Omer Burak Demirel

Omer Burak Demirel

Auto-generated profile, based on publicly available information

Omer Burak Demirel

Department of Electrical and Computer Engineering University of Minnesota Minneapolis Minnesota USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ODOmer Burak Demirel
Omer Burak Demirel
BYBurhaneddin Yaman
Burhaneddin Yaman
CSChetan Shenoy
Chetan Shenoy
SMSteen Moeller
Steen Moeller
SWSebastian Weingärtner
Sebastian Weingärtner
MAMehmet Akcakaya
Mehmet Akcakaya
Purpose: To develop a physics‐guided deep learning (PG‐DL) reconstruction strategy based on a signal intensity informed multi‐coil (SIIM) encoding operator for highly‐accelerated simultaneous multislice (SMS) myocardial perfusion cardiac MRI (CMR).Methods: First‐pass perfusion CMR acquires highly‐accelerated images with dynamically varying signal intensity/SNR following the administration of a gadolinium‐based contrast agent. Thus, using PG‐DL reconstruction with a conventional multi‐coil encoding operator leads to analogous signal intensity variations across different time‐frames at the network output, creating difficulties in generalization for varying SNR levels. We propose to use a SIIM encoding operator to capture the signal intensity/SNR variations across time‐frames in a reformulated encoding operator. This leads to a more uniform/flat contrast at the output of the PG‐DL network, facilitating generalizability across time‐frames. PG‐DL reconstruction with the proposed SIIM encoding operator is compared to PG‐DL with conventional encoding operator, split slice‐GRAPPA, locally low‐rank (LLR) regularized reconstruction, low‐rank plus sparse (L + S) reconstruction, and regularized ROCK‐SPIRiT.Results: Results on highly accelerated free‐breathing first pass myocardial perfusion CMR at three‐fold SMS and four‐fold in‐plane acceleration show that the proposed method improves upon the reconstruction methods use for comparison. Substantial noise reduction is achieved compared to split slice‐GRAPPA, and aliasing artifacts reduction compared to LLR regularized reconstruction, L + S reconstruction and PG‐DL with conventional encoding. Furthermore, a qualitative reader study indicated that proposed method outperformed all methods.Conclusion: PG‐DL reconstruction with the proposed SIIM encoding operator improves generalization across different time‐frames /SNRs in highly accelerated perfusion CMR.

1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
AOA A Ozaslan
A A Ozaslan
AAAhmet Alacaoglu
Ahmet Alacaoglu
ODOmer Burak Demirel
Omer Burak Demirel
TÇTolga Çukur
Tolga Çukur
ESEmine Ulku Saritas
Emine Ulku Saritas
Magnetic particle imaging (MPI) is a fast emerging biomedical imaging modality that exploits the nonlinear response of superparamagnetic iron oxide (SPIO) nanoparticles to image their spatial distribution. Previously, various scanning trajectories were analyzed for the system function reconstruction (SFR) approach, providing important insight regarding their image quality performances. While Cartesian trajectories remain the most popular choice for x-space-based reconstruction, recent work suggests that non-Cartesian trajectories such as the Lissajous trajectory may prove beneficial for improving image quality. In this work, we propose a generalized reconstruction scheme for x-space MPI that can be used in conjunction with any scanning trajectory. The proposed technique automatically tunes the reconstruction parameters from the scanning trajectory, and does not induce any additional blurring. To demonstrate the proposed technique, we utilize five different trajectories with varying density levels. Comparison to alternative reconstruction methods show significant improvement in image quality achieved by the proposed technique. Among the tested trajectories, the Lissajous and bidirectional Cartesian trajectories prove more favorable for x-space MPI, and the resolution of the images from these two trajectories can further be improved via deblurring. The proposed fully automated gridding reconstruction can be utilized with these trajectories to improve the image quality in x-space MPI.

