27 May 2022 in Nature Biomedical Engineering
26 March 2018 in British Journal of Cancer
Background Optoacoustic tomography (OT) of breast tumour oxygenation is a promising new technique, currently in clinical trials, which may help to determine disease stage and therapeutic response. However, the ability of OT to distinguish breast tumours displaying different vascular characteristics has yet to be established. The aim of the study is to prove OT as a sensitive technique for differentiating breast tumour models with manifestly different vasculatures. Methods Multispectral OT (MSOT) was performed in oestrogen-dependent (MCF-7) and oestrogen-independent (MDA-MB-231) orthotopic breast cancer xenografts. Total haemoglobin (THb) and oxygen saturation (SO2MSOT) were calculated. Pathological and biochemical evaluation of the tumour vascular phenotype was performed for validation. Results MCF-7 tumours show SO2MSOT similar to healthy tissue in both rim and core, despite significantly lower THb in the core. MDA-MB-231 tumours show markedly lower SO2MSOT with a significant rim–core disparity. Ex vivo analysis revealed that MCF-7 tumours contain fewer blood vessels (CD31+) that are more mature (CD31+/aSMA+) than MDA-MB-231. MCF-7 presented higher levels of stromal VEGF and iNOS, with increased NO serum levels. The vasculogenic process observed in MCF-7 was consistent with angiogenesis, while MDA-MB-231 appeared to rely more on vascular mimicry. Conclusions OT is sensitive to differences in the vascular phenotypes of our breast cancer models.
20 December 2023 in Journal of Biomedical Optics
Photoacoustic imaging (PAI) is an emerging molecular imaging modality that provides contrast based on the absorption of light by different molecules (chromophores) in tissue. These molecules may be endogenous, such as hemoglobin, melanin, lipids and water, or exogenous, covering a range of contrast agents.1,2 PAI has the potential to recover the concentration of each of these chromophores based on their unique optical absorption spectra, by acquiring data at multiple wavelengths and subjecting the reconstructed images to multispectral processing methods.3 For example, the recovery of relative concentrations of oxy- and deoxy-hemoglobin is commonly used to derive oxygenation maps from PAI with linear spectral unmixing.4 Obtaining accurate maps of chromophore concentrations, however, is limited by spatial variations in light fluence, which are significant at depth and are highly dependent on the surrounding distribution of optical absorbers and scatterers.3 This is often referred to as ‘spectral coloring’. Several factors can affect tissue optical properties, including age,5 low blood perfusion,6 or skin tone,7 which consequently affect the ability to extract quantitative information from PAI.
8 November 2023 in IEEE Transactions on Medical Imaging
Accurate measurement of optical absorption coefficients from photoacoustic imaging (PAI) data would enable direct mapping of molecular concentrations, providing vital clinical insight. The ill-posed nature of the problem of absorption coefficient recovery has prohibited PAI from achieving this goal in living systems due to the domain gap between simulation and experiment. To bridge this gap, we introduce a collection of experimentally well-characterised imaging phantoms and their digital twins. This first-of-a-kind phantom data set enables supervised training of a U-Net on experimental data for pixel-wise estimation of absorption coefficients. We show that training on simulated data results in artefacts and biases in the estimates, reinforcing the existence of a domain gap between simulation and experiment. Training on experimentally acquired data, however, yielded more accurate and robust estimates of optical absorption coefficients. We compare the results to fluence correction with a Monte Carlo model from reference optical properties of the materials, which yields a quantification error of approximately 20%. Application of the trained U-Nets to a blood flow phantom demonstrated spectral biases when training on simulated data, while application to a mouse model highlighted the ability of both learning-based approaches to recover the depth-dependent loss of signal intensity. We demonstrate that training on experimental phantoms can restore the correlation of signal amplitudes measured in depth. While the absolute quantification error remains high and further improvements are needed, our results highlight the promise of deep learning to advance quantitative PAI.
21 June 2021 in IEEE Transactions on Medical Imaging
Photoacoustic imaging (PAI) standardisation demands a stable, highly reproducible physical phantom to enable routine quality control and robust performance evaluation. To address this need, we have optimised a low-cost copolymer-in-oil tissue-mimickingmaterial formulation. The base material consists of mineral oil, copolymer and stabiliser with defined Chemical Abstract Service numbers. Speed of sound c ( f ) and acoustic attenuation coefficient $\alpha $ (f) were characterised over 2–10 MHz; optical absorption $\mu _{\mathrm {a}}$ ( $\lambda $ ) and reduced scattering $\mu _{\mathrm {s}}$ ’( $\lambda $ ) coefficients over 450–900 nm. Acoustic properties were optimised by modifying base component ratios and optical properties were adjusted using additives. The temporal, thermomechanical and photo-stabilitywere studied, alongwith intra-laboratory fabrication and field-testing. c(f) could be tuned up to (1516±0.6) $\text{m}\cdot \text{s}^{-1}$ and $\alpha $ (f) to (17.4±0.3)dB $\cdot $ cm $^{-1}$ at 5 MHz. The base material exhibited negligible $\mu _{\mathrm {a}}$ ( $\lambda $ ) and $\mu _{\mathrm {s}}$ ’( $\lambda $ ), which could be independently tuned by addition of Nigrosin or TiO 2 respectively. These properties were stable over almost a year and were minimally affected by recasting. The material showed high intra-laboratory reproducibility (coefficient of variation <4% for ${c}$ ( ${f}$ ), $\alpha $ ( ${f}$ ), optical transmittance and reflectance), and good photo- and mechanical-stability in the relevant working range (20–40°C). The optimised copolymer-in-oil material represents an excellent candidate for widespread application in PAI phantoms, with properties suitable for broader use in biophotonics and ultrasound imaging standardisation efforts.
4 September 2020 in Journal of Biomedical Optics
Photoacoustic imaging (PAI) is an emerging modality able to reveal high image contrast, arising from optical absorption in tissue at high spatial resolution, afforded by ultrasound detection. PAI is based on the photoacoustic principle,1 whereby pulsed light is absorbed by chromophores resulting in the generation of pressure waves that can be detected by ultrasound transducers at the tissue surface. Applying PAI at multiple wavelengths enables noninvasive, label-free detection of total hemoglobin concentration (THb) and oxygenation () based on the different optical absorption spectra of deoxygenated (HbR) and oxygenated hemoglobin ().2 The relative concentrations of these respective chromophores can then be calculated by spectroscopic inversion.3 PAI measures of THb () and () have been widely exploited to characterize tissues in the context of different pathologies, for example in breast cancer,4 – 6 melanomas,7,8 prostate cancer,9 – 11 nodal lesions of the head and neck,12 vascular diseases,13 – 15 and colitis.16 Particularly in cancer biology, THb and have proved to be of high value by allowing the detection of two cancer hallmarks: angiogenesis and hypoxia.17