Bingquan Wang

Bingquan Wang

Auto-generated profile, based on publicly available information

Bingquan Wang

Key Laboratory of Ultra-Precision Intelligent Instrumentation, Ministry of Industry and Information Technology, and the Center of Ultra-Precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin, China

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2023 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
BWBingquan Wang
Bingquan Wang
WSWeijia Shi
Weijia Shi
BZBo Zhao
Bo Zhao
XTXinqi Tian
Xinqi Tian
JTJiubin Tan
Jiubin Tan


19 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BWBingquan Wang
Bingquan Wang
WSWeijia Shi
Weijia Shi
BZBo Zhao
Bo Zhao
JTJiubin Tan
Jiubin Tan
The rapid and accurate measurement of the stress state of composite plates is crucial for enabling health monitoring and evaluation in their application fields. To address the need for high-efficiency and in-situ stress measurement of large component composite plates and the contradiction between the spatial resolution and accuracy, this paper proposes an air-coupled ultrasonic Lamb wave stress measurement method based on the step-difference acoustic time difference. With the guarantee of stress measurement accuracy, the spatial resolution is enhanced from propagation distance L 0 to step-difference distance Δ L , which can be adjusted automatically and accurately through mechanical devices. To verify the effectiveness of the proposed method, seven uniaxial tensile specimens are obtained along the different fiber directions of 0°, 15°, 30°, 45°, 60°, 75°, and 90°, respectively. Utilize stress coefficient calibration results K ΔL to realize the uniaxial stress measurement with a spatial resolution of 10 mm. The experimental results show that within the range of 0-100 MPa, the measurement errors are less than ±6.96 MPa, and the standard deviations of the repeatability measurement experiment do not exceed 10.84 MPa. The spatial resolution of stress measurement is enhanced from 150 mm to 10 mm, with an increase of 93.33%. The air-coupled ultrasonic Lamb wave in-situ stress measurement method based on the step-difference acoustic time difference can provide a feasible technique for high-efficiency and in-situ stress measurement of large component composite plates.

13 December 2025 in Measurement
Verified
Journal Article
Closed access
BWBingquan Wang
Bingquan Wang
YLYaxing Liu
Yaxing Liu
YSYimeng Shan
Yimeng Shan
YLYongbin Li
Yongbin Li