Ling Wang

Ling Wang

Auto-generated profile, based on publicly available information

Ling Wang

Key Laboratory of Radiometric Calibration and Validation for Environmental Satellites (LRCVES/CMA), National Satellite Meteorological Center, China Meteorological Administration (NSMC/CMA), Beijing, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2025 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Open access
Leiku YangLeiku Yang
Leiku Yang
XPXin Pei
Xin Pei
YSYidan Si
Yidan Si
XHXiuqing Hu
Xiuqing Hu
YFYizhe Fan
Yizhe Fan
XCXiaoqian Cheng
Xiaoqian Cheng
The Fengyun-3F (FY-3F) satellite, China's latest launched polar-orbiting meteorological satellite with morning overpass, carries the advanced Medium Resolution Spectral Imager-III (MERSI-III). Sharing similar characteristics with the Moderate Resolution Imaging Spectroradiometer (MODIS), MERSI-III/FY-3F has the potential to fill the observational gap in morning-orbit aerosol monitoring once Terra's mission concludes. This study adapts the aerosol retrieval algorithm originally developed for the MERSI-II sensor aboard the FY-3D satellite to the MERSI-III sensor. Algorithm improvements have been made to accommodate MERSI-III's characteristics, primarily focusing on optimizing the surface reflectance estimation model and updating the lookup tables. The improved algorithm has been applied to global MERSI-III observations for the entire year of 2024, and the first aerosol optical depth (AOD) retrieval results over ocean and land for this sensor have been produced and validated. The results show that MERSI-III AOD retrievals agree well with Aerosol Robotic Network (AERONET) data, with 69.8% and 71.0% of retrievals falling within expected error (EE) envelopes over ocean (± (0.03 + 10%)) and land (± (0.05 + 20%)), respectively. The accuracy of MERSI-III retrievals is comparable to that of Terra MODIS Dark Target (DT) products (EE: 65.3% over ocean, 73.4% over land). Comparative analysis of collocated MERSI-III and MODIS AOD datasets reveals consistent spatial patterns, although regional biases are observed in areas with high aerosol loading and near desert fringes. These results indicate that MERSI-III/FY-3F can provide reliable global aerosol observations and is expected to serve as an important candidate for the AOD data record from the morning-orbiting Terra/MODIS satellite.

29 May 2025 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
LWLing Wang
Ling Wang
CSChen Shuaishuai
Chen Shuaishuai
XHXiuqing Hu
Xiuqing Hu
XNXinghua Niu
Xinghua Niu
HXHanlie Xu
Hanlie Xu
NXNa Xu
Na Xu
The Medium Resolution Spectral Imager-III (MERSI-III), the third generation of the MERSI series, began observations from the Feng Yun-3F (FY-3F) in a sun-synchronous morning orbit on August 3, 2023. MERSI-III collects data from 25 spectral bands, including 19 reflective solar bands (RSBs) and 6 thermal emissive bands with wavelengths ranging from 0.4 to 2.15 μm and 3.7 to 12.5 μm, respectively. Compared with its predecessors, MERSI-III features an enhanced on-orbit calibration capability for RSBs thanks to the incorporation of a newly designed visible on-board calibrator (VOC). This VOC is a solar diffuser (SD)-based on-board calibration system consisting of an SD panel, a solar attenuation plate positioned in front of the SD panel, and an on-board SD degradation monitor. We provide an overview of the MERSI-III instrument, its VOC functions, and the corresponding on-orbit calibration methodologies. The performance of the on-orbit calibration is also assessed using a wide dynamic-integrated vicarious calibration (VC) technique, which combines multiple VC methods, including inter-comparison using invariant pixels, absolute calibration with pseudo-invariant calibration sites, and Rayleigh scattering calibration. Based on three months of validation results, the on-orbit calibration demonstrates strong performance in both absolute accuracy and radiometric stability. Among the 14 validated RSBs, 13 bands meet the basic calibration accuracy requirement of a calibration bias of less than 5%, while 7 bands meet the desired requirement of a calibration bias of less than 3%.

13 February 2025 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
HXHanlin Xiao
Hanlin Xiao
JAJingjing Ai
Jingjing Ai
JYJiaheng Yang
Jiaheng Yang
KCKang Chen
Kang Chen
XWXiaolin Wang
Xiaolin Wang
MWMingkun Wang
Mingkun Wang
In order to ensure the accuracy and reliability of the observational data from the remote sensor during its on-orbit operation, a sampling correction approach with the interpolation sliding window (ISWSCA) is proposed on the basis of the quadratic fitting and interpolation correction. The ISWSCA mitigates the effects of the inhomogeneous distribution of the reflective properties on the lunar surface, significantly enhancing the sampling correction accuracy of the lunar observation data by incorporating a subpixel correction term. Based on the lunar observation data from the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager (MERSI)-II collected between 2018 and 2023, the feasibility of the ISWSCA is verified, and the ISWSCA improves the sampling correction accuracy by 2.13% and 5.25% during low and high lunar phases in comparison to the scaling method of