Michaela Taylor-Williams

Michaela Taylor-Williams

Auto-generated profile, based on publicly available information

Michaela Taylor-Williams

University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MTMichaela Taylor-Williams
Michaela Taylor-Williams
GSGraham Spicer
Graham Spicer
GBGemma Bale
Gemma Bale
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Optical-imaging biomarkers are defined characteristics measured with an optical imaging modality to indicate normal biological or pathological processes. Optical-imaging biomarkers can help researchers better understand disease development and give clinicians the ability to diagnose and treat diseases in patients.1,2

12 December 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MTMichaela Taylor-Williams
Michaela Taylor-Williams
SMStephen Mead
Stephen Mead
TSTravis W. Sawyer
Travis W. Sawyer
LHLina Hacker
Lina Hacker
CWCalum Williams
Calum Williams
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Nailfold capillaroscopy is a noninvasive imaging modality used to evaluate nailfold capillary morphology and pathological changes of the finger.1 Capillaroscopy aids the clinical diagnosis and monitoring of rheumatological diseases, such as systemic sclerosis (SSc), also known as scleroderma.2 In particular, capillaroscopy forms part of the classification criteria used to diagnosis SSc.3 Video capillaroscopy, which is the gold standard in nailfold capillaroscopy, combines an optical microscope and digital camera to magnify the capillaries so that clinicians can accurately measure their morphology to assess abnormality (e.g., enlarged capillaries and decreased density),4 – 6 yet it fails to reveal the functional changes associated with capillary deformations.1,7 Microvascular deformation observed at the nailfold in SSc is hypothesized to arise due to hypoxia, but this has proven difficult to measure. Low oxygen is theorized to be a key element of the disease process; superficial skin changes are thought to mirror underlying changes occurring in internal organs.8 Understanding how blood oxygen saturation is related to microvascular deformation, and the role it plays in the development and progression of connective tissue disorders could improve disease diagnosis, monitoring, and treatment.9,10

1 March 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MTMichaela Taylor-Williams
Michaela Taylor-Williams
RTRan Tao
Ran Tao
TSTravis W. Sawyer
Travis W. Sawyer
DWDale J. Waterhouse
Dale J. Waterhouse
JYJonghee Yoon
Jonghee Yoon
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
SignificanceColor differences between healthy and diseased tissue in the gastrointestinal (GI) tract are detected visually by clinicians during white light endoscopy; however, the earliest signs of cancer are often just a slightly different shade of pink compared to healthy tissue making it hard to detect. Improving contrast in endoscopy is important for early detection of disease in the GI tract during routine screening and surveillance.AimWe aim to target alternative colors for imaging to improve contrast using custom multispectral filter arrays (MSFAs) that could be deployed in an endoscopic “chip-on-tip” configuration.ApproachUsing an open-source toolbox, Opti-MSFA, we examined the optimal design of MSFAs for early cancer detection in the GI tract. The toolbox was first extended to use additional classification models (k-nearest neighbor, support vector machine, and spectral angle mapper). Using input spectral data from published clinical trials examining the esophagus and colon, we optimized the design of MSFAs with three to nine different bands.ResultsWe examined the variation of the spectral and spatial classification accuracies as a function of the number of bands. The MSFA configurations tested showed good classification accuracies when compared to the full hyperspectral data available from the clinical spectra used in these studies.ConclusionThe ability to retain good classification accuracies with a reduced number of spectral bands could enable the future deployment of multispectral imaging in an endoscopic chip-on-tip configuration using simplified MSFA hardware. Further studies using an expanded clinical dataset are needed to confirm these findings.

