Xiaohu Tang

Xiaohu Tang

Auto-generated profile, based on publicly available information

Xiaohu Tang

National Key Laboratory of Microwave Photonics, Nanjing University of Aeronautics and Astronautics, Nanjing, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
TQTing Qing
Ting Qing
SLShupeng Li
Shupeng Li
YFYijie Fang
Yijie Fang
LWLihan Wang
Lihan Wang
XTXiaohu Tang
Xiaohu Tang
SPShilong Pan
Shilong Pan
High-resolution and high-sensitivity optical vector analysis (OVA) is highly desired by many applications, such as optical sensors and photonic integrated circuits (PICs). However, it is difficult to achieve high resolution and high sensitivity simultaneously. Here, we propose and experimentally demonstrate a high sensitivity OVA using coherent detection to achieve the complex frequency responses (including magnitude and phase responses) of a device under test (DUT). Carrier phase noise (CPN) cancellation is employed to eliminate the carrier phase fluctuation induced by the coherent detection. In an experiment, the frequency responses of a fiber Bragg grating (FBG) is accurately measured by the proposed method when the probe light is suppressed by ~18 dB. As a comparison, the method using coherent detection without CPN cancellation can only achieve the magnitude response, and the method using direct detection cannot obtain an effective measurement. The influence of the linewidth and time delay on the measurement is discussed. The proposed OVA provides a stable, high resolution, high sensitivity and low cost approach for characterizing optical devices with arbitrary response, especially for optical devices with large loss or bandpass response.

18 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LWLihan Wang
Lihan Wang
HYHuashan Yang
Huashan Yang
XWXiangchuan Wang
Xiangchuan Wang
XTXiaohu Tang
Xiaohu Tang
JWJingxian Wang
Jingxian Wang
SPShilong Pan
Shilong Pan
Measurement of the frequency response of sensors and devices with high-frequency resolution and sensitivity is of great importance for high-sensitive trace gas detection, high-quality photonic circuit fabrication, etc. Optical vector analysis (OVA) based on microwave photonics offers outstanding frequency resolution. However, the sensitivity of the incoherent detection system is usually limited. This paper proposes a self-calibrated coherent OVA system that leverages microwave photonic technology. The laser phase noise, which is the leading challenge in coherent detection, is compensated through a self-calibration process. Employing precise microwave sweeping paired with a highly stable laser, the proposed system achieves a theoretical frequency resolution at the level of Hertz. In the experiments, we demonstrate a sensitivity improvement of at least 35 dB over the incoherent system. In addition, the proposed OVA system offers superior frequency resolution and accuracy compared to commercial coherent OVA products.

9 November 2022 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
KSKunlin Shao
Kunlin Shao
YZYamei Zhang
Yamei Zhang
PGPenghui Gao
Penghui Gao
FYFeng Yang
Feng Yang
JZJianing Zhao
Jianing Zhao
SPShilong Pan
Shilong Pan
A microwave photonic phase detector (MPPD) for simultaneous synchronization of two independent microwave sources to a single mode-locked laser (MLL) with femtosecond-level residual timing jitters is firstly proposed and experimentally demonstrated. A Sagnac loop is built based on a dual-polarization dual-drive Mach-Zehnder modulator (DP-DMZM). Each path consisting a branch of the modulator forms an MPPD due to its feature of polarization multiplexing. Thus, two dielectric resonator oscillators (DROs) can be synchronized simultanesously. A proof-of-concept experiment is carried out. Two independent DROs with frequencies of 8.0320 and 8.3332 GHz are synchronized to an MLL. The phase noises of the synchronized 8.0320-GHz signal are -109.79 and -135.14 dBc/Hz at the 1-kHz and 10-kHz offset frequencies, respectively, and those of the 8.3332-GHz signal are -106.87 and -133.86 dBc/Hz. The residual timing jitters of the two synchronized signals (integrated from 100 Hz to 1 MHz) are around 2.12 fs and 5.93 fs, respectively. The impact of the amplitude and phase imbalances of the driven signals to the DP-DMZM on the performance of the MPPD is investigated.

