Dosil Pereira de Jesus

Dosil Pereira de Jesus

Auto-generated profile, based on publicly available information

Dosil Pereira de Jesus

Institute of Chemistry, State University of Campinas (UNICAMP), Campinas, 13083-970, Brazil

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2011 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
WCWendell Coltro
Wendell Coltro
RLRenato Sousa Lima
Renato Sousa Lima
TSThiago Pinotti Segato
Thiago Pinotti Segato
Emanuel CarrilhoEmanuel Carrilho
Emanuel Carrilho
DJDosil Pereira de Jesus
Dosil Pereira de Jesus
José Alberto Fracassi da SilvaJosé Alberto Fracassi da Silva
José Alberto Fracassi da Silva
The use of capacitively coupled contactless conductivity detection (C4D) on miniaturized systems has increased considerably over the last few years. Since the first report, 10 years ago, several advances on the detection cell geometry, strategies for increasing the sensitivity and a wide range of applications have been reported. This review intends to cover the main features related to the instrumental setup of this detection method for analytical and bioanalytical assays on microfluidic chips.

19 May 2014 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
WCWendell Coltro
Wendell Coltro
CCChao‐Min Cheng
Chao‐Min Cheng
Emanuel CarrilhoEmanuel Carrilho
Emanuel Carrilho
DJDosil Pereira de Jesus
Dosil Pereira de Jesus

23 July 2010 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
WCWendell Coltro
Wendell Coltro
DJDosil Pereira de Jesus
Dosil Pereira de Jesus
José Alberto Fracassi da SilvaJosé Alberto Fracassi da Silva
José Alberto Fracassi da Silva
Claudimir Lucio do LagoClaudimir Lucio do Lago
Claudimir Lucio do Lago
Emanuel CarrilhoEmanuel Carrilho
Emanuel Carrilho

30 July 2021 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RQReverson Fernandes Quero
Reverson Fernandes Quero
GSGéssica Domingos da Silveira
Géssica Domingos da Silveira
José Alberto Fracassi da SilvaJosé Alberto Fracassi da Silva
José Alberto Fracassi da Silva
DJDosil Pereira de Jesus
Dosil Pereira de Jesus
Theoretical and experimental studies showed that FDM 3D printers can be optimized to fabricate microfluidic devices with high resolution and transparency.

9 January 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
LBLucas P. Bressan
Lucas P. Bressan
CACristina B. Adamo
Cristina B. Adamo
RQReverson F. Quero
Reverson F. Quero
DJDosil P. de Jesus
Dosil P. de Jesus
José Alberto Fracassi da SilvaJosé Alberto Fracassi da Silva
José Alberto Fracassi da Silva
Fused deposition modeling (FDM) is the lowest cost 3D-printing technology and has found application in microfluidics in the past few years. However, it lacks resolution and the ability to print transparent windows for optical detection. For this reason, we present a simple protocol to prepare 3D-printed microfluidic channels around 170 μm width and transparent windows using a 0.2 mm nozzle, poly(methyl methacrylate) (PMMA) as the transparent substrate and poly(lactic acid) (PLA) as the polymer filament. Due to the similar molecular structure of PLA and PMMA, outstanding bonding was achieved. After optimization of the printing settings, we found that a gap of 200 μm between the PMMA slide and the nozzle results in channels that present no leakage even with high flow rates of up to 2 mL min−1. As a proof of concept, we present bioanalytical applications for devices produced with this protocol, such as determination of nitrite, total proteins and nitric oxide, as well as microorganism visualization. We believe that this protocol can simplify the production of low-cost microfluidic devices containing transparent detection windows since it does not require tapes or glues, nor stopping the printing process to insert other materials, such as glass.