12 August 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MTMichaela Taylor-Williams
Michaela Taylor-Williams
IKIrsa Khalil
Irsa Khalil
JMJoanne Manning
Joanne Manning
GDGraham Dinsdale
Graham Dinsdale
MBMichael Berks
Michael Berks
AMAndrea Murray
Andrea Murray
Background: Nailfold capillaroscopy enables visualisation of structural abnormalities in the microvasculature of patients with systemic sclerosis (SSc). The objective of this feasibility study was to determine whether multispectral imaging could provide functional assessment (differences in haemoglobin concentration or oxygenation) of capillaries to aid discrimination between healthy controls and patients with SSc. MSI of nailfold capillaries visualizes the smallest blood vessels and the impact of SSc on angiogenesis and their deformation, making it suitable for evaluating oxygenation-sensitive imaging techniques. Imaging of the nailfold capillaries offers tissue-specific oxygenation information, unlike pulse oximetry, which measures arterial blood oxygenation as a single-point measurement. Methods: The CAPoxy study was a single-centre, cross-sectional, feasibility study of nailfold capillary multispectral imaging, comparing a cohort of patients with SSc to controls. A nine-band multispectral camera was used to image 22 individuals (10 patients with SSc and 12 controls). Linear mixed-effects models and summary statistics were used to compare the different regions of the nailfold (capillaries, surrounding edges, and outside area) between SSc and controls. A machine learning model was used to compare the two groups. Results: Patients with SSc exhibited higher indicators of haemoglobin concentration in the capillary and adjacent regions compared to controls, which were significant in the regions surrounding the capillaries (p < 0.001). There were also spectral differences between the SSc and controls groups that could indicate differences in oxygenation of the capillaries and surrounding tissue. Additionally, an exploratory machine learning model distinguished SSc patients from healthy controls with 84% accuracy; these findings serve as a proof-of-concept for future studies. Conclusions: Data indicates that multispectral imaging differentiates between patients with SSc from controls based on differences in vascular function. Further work to develop a targeted spectral camera would further improve the contrast between patients with SSc and controls, enabling better imaging.

5 August 2025 in medRxiv
Verified
Preprint
Open access
PDF file
MTMichaela Taylor-Williams
Michaela Taylor-Williams
IKIrsa Khalil
Irsa Khalil
JMJoanne Manning
Joanne Manning
GDGraham Dinsdale
Graham Dinsdale
MBMichael Berks
Michael Berks
AMAndrea Murray
Andrea Murray
Background: Nailfold capillaroscopy enables visualisation of structural abnormalities in the microvasculature of patients with systemic sclerosis (SSc). The objective of this feasibility study was to determine whether multispectral imaging could provide functional assessment (differences in haemoglobin concentration or oxygenation) of capillaries to aid discrimination between healthy controls and patients with SSc. MSI of nailfold capillaries visualizes the smallest blood vessels and the impact of SSc on angiogenesis and their deformation, making it suitable for evaluating oxygenation-sensitive imaging techniques. Imaging of the nailfold capillaries offers tissue-specific oxygenation information, unlike pulse oximetry, which measures arterial blood oxygenation as a single-point measurement. Methods: The CAPoxy study was a single-centre, cross-sectional, feasibility study of nailfold capillary multispectral imaging, comparing a cohort of patients with SSc to controls. A nine-band multispectral camera was used to image 22 individuals (10 patients with SSc and 12 controls). Linear mixed-effects models and summary statistics were used to compare the different regions of the nailfold (capillaries, surrounding edges, and outside area) between SSc and controls. A machine learning model was used to compare the two groups. Results: Patients with SSc exhibited higher indicators of haemoglobin concentration in the capillary and adjacent regions compared to controls, which were significant in the regions surrounding the capillaries (p<0.001). There were also spectral differences between the SSc and controls groups that could indicate differences in oxygenation of the capillaries and surrounding tissue. Additionally, a machine learning model distinguished SSc patients from healthy controls with an accuracy of 84%, suggesting potential for multispectral imaging to classify SSc based on structural and functional microvascular changes. Conclusions: Data indicates that multispectral imaging differentiates between patients with SSc from controls based on differences in vascular function. Further work to develop a targeted spectral camera would further improve the contrast between patients with SSc and controls, enabling better imaging. Key messages: Multispectral imaging holds promise for providing functional oxygenation measurement in nailfold capillaroscopy. Significant oxygenation differences between individuals with systemic sclerosis and healthy controls can be detected with multispectral imaging in the tissue surrounding capillaries.