Ionizing radiation acoustic imaging (iRAI) allows online monitoring of radiation’s interactions with tissues during radiation therapy, providing real-time, adaptive feedback for cancer treatments. We describe an iRAI volumetric imaging system that enables mapping of the three-dimensional (3D) radiation dose distribution in a complex clinical radiotherapy treatment. The method relies on a two-dimensional matrix array transducer and a matching multi-channel preamplifier board. The feasibility of imaging temporal 3D dose accumulation was first validated in a tissue-mimicking phantom. Next, semiquantitative iRAI relative dose measurements were verified in vivo in a rabbit model. Finally, real-time visualization of the 3D radiation dose delivered to a patient with liver metastases was accomplished with a clinical linear accelerator. These studies demonstrate the potential of iRAI to monitor and quantify the 3D radiation dose deposition during treatment, potentially improving radiotherapy treatment efficacy using real-time adaptive treatment.
The lack of a non-invasive or minimally invasive imaging technique has long been a challenge to investigating brain activities in mice. Functional magnetic resonance imaging and the more recently developed diffuse optical imaging both suffer from limited spatial resolution. Photoacoustic (PA) imaging combines the sensitivity of optical excitation to hemodynamic changes and ultrasound detection's relatively high spatial resolution. In this study, we evaluated the feasibility of using a label-free, real-time PA computed tomography (PACT) system to measure visually evoked hemodynamic responses within the primary visual cortex (V1) in mice. Photostimulation of the retinas evoked significantly faster and stronger V1 responses in wild-type mice than in age-matched rod/cone-degenerate mice, consistent with known differences between rod/cone- vs. melanopsin-mediated photoreception. In conclusion, the PACT system in this study has sufficient sensitivity and spatial resolution to resolve visual cortical hemodynamics during retinal photostimulation, and PACT is a potential tool for investigating visually evoked brain activities in mouse models of retinal diseases.
This study investigates the feasibility of capturing visually evoked hemodynamic responses in the mouse brain using photoacoustic tomography (PAT) and ultrasound (US) dual-modality imaging. A commercial piezoelectric transducer array and a capacitive micromachined ultrasonic transducer (CMUT) array were compared using a programmable PAT-US imaging system. The system resolution was measured by imaging phantoms. We also tested the ability of the system to capture visually evoked hemodynamic responses in the superior colliculus as well as the primary visual cortex in wild-type mice. Results show that the piezoelectric transducer array and the CMUT array exhibit comparable imaging performance, and both arrays can capture visually evoked hemodynamic responses in subcortical as well as cortical regions of the mouse brain.
SignificanceMany techniques exist for screening retinal phenotypes in mouse models in vision research, but significant challenges remain for efficiently probing higher visual centers of the brain. Photoacoustic computed tomography (PACT), with optical sensitivity to hemodynamic response (HR) in brain and ultrasound resolution, provides unique advantages in comprehensively assessing higher visual function in the mouse brain.AimWe aim to examine the reliability of PACT in the functional phenotyping of mouse models for vision research.ApproachA PACT-ultrasound (US) parallel imaging system was established with a one-dimensional (1D) US transducer array and a tunable laser. Imaging was performed at three coronal planes of the brain, covering the primary visual cortex and the four subcortical nuclei, including the superior colliculus, the dorsal lateral geniculate nucleus, the suprachiasmatic nucleus, and the olivary pretectal nucleus. The visual-evoked HR was isolated from background signals using an impulse-based data processing protocol. rd1 mice with rod/cone degeneration, melanopsin-knockout (mel-KO) mice with photoreceptive ganglion cells that lack intrinsic photosensitivity, and wild-type mice as controls were imaged. The quantitative characteristics of the visual-evoked HR were compared.ResultsQuantitative analysis of the HRs shows significant differences among the three mouse strains: (1) rd1 mice showed both smaller and slower responses compared with wild type (n=10,10, p<0.01) and (2) mel-KO mice had lower amplitude but not significantly delayed photoresponses than wild-type mice (n=10,10, p<0.01). These results agree with the known visual deficits of the mouse strains.ConclusionsPACT demonstrated sufficient sensitivity to detecting post-retinal functional deficits.
Gas sensors with good performance should exhibit characteristics such as high sensitivity, low energy consumption, and low fabrication costs. A metal-oxide semiconductor material, amorphous indium-gallium-zinc-oxide (InGaZnO4, has a good stability-IGZO), is with potential for use in gas sensor. It can be used for continuously measurement of the gas content. To obtain more sensitivity, parameters of UV light is measured. The sensitivity is significantly improved at low light intensity. And stability was also determined, that reduce the light intensity does not reduce the stability of sensors.