Share of current harmonics, which is taken from the power net, increases with the use of diode and thyristor rectifiers (so-called characteristic harmonics of current). One of the ways to minimize these harmonics is to use the active rectifier. The principle of operation of active rectifier is based on correct switching of transistors, which allows the two basic functions: a) to keep the first harmonic of current in phase with the first harmonic of voltage, power factor is approximately one, b) to achieve almost sinusoidal current, which is taken from the grid. Characteristic harmonics in the spectrum of the current, which is drawn from the grid by active rectifier, are negligible. There appear new harmonics in the spectrum of the current; these new harmonics are produced by switching frequency of transistors. These harmonics are little dependent on load. That can cause the fact that the proportional value of the examined harmonics is high, although the absolute value is actually low. This paper briefly describes the voltage-source active rectifier and its workings. The main part is devoted to results from simulations and measurements in the laboratory.
The most common cause of high voltage electric machine malfunction is an electrical failure of the insulation system due to extreme partial discharges activity. The paper discusses the methodology for the construction of a low-pass high voltage filter for partial discharge measurement. It focuses mainly on the shape optimization, using an analytical approach with subsequent verification using the finite element method. The experimental verification is given together with important conclusions.
Power electronic converters produce not only characteristic harmonics, but also both non-characteristic harmonics and interharmonics. This paper presents physical background of both non-characteristic harmonics and interharmonics. Generation causes are explored and discussed in detail. Extensive series of simulation of different power converter topologies are provided and compared with experimental results and existing standards. This research offers missing background for standards covering low-frequency EMC. (5 pages)
Adverse effects in voltage source inverter-fed drive systems are discussed. The paper focuses on the adverse influence of voltage source inverter on the fed motors. A very important part of the analysis is a model of the motor, especially determination of motor high frequency characteristics. Several representations (one-phase and three-phase) of the motor and the cable suitable for determination of motor transient overvoltage have been proposed. Factors contributing to the motor overvoltage are described. Influence of cable length, du/dt (rise time t/sub ON/) of voltage pulses and motor characteristics is investigated. The results are compared with data obtained from a number of experiments and simulations.
This paper presents the issue of current harmonics drawn from the grid by three-phase voltage-source active rectifiers when the switching frequency of the devices is random; it is not an integer multiple of the supply frequency (50 Hz). The first part compares the harmonic analysis calculations derived for the piecewise linearized simplified current waveform and the simulations in the random frequency case. The second part presents a comparison of the current harmonic analysis when the switching frequency is the integer multiple of the supply frequency and when it is not. The second part also shows a dependence of the current spectrums on the random switching frequencies. This paper verifies, that the same conclusions of the previous publications apply to both the switching frequency that is the integer multiple of the supply frequency and the random switching frequency.
The torque ripple has an adverse impact on the life of the machine and other drive components (especially bearings, gearboxes, couplings, etc.) and also produces an unpleasant acoustic noise. The reduction of the torque ripple can be solved in several ways - to select different configurations of SRM (to increase the number of phases or use the machine with higher number of steps), a suitable choice of commutation angles (so that they mutually overlap) or minimize the torque ripple by torque regulator or by direct torque control. This paper summarizes the practical results.