10 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ODOmer Burak Demirel
Omer Burak Demirel
SWSebastian Weingärtner
Sebastian Weingärtner
SMSteen Moeller
Steen Moeller
MAMehmet Akcakaya
Mehmet Akcakaya

21 January 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
TKToygan Kilic
Toygan Kilic
PLPatrick Alexander Liebig
Patrick Alexander Liebig
ODOmer Burak Demirel
Omer Burak Demirel
JHJürgen Herrler
Jürgen Herrler
ANArmin M. Nagel
Armin M. Nagel
MAMehmet Akcakaya
Mehmet Akcakaya
Purpose: To mitigate inhomogeneity at 7T for multi‐channel transmit arrays using unsupervised deep learning with convolutional neural networks (CNNs).Methods: Deep learning parallel transmit (pTx) pulse design has received attention, but such methods have relied on supervised training and did not use CNNs for multi‐channel maps. In this work, we introduce an alternative approach that facilitates the use of CNNs with multi‐channel maps while performing unsupervised training. The multi‐channel maps are concatenated along the spatial dimension to enable shift‐equivariant processing amenable to CNNs. Training is performed in an unsupervised manner using a physics‐driven loss function that minimizes the discrepancy of the Bloch simulation with the target magnetization, which eliminates the calculation of reference transmit RF weights. The training database comprises 3824 2D sagittal, multi‐channel maps of the healthy human brain from 143 subjects. data were acquired at 7T using an 8Tx/32Rx head coil. The proposed method is compared to the unregularized magnitude least‐squares (MLS) solution for the target magnetization in static pTx design.Results: The proposed method outperformed the unregularized MLS solution for RMS error and coefficient‐of‐variation and had comparable energy consumption. Additionally, the proposed method did not show local phase singularities leading to distinct holes in the resulting magnetization unlike the unregularized MLS solution.Conclusion: Proposed unsupervised deep learning with CNNs performs better than unregularized MLS in static pTx for speed and robustness.

21 July 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ÖDÖmer Burak Demirel
Ömer Burak Demirel
SWSebastian Weingärtner
Sebastian Weingärtner
SMSteen Moeller
Steen Moeller
MAMehmet Akcakaya
Mehmet Akcakaya
The aim of this study is to develop and evaluate a regularized Simultaneous Multi-Slice (SMS) reconstruction method for improved Cardiac Magnetic Resonance Imaging (CMR). The proposed reconstruction method, SMS with COmpOsition of k-space IntErpolations (SMS-COOKIE) combines the advantages of Iterative Self-consistent Parallel Imaging Reconstruction (SPIRiT) and split slice-Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA), while allowing regularization for further noise reduction. The proposed SMS-COOKIE was implemented with and without regularization, and validated using a Saturation Pulse-Prepared Heart rate Independent inversion REcovery (SAPPHIRE) myocardial T1 mapping sequence. The performance of the proposed reconstruction method was compared to ReadOut (RO)–SENSE-GRAPPA and split slice-GRAPPA, on both retrospectively and prospectively three-fold SMS-accelerated data with an additional two-fold in-plane acceleration. All SMS reconstruction methods yielded similar T1 values compared to single band imaging. SMS-COOKIE showed lower spatial variability in myocardial T1 with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10−4). The proposed method with additional locally low rank (LLR) regularization reduced the spatial variability, again with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10−4). In conclusion, improved reconstruction quality was achieved with the proposed SMS-COOKIE, which also provided lower spatial variability with significant improvement over split slice-GRAPPA.

1 May 2017
Verified
Conference Paper
Closed access
DSDamla Sarica
Damla Sarica
ODOmer Burak Demirel
Omer Burak Demirel
ESEmine Ulku Saritas
Emine Ulku Saritas
Magnetic Particle Imaging (MPI) is a new imaging technology that images the spatial distribution of iron oxide nanoparticles. Since the magnetic field strength that can be safely applied in MPI is limited, the field-of-view (FOV) must be divided into partial FOVs. Because the excitation magnetic field causes direct feedthrough on the receiver coil, the excitation frequency must be filtered out of the MPI signal. During this process, the nanoparticle signal at the same frequency is also lost, as a result of which each partial FOV experiences different levels of DC shift. In the standard MPI image reconstruction, these DC shifts are calculated from neighboring overlapping partial FOVs. Here, we propose a novel method that directly reconstructs the MPI image from the calculated DC shift values. Especially in the case of low bandwidth signal acquisitions, this method yields higher resolution images when compared to the standard method. The simulation results at various signal-to-noise ratios (SNR) show that the proposed method produces 6-8 dB increase in peak SNR and yields images that closely match the ideal image.