24 July 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
XTXiaohu Tang
Xiaohu Tang
YCYuxiang Cai
Yuxiang Cai
PLPing Li
Ping Li
YZYamei Zhang
Yamei Zhang
SPShilong Pan
Shilong Pan
An adaptive microwave photonic multi-coset sampling (MCS) method is proposed to enable accurate and efficient sub-Nyquist acquisition of multiband radio frequency (RF) signals. The method integrates an activated Nyquist band sensor and a sampling pattern optimization module to dynamically optimize the sampling pattern based on prior spectral knowledge. The activated Nyquist band sensor can efficiently estimate the prior spectral support. A fine microwave frequency-sweeping technique is introduced to characterize both the sampling pattern and the measurement matrix, enabling precise calibration and control of the relative time delays in the sampling channels. A four-channel, 1-GSa/s microwave-photonic MCS system is implemented and experimentally validated. Multiband signals spanning four and eight distinct Nyquist bands across 0.01–40 GHz with a cumulative bandwidth of 2 GHz are adaptively sampled and successfully reconstructed. The proposed method demonstrates the ability to achieve the theoretical minimum sampling rate while maintaining a well-conditioned measurement matrix through optimized sampling pattern design. The experimental results further reveal that the system is robust to spectral aliasing and capable of resolving prealiasing components under limited sampling channels. This work represents, to the best of our knowledge, the first hardware demonstration of an adaptive microwave photonic multi-coset sampler with full-band sensing and sampling pattern control. Owing to its simple architecture, low sampling rate, and adaptability, the proposed system offers a promising solution for next-generation multiband RF front ends, particularly in applications such as multiband radar, wideband spectrum sensing, and cognitive radio.

15 October 2023
Verified
Conference Paper
Closed access
XTXiaohu Tang
Xiaohu Tang
YZYamei Zhang
Yamei Zhang
LWLihan Wang
Lihan Wang
KSKunlin Shao
Kunlin Shao
PLPing Li
Ping Li
SPShilong Pan
Shilong Pan
Multi-channel sampling time delay (STD) measurement and control is theoretically and experimentally demonstrated for time-wavelength interleaved photonic analog-to-digital converters. The intermediate frequency (IF) fixed frequency sweeping method is adopted to extract the phase shift of the down-converted IF signal for STD estimation. The experimental results demonstrate that the proposed method exhibits a measurement jitter of below 10 fs and a control accuracy of better than 25 fs within a short period.

20 December 2021 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
MCMeihui Cao
Meihui Cao
TQTing Qing
Ting Qing
LWLihan Wang
Lihan Wang
SLShupeng Li
Shupeng Li
YFYijie Fang
Yijie Fang
SPShilong Pan
Shilong Pan
A high-resolution optical vector analyzer (OVA) with wide measurement bandwidth based on microwave photonic frequency downconversion is proposed and experimentally demonstrated. In the proposed OVA, two pairs of frequency-swept dual-tone signals with different frequency intervals are used as the probe light. After passing through a device under test (DUT), the probe light is transmitted into a low-speed photodetector to perform frequency downconversion. Then, an intermediate frequency (IF) photocurrent with a fixed frequency is generated, which carries the DUT response. Hence, a low-speed electrical phase-magnitude detector (EPMD) can be employed to extract the magnitude and group delay responses of the DUT. Compared with the OVAs using the high-speed PD and ultrawide EPMD, the proposed approach is low-cost and has a high signal-to-noise ratio. In an experiment, the probe light is generated by the 2nd-order nonlinearity of the electro-optic modulator. Therefore, compared with conventional OVAs based on optical single-sideband (OSSB) or optical double-sideband (ODSB) modulation, the proposed OVA can achieve wide measurement bandwidth, which is four times (or two times) of that of the OSSB-based OVA (or the ODSB-based OVA). A frequency resolution of 6 MHz and a measurement bandwidth of 120 GHz are achieved.