on steel bars, concrete, and FRP. The experimental strengths are also compared with theoretical estimates obtained using ACI 440.2R and fib Bulletin 90. The tests confirm the effectiveness of natural jute FRP and jute–glass hybrid FRP as an option for the shear strengthening of reinforced concrete beams.
1 December 2016 in Latin American Journal of Solids and Structures