21 July 2020 in IEEE Transactions on Industrial Electronics
The on-line detection of incipient faults for permanent magnet synchronous machine (PMSM) has been a great challenge in recent decades, where the fault features are extremely trivial and the machine fault type is normally unknown in advance. An online fault detection and discrimination of incipient faults for PMSM, including stator inter-turn short-circuit and resistive unbalance fault, is proposed in this paper. Firstly, zero-sequence voltage signal is collected and the zero-sequence voltage component (ZSVC) is used to detect the abnormal status of the PMSM. Then, high frequency (HF) signals are injected to the PMSM to discriminate the fault type. It shows that the amplitude of the HF component in ZVSC is proportional to the frequency of the injected signal under inter-turn short-circuit while it is constant under the resistive unbalance fault, and due to this difference, the fault type may be discriminated. Finally, the effectiveness of the theoretical analysis is validated by the simulation and experimental results.
30 November 2022 in IEEE Transactions on Transportation Electrification
The inter-turn short-circuit fault (ITSCF) is a common incipient fault for the permanent magnet synchronous machine (PMSM) drive system. In recent years, the high-resolution ITSCF detection method that combines the high frequency (HF) signal injection and zero-sequence voltage measurement has been put forward. However, for the traditional HF signal injection technique, nonnegligible voltage distortion may occur when the injection frequency is close to the PWM carrier-frequency. In addition, the injected voltage varies with the operating conditions of the PMSM. These drawbacks of the traditional HF signal injection technique greatly limit the ITSCF detection performance using HF signal injection. To further improve the ITSCF detection performance, an improved HF injection scheme is proposed in this paper. In the proposed method, the six active voltage vectors are injected into the PMSM in certain orders to realize a rotating voltage injection, and the injection frequency is up to five-sixth of the PWM carrier-frequency. By employing the proposed injection method, the ITSCF detection sensitivity can be much improved. And the ITSCF detection performance is not affected by the operation conditions of the PMSMs. Finally, the simulations and experiments are carried out to verify the proposed method.
10 August 2021 in IEEE Transactions on Industry Applications
This article proposes a winding condition monitoring scheme for inverter-fed permanent magnet synchronous machine (PMSM) based on high frequency (HF) current injection. By setting specific current references for the HF positive and negative sequence current regulators, HF current can be injected into different phase winding pairs, and then the HF line voltage deviations are extracted for winding condition monitoring. The amplitude of the extracted HF line voltage deviation is defined as the condition indicator to evaluate the condition of phase winding. In the proposed method, the conditions of all phase windings can be separately monitored, where not only inter-turn short-circuit fault (ISF) in one phase but also ISFs in multiple phases can be accurately identified. Simulations and experiments have been carried out to validate the proposed method. It shows that the proposed method has high sensitivity to ISF and negligible sensitivity to the operation conditions of the PMSM.
19 April 2022 in IEEE Transactions on Energy Conversion
Inter-turn short-circuit fault (ISF) is a typical incipient fault of the PMSM, which could be detected by high frequency (HF) signal injection method with high resolution. However, the performance comparisons and key parameter selections for various signal injection methods remain untouched. In this paper, different HF injection signals, including rotating high frequency voltage (RHFV), pulsating high frequency voltage (PHFV) and rotating high frequency current (RHFC), are put forward and compared by extracting the HF fault features in zero-sequence voltage space. Since the RHFV injection method has the advantages of high resolution and simple control structure, the fault features under the RHFV signal injection with different parameters are studied. In order to obtain ISF detection resolution as high as possible, the frequency of the RHFV signal is suggested to be near half the PWM frequency of the PMSM inverter. Simulations and experiments are carried out and the results verify the effectiveness of the theoretical analysis.
8 June 2021 in IEEE Transactions on Industry Applications
In the hybrid modular multilevel converter (MMC), the voltage imbalance between the capacitors of half-bridge submodule (HBSM) and full-bridge submodule (FBSM) would occur when the over-modulation index exceeds certain range, which is caused by the different charging/discharging properties of the HBSM and FBSM. An improved hybrid MMC with self-balancing branch (SBB) is proposed in this article to avoid the voltage imbalance under over-modulation situations. The SBBs could offer additional energy transmitting channel for each bypassed HBSM at the interval of negative arm voltage. Thus, the HBSMs could possess the same energy charging/discharging properties as the FBSMs, and then the voltage imbalance between the HBSM and FBSM capacitors could be avoided under any over-modulation indexes. The operation mechanism of the proposed SBB is revealed in detail, according to which the component parameter in the SBB could be selected. The effectiveness of the proposed hybrid MMC with SBBs is verified by the simulation and experimental results. Also, it shows that the proposed hybrid MMC could realize the voltage balancing under over-modulation situations with lower energy losses according to the comparisons with other MMC topologies.
17 June 2024 in IEEE Transactions on Instrumentation and Measurement
Signal distortions in voltage, current, and speed are caused by inter-turn short-circuit faults (ISF) in permanent magnet synchronous machines (PMSM). At present, researchers mainly select the collected signal according to the experience and it still lacks the theoretical analysis for the signal selection. For this reason, this paper investigates the signal processing for the detection of the ISF in the PMSM. The signals of speed, current and zero sequence voltage are adopted and the fault features of the ISF are acquired. The applicability comparisons of the fault feature for different signals are conducted according to the sensitivity and the signal-to-noise ratio (SNR). Simulations and experiments are done to confirm that the theoretical analysis is correctness. It is found that the 2nd harmonic occurs in the speed signal and q-axis current i q , and the zero-sequence voltage signal adds the fundamental component under the ISF state. From the indexes of SNR and sensitivity, the zero-sequence voltage is the most effective signal for the ISF detection, and the q-axis current i q is better than the speed signal.