Xin Wei

Xin Wei

Auto-generated profile, based on publicly available information

Xin Wei

Cybernetics and Reality Engineering Laboratory, Nara Institute of Science and Technology, Ikoma, Nara, Japan

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHuakun Liu
Huakun Liu
XWXin Wei
Xin Wei
MPMonica Perusquia-Hernandez
Monica Perusquia-Hernandez
NINaoya Isoyama
Naoya Isoyama
HUHideaki Uchiyama
Hideaki Uchiyama
KKKiyoshi Kiyokawa
Kiyoshi Kiyokawa
This paper presents a deep data-driven inertial measurement unit (IMU) online calibration (DUET) method that can compensate for the run-time errors of the accelerometer and gyroscope to improve inertial-based odometry. We design a differential error learning strategy based on the kinematic motion model to train the sensor error compensation model. This strategy allows our method to learn IMU sensor errors, such as scale factors, axis-misalignment, and biases, solely from displacement and orientation increments given by external tracking systems. Then during the odometry computation, the trained model leverages the past inertial data to mitigate the sensor errors and thus reduces the integration errors to reflect the odometry state. The experiments conducted on two public visual-inertial datasets show an average of 20% improvement in the position estimation accuracy of visual-inertial odometry, which is comparable to existing learning-based methods with lower operational complexity.

19 April 2011 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
XWX. Wei
X. Wei
YPY. Peng
Y. Peng
WWW. Wang
W. Wang
XCX. Chen
X. Chen
DLD. Li
D. Li

25 June 2025 in Royal Society Open Science
Verified
Journal Article
Open access
NCNicholas A. Coles
Nicholas A. Coles
BPBartosz Perz
Bartosz Perz
MBMaciej Behnke
Maciej Behnke
JEJohannes C. Eichstaedt
Johannes C. Eichstaedt
Soo-Hyung KimSoo-Hyung Kim
Soo-Hyung Kim
Stanislaw SaganowskiStanislaw Saganowski
Stanislaw Saganowski
Researchers are increasingly using machine learning to study physiological markers of emotion. We evaluated the promises and limitations of this approach via a big team science competition. Twelve teams competed to predict self-reported affective experiences using a multi-modal set of peripheral nervous system measures. Models were trained and tested in multiple ways: with data divided by participants, targeted emotion, inductions, and time. In 100% of tests, teams outperformed baseline models that made random predictions. In 46% of tests, teams also outperformed baseline models that relied on the simple average of ratings from training datasets. More notably, results uncovered a methodological challenge: multiplicative constraints on generalizability. Inferences about the accuracy and theoretical implications of machine learning efforts depended not only on their architecture, but also how they were trained, tested, and evaluated. For example, some teams performed better when tested on observations from the same (vs. different) subjects seen during training. Such results could be interpreted as evidence against claims of universality. However, such conclusions would be premature because other teams exhibited the opposite pattern. Taken together, results illustrate how big team science can be leveraged to understand the promises and limitations of machine learning methods in affective science and beyond.

4 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
XWXin Wei
Xin Wei
FDFelix Dollack
Felix Dollack
KKKiyoshi Kiyokawa
Kiyoshi Kiyokawa
MPMonica Perusquia-Hernandez
Monica Perusquia-Hernandez
Eye movement is an important tool used to investigate cognition. It also serves as input in human–computer interfaces for assistive technology. It can be measured with camera-based eye tracking and electro-oculography (EOG). EOG does not rely on eye visibility and can be measured even when the eyes are closed. We investigated the feasibility of detecting the gaze direction using EOG while having the eyes closed. A total of 15 participants performed a proprioceptive calibration task with open and closed eyes, while their eye movement was recorded with a camera-based eye tracker and with EOG. The calibration was guided by the participants’ hand motions following a pattern of felt dots on cardboard. Our cross-correlation analysis revealed reliable temporal synchronization between gaze-related signals and the instructed trajectory across all conditions. Statistical comparison tests and equivalence tests demonstrated that EOG tracking was statistically equivalent to the camera-based eye tracker gaze direction during the eyes-open condition. The camera-based eye-tracking glasses do not support tracking with closed eyes. Therefore, we evaluated the EOG-based gaze estimates during the eyes-closed trials by comparing them to the instructed trajectory. The results showed that EOG signals, guided by proprioceptive cues, followed the instructed path and achieved a significantly greater accuracy than shuffled control data, which represented a chance-level performance. This demonstrates the advantage of EOG when camera-based eye tracking is infeasible, and it paves the way for the development of eye-movement input interfaces for blind people, research on eye movement direction when the eyes are closed, and the early detection of diseases.

12 October 2025
Verified
Conference Paper
Open access
HLHuakun Liu
Huakun Liu
MCMiao Cheng
Miao Cheng
XWXin Wei
Xin Wei
FDFelix Dollack
Felix Dollack
VSVictor Schneider
Victor Schneider
MPMonica Perusquia-Hernandez
Monica Perusquia-Hernandez

12 January 2026 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
XWXin Wei
Xin Wei
HLHuakun Liu
Huakun Liu
YHYutaro Hirao
Yutaro Hirao
MPMonica Perusquia-Hernandez
Monica Perusquia-Hernandez
KMKatsutoshi Masai
Katsutoshi Masai
KKKiyoshi Kiyokawa
Kiyoshi Kiyokawa
Early detection of visual impairments remains a persistent challenge, especially due to the subtle and often unnoticed nature of early-stage symptoms. Recent works have attempted to transition clinical tests to home-based services or develop innovative diagnostic methods, but most approaches remain self-initiated and discrete. In this study, we focused on refractive disorders and explored the feasibility of using electrooculography (EOG) to detect changes in refractive power passively. Thirty-nine participants used optometry trial lenses to simulate different refractive conditions. Participants performed a series of visual tasks while their EOG signals were recorded. We trained classification models to predict simulated refractive power levels relative to baseline visual condition across multiple evaluation settings, including within-subject, temporal generalization, and across-subject scenarios. The findings reveal that refractive power classification models achieve a mean accuracy of $0.950 \pm 0.034$ in within-subject, within-condition scenarios. Within-subject models tested on data from a different time point showed highly variable performance. While some participants achieved promising results, overall accuracy remained low, with a mean of $0.159 \pm 0.285$. We employed three strategies to evaluate the across-subject models. Naive models performed poorly ($0.161 \pm 0.063$) and linear normalization provided limited improvement ($0.175 \pm 0.062$). However, the fine-tuning strategy substantially improved the model's performance ($0.785 \pm 0.123$). EOG signals contain useful information for refractive power classification, particularly in personalized contexts. However, generalizing across time and individuals remains challenging. Overall, this work offers valuable insights for advancing EOG-based systems aimed at passive, real-time monitoring of visual conditions.