Luamim Sales Tapajós

Luamim Sales Tapajós

Auto-generated profile, based on publicly available information

Luamim Sales Tapajós

Universidade Federal do Oeste do Pará – UFOPA, Brasil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
RPRosângela Silva Pinto
Rosângela Silva Pinto
VSVanessa Carolaine Sousa
Vanessa Carolaine Sousa
LTLuamim Sales Tapajós
Luamim Sales Tapajós
MFMauricio de Pina Ferreira
Mauricio de Pina Ferreira
ANAarão Ferreira Lima Neto
Aarão Ferreira Lima Neto
This paper presents the results of seven experimental tests in reinforced concrete wide beams, aiming to investigate their performance when subjected to shear, using prefabricated truss stirrups as shear reinforcement, as well as a supplementary reinforcement to control cracks by delamination. The main analysed variables were: position of the supplementary reinforcement, inclination of the shear reinforcement, and spacing between stirrups. Results showed that strength increments of up to 142% were obtained using the prefabricated truss stirrups. Furthermore, the experimental results were compared with the theoretical shear strength estimates of the tested beams, following the recommendations of NBR 6118 (2014), Eurocode 2 (2004), and ACI 318 (2014), in order to evaluate the safety level of these codes when designing concrete elements subjected to shear with the reinforcement used in this paper.

1 January 2023 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
DSDiego Ferreira de Souza
Diego Ferreira de Souza
JAJedson Henryque Correa Abrantes
Jedson Henryque Correa Abrantes
LTLuamim Sales Tapajós
Luamim Sales Tapajós
MFMauricio de Pina Ferreira
Mauricio de Pina Ferreira
ANAarão Ferreira Lima Neto
Aarão Ferreira Lima Neto
Reinforced concrete elements with a high longitudinal and transverse reinforcement ratio may present conflicts on both of them, resulting in reduced labor productivity and a poor job when assembling the transversal reinforcement, reducing its effectiveness. Thus, this research presents a type of internal transverse reinforcement as an alternative to mitigate this conflict between the transverse and longitudinal bars. A total of 5 reinforced concrete wide beams were made, one of them as a reference with closed stirrups, and the other ones with internal stirrups, varying the inclination of the internal transverse reinforcement in 60° and 90°, and the number of vertical legs of the internal transverse reinforcement used. Comparing the results of the beams with internal stirrups with the reference beam, it was observed that the internal stirrups provided increases of up to 14% in shear strength when compared with the closed stirrup.

1 July 2025 in Structures
Verified
Journal Article
Closed access
LTLuamim Sales Tapajós
Luamim Sales Tapajós
MFManoel José Mangabeira Pereira Filho
Manoel José Mangabeira Pereira Filho
ANAarão Ferreira Lima Neto
Aarão Ferreira Lima Neto
MMMarília Gonçalves Marques
Marília Gonçalves Marques
MFMaurício de Pina Ferreira
Maurício de Pina Ferreira

30 December 2018 in Revista ALCONPAT
Verified
Journal Article
Open access
MFMauricio de Pina Ferreira
Mauricio de Pina Ferreira
MOMarcos Honorato de Oliveira
Marcos Honorato de Oliveira
ANAarão Ferreira Lima Neto
Aarão Ferreira Lima Neto
LTLuamim Sales Tapajós
Luamim Sales Tapajós
ANAlex Nascimento
Alex Nascimento
MFMarília Caires Freire
Marília Caires Freire
PBuscando avaliar a influência da ancoragem na resistência à flexão de vigas reforçadas com mantas de Polímero Reforçado com Fibra de Carbono (PRFC), foram analisados os resultados experimentais de 126 ensaios presentes na literatura e de uma série inédita, ensaiada pelos autores, com 4 vigas de concreto armado. São avaliados os parâmetros que afetam o desempenho e a resistência das vigas, e discutidos os critérios de dimensionamento do fib Bulletin 14 (2001) e ACI 440-2R (2008). Observou-se que, mesmo com dispositivos auxiliares na ancoragem do PRFC, falhas prematuras são possíveis, e também que ambas as recomendações teóricas conduzem a estimativas a favor da segurança, porém excessivamente conservadoras nos casos onde a ancoragem da manta de PRFC é feita adequadamente.