Arturo Mejia-Barron

Arturo Mejia-Barron

Auto-generated profile, based on publicly available information

Arturo Mejia-Barron

Facultad de Ingeniería, Universidad Autónoma de Querétaro, Campus San Juan del Río, Río Moctezuma 249, Col. San Cayetano, 76807, México

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Measurement
Verified
Journal Article
Closed access
AMArturo Mejia-Barron
Arturo Mejia-Barron
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
DGDavid Granados-Lieberman
David Granados-Lieberman
JOJuan C. Olivares-Glavan
Juan C. Olivares-Glavan
RERafael Escarela-Perez
Rafael Escarela-Perez

15 January 2019 in Electronics
Verified
Journal Article
Open access
PDF file
AMArturo Mejia-Barron
Arturo Mejia-Barron
JSJ. Jesús De Santiago-Perez
J. Jesús De Santiago-Perez
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
The induction motor (IM) is one of the most important elements in industry. Although IMs are robust machines, they are susceptible to faults, where the stator winding short-circuit fault is one of the most common ones. In this work, the Shannon entropy (SE) index and a fuzzy logic (FL) system are proposed to diagnose short-circuit faults, considering both different severity levels and different load conditions. In the proposed methodology, a filtering stage based on brick-wall band-pass filters is firstly carried out. After this stage, the SE index is computed to quantify the fault severity and a FL system is applied to diagnose the IM condition in an automatic way. Unlike other works that propose some types of space transformations, the proposal is only based on a filtering stage and a time domain index, requiring low computational resources. The obtained results demonstrate the effectiveness of the proposal, i.e., the SE index quantifies the fault severity, regardless of the mechanical load, and the proposed FL system achieves a positive classification rate of 98%.

1 November 2017 in Electric Power Systems Research
Verified
Journal Article
Closed access
AMArturo Mejia-Barron
Arturo Mejia-Barron
MVMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
DGDavid Granados-Lieberman
David Granados-Lieberman
JOJuan C. Olivares-Glavan
Juan C. Olivares-Glavan
RERafael Escarela-Perez
Rafael Escarela-Perez

1 November 2015
Verified
Conference Paper
Closed access
JGJ. Luis Gonzalez-Cordoba
J. Luis Gonzalez-Cordoba
AMArturo Mejia-Barron
Arturo Mejia-Barron
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
Due to the negative impact on the equipment, monitoring of electrical disturbances has become a topic of interest for many researches around the world. In this work, a methodology for automatic classification of power quality disturbances (PQD) is proposed. It consists of three stages: first, the empirical mode decomposition for signal processing is applied; second, the entropy and energy are computed as features for pattern recognition and, finally, a neural network performs the automatic classification. The overall methodology is developed using Matlab software. Synthetic signals are used to train and validate de proposal. On the other hand, real measurements using a field programmable gate array (FPGA)-based data acquisition system (DAS) are carried out to test and show its effectiveness under real operating conditions. The obtained results show high accuracy and low computational burden.

29 January 2019 in Electronics
Verified
Journal Article
Open access
PDF file
AMArturo Mejia-Barron
Arturo Mejia-Barron
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
JHJOSE ROBERTO RAZO HERNANDEZ
JOSE ROBERTO RAZO HERNANDEZ
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
Phasor measurement units (PMUs) have become powerful monitoring tools for many applications in smart grids. In order to address the different issues related to harmonics in power systems, the fundamental phasor estimator in a PMU has been extended to the harmonic phasor estimator by several researchers around the world. Yet, the development of harmonic phasor estimators is a challenge because they have to consider time-varying frequencies since the frequency deviation in the harmonic components is proportional to the harmonic order in a dynamic way. In this work, a new algorithm for harmonic phasor estimation using an instantaneous single-sideband (SSB) modulation is presented. Unlike other SSB-based approaches, its implementation in this work is based on concepts of instantaneous phase and instantaneous frequency. In general, the proposed algorithm is divided into two stages. Firstly, the estimation of the fundamental phasor is carried out by means of a complex finite impulse response (FIR) filter which provides the analytic signal used to compute the instantaneous magnitude, phase, and frequency. Secondly, a complex FIR filter bank is proposed for the estimation of the harmonic components, where the instantaneous SSB modulation technique is applied in order to center the harmonic components into specific narrow bands for each complex filter when an off-nominal frequency occurs. The validation of the proposed algorithm is carried out by means of the current standards of phasor measurement units, i.e., Std. C37.118.1-2011 and C37.118.1a-2014, which involve steady-state, dynamic, and time performance tests.

1 November 2016
Verified
Conference Paper
Closed access
AMArturo Mejia-Barron
Arturo Mejia-Barron
MVMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
DGDavid Granados-Lieberman
David Granados-Lieberman
JAJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
CPCarlos Perez-Ramirez
Carlos Perez-Ramirez
DCDavid Camarena-Martinez
David Camarena-Martinez
Monitoring of voltage variations is a demanding issue for academic and industrial fields due mainly to their negative impact on equipment. In this work, a methodology based on adaptive filter using the least mean squares algorithm for tracking of voltage variations and a fuzzy logic system for automatic classification are proposed. The proposal consists of three stages: 1) denoising through a lowpass filter to remove non-fundamental frequency components, 2) envelope and type of voltage tracking, and 3) final classification according to the IEEE Std. 1159 using a rule-based decision process. In order to validate and test the proposal, a set of synthetic and real signals is used. The obtained results demonstrate the proposal effectiveness to detect and classify voltage variations, even when they are embedded in high level noise. Unlike other reported works, the proposed fuzzy logic system allows the tracking of the voltage variation such as sag, swell, or interruption over time, it means sample to sample.