Bohyoung Kim

Bohyoung Kim

Auto-generated profile, based on publicly available information

Bohyoung Kim

Division of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Republic of Korea

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SJSeung Hyuck Jeon
Seung Hyuck Jeon
CSChanghoon Song
Changhoon Song
ECEui Kyu Chie
Eui Kyu Chie
BKBohyoung Kim
Bohyoung Kim
YKYoung Hoon Kim
Young Hoon Kim
JKJae-Sung Kim
Jae-Sung Kim
To develop and compare delta-radiomics signatures from 2- (2D) and 3-dimensional (3D) features that predict treatment outcomes following preoperative chemoradiotherapy (CCRT) and surgery for locally advanced rectal cancer. In total, 101 patients (training cohort, n = 67; validation cohort, n = 34) with locally advanced rectal adenocarcinoma between 2008 and 2015 were included. We extracted 55 features from T2-weighted magnetic resonance imaging (MRI) scans. Delta-radiomics feature was defined as the difference in radiomics feature before and after CCRT. Signatures were developed to predict local recurrence (LR), distant metastasis (DM), and disease-free survival (DFS) from 2D and 3D features. The least absolute shrinkage and selection operator regression was used to select features and build signatures. The delta-radiomics signatures and clinical factors were integrated into Cox regression analysis to determine if the signatures were independent prognostic factors. The radiomics signatures for LR, DM, and DFS were developed and validated using both 2D and 3D features. Outcomes were significantly different in the low- and high-risk patients dichotomized by optimal cutoff in both the training and validation cohorts. In multivariate analysis, the signatures were independent prognostic factors even when considering the clinical parameters. There were no significant differences in C-index from 2D vs. 3D signatures. This is the first study to develop delta-radiomics signatures for rectal cancer. The signatures successfully predicted the outcomes and were independent prognostic factors. External validation is warranted to ensure their performance.

13 October 2020 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Open access
YKYoungtaek Kim
Youngtaek Kim
JKJaeyoung Kim
Jaeyoung Kim
HJHyeon Jeon
Hyeon Jeon
YKYoung-Ho Kim
Young-Ho Kim
HSHyunjoo Song
Hyunjoo Song
JSJinwook Seo
Jinwook Seo
Git metadata contains rich information for developers to understand the overall context of a large software development project. Thus it can help new developers, managers, and testers understand the history of development without needing to dig into a large pile of unfamiliar source code. However, the current tools for Git visualization are not adequate to analyze and explore the metadata: They focus mainly on improving the usability of Git commands instead of on helping users understand the development history. Furthermore, they do not scale for large and complex Git commit graphs, which can play an important role in understanding the overall development history. In this paper, we present Githru, an interactive visual analytics system that enables developers to effectively understand the context of development history through the interactive exploration of Git metadata. We design an interactive visual encoding idiom to represent a large Git graph in a scalable manner while preserving the topological structures in the Git graph. To enable scalable exploration of a large Git commit graph, we propose novel techniques (graph reconstruction, clustering, and Context-Preserving Squash Merge (CSM) methods) to abstract a large-scale Git commit graph. Based on these Git commit graph abstraction techniques, Githru provides an interactive summary view to help users gain an overview of the development history and a comparison view in which users can compare different clusters of commits. The efficacy of Githru has been demonstrated by case studies with domain experts using real-world, in-house datasets from a large software development team at a major international IT company. A controlled user study with 12 developers comparing Githru to previous tools also confirms the effectiveness of Githru in terms of task completion time.

24 September 2024 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
JKJaeyoung Kim
Jaeyoung Kim
SLSihyeon Lee
Sihyeon Lee
HJHyeon Jeon
Hyeon Jeon
KLKeon-Joo Lee
Keon-Joo Lee
HBHee-Joon Bae
Hee-Joon Bae
JSJinwook Seo
Jinwook Seo
Acute stroke demands prompt diagnosis and treatment to achieve optimal patient outcomes. However, the intricate and irregular nature of clinical data associated with acute stroke, particularly blood pressure (BP) measurements, presents substantial obstacles to effective visual analytics and decision-making. Through a year-long collaboration with experienced neurologists, we developed PhenoFlow, a visual analytics system that leverages the collaboration between human and Large Language Models (LLMs) to analyze the extensive and complex data of acute ischemic stroke patients. PhenoFlow pioneers an innovative workflow, where the LLM serves as a data wrangler while neurologists explore and supervise the output using visualizations and natural language interactions. This approach enables neurologists to focus more on decision-making with reduced cognitive load. To protect sensitive patient information, PhenoFlow only utilizes metadata to make inferences and synthesize executable codes, without accessing raw patient data. This ensures that the results are both reproducible and interpretable while maintaining patient privacy. The system incorporates a slice-and-wrap design that employs temporal folding to create an overlaid circular visualization. Combined with a linear bar graph, this design aids in exploring meaningful patterns within irregularly measured BP data. Through case studies, PhenoFlow has demonstrated its capability to support iterative analysis of extensive clinical datasets, reducing cognitive load and enabling neurologists to make well-informed decisions. Grounded in long-term collaboration with domain experts, our research demonstrates the potential of utilizing LLMs to tackle current challenges in data-driven clinical decision-making for acute ischemic stroke patients.

4 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
YDYoon Ah Do
Yoon Ah Do
MJMijung Jang
Mijung Jang
BYBo La Yun
Bo La Yun
SSSung Ui Shin
Sung Ui Shin
BKBohyoung Kim
Bohyoung Kim
SKSun Mi Kim
Sun Mi Kim
The present study evaluated the diagnostic performance of artificial intelligence-based computer-aided diagnosis (AI-CAD) compared to that of dedicated breast radiologists in characterizing suspicious microcalcification on mammography. We retrospectively analyzed 435 unilateral mammographies from 420 patients (286 benign; 149 malignant) undergoing biopsy for suspicious microcalcification from June 2003 to November 2019. Commercial AI-CAD was applied to the mammography images, and malignancy scores were calculated. Diagnostic performance was compared between radiologists and AI-CAD using the area under the receiving operator characteristics curve (AUC). The AUCs of radiologists and AI-CAD were not significantly different (0.722 vs. 0.745, p = 0.393). The AUCs of the adjusted category were 0.726, 0.744, and 0.756 with cutoffs of 2%, 10%, and 38.03% for AI-CAD, respectively, which were all significantly higher than those for radiologists alone (all p < 0.05). None of the 27 cases downgraded to category 3 with a cutoff of 2% were confirmed as malignant on pathological analysis, suggesting that unnecessary biopsies could be avoided. Our findings suggest that the diagnostic performance of AI-CAD in characterizing suspicious microcalcification on mammography was similar to that of the radiologists, indicating that it may aid in making clinical decisions regarding the treatment of breast microcalcification.

1 July 2017 in Methods
Verified
Journal Article
Closed access
SLSehi L'Yi
Sehi L'Yi
DJDaekyoung Jung
Daekyoung Jung
MOMinsik Oh
Minsik Oh
BKBohyoung Kim
Bohyoung Kim
RFRobert J. Freishtat
Robert J. Freishtat
JSJinwook Seo
Jinwook Seo

1 June 2009 in Radiology
Verified
Journal Article
Closed access
SJSeung-Moon Joo
Seung-Moon Joo
KLKyoung Ho Lee
Kyoung Ho Lee
YKYoung Hoon Kim
Young Hoon Kim
SKSo Yeon Kim
So Yeon Kim
KKKyuseok Kim
Kyuseok Kim
BKBohyoung Kim
Bohyoung Kim
To determine the frequency of normal appendix visualization at low-dose (LD) unenhanced computed tomography (CT) performed with a 16- or 64-detector row scanner when images are reviewed by using the sliding slab averaging technique.The institutional review board approved the study and waived the informed consent requirement. A total of 259 patients, 37 (14.3%) of whom had previously undergone appendectomy, underwent LD unenhanced CT (mean effective dose, 1.7 mSv) performed with a 16- or 64-detector row scanner to assess urinary colic. Three readers used the sliding slab averaging technique to retrospectively review the thin-section (0.67- or 2.00-mm section thickness) images and grade the appendix as absent, unsurely or partly visualized, or clearly and entirely visualized. Interobserver agreement was measured with weighted kappa statistics. McNemar tests were used to compare sensitivity between the readers. Logistic regression analysis was performed to assess the effects of body mass index, patient sex, and type of CT scanner on appendiceal visualization.The kappa statistics for each reader pair were as follows: 0.97 for agreement between readers 1 and 2, 0.93 for agreement between readers 2 and 3, and 0.92 for agreement between readers 1 and 3. Each reader clearly identified the entire appendix in 213 (96.0%), 209 (94.1%), and 205 (92.3%) of the 222 patients without a history of appendectomy. When unsurely or partly visualized appendices were included, the frequencies increased to 99.1% (n = 220), 98.7% (n = 219), and 97.3% (n = 216), respectively, for readers 1, 2, and 3. These frequencies rarely differed between the readers. (P values ranged from .021 to greater than .99.) The three readers consistently reported that the appendix was not visualized in the 37 patients who had undergone appendectomy. None of the tested variables significantly affected appendix visualization.Most normal appendices are visualized on thin-section LD unenhanced CT images reviewed with the sliding slab averaging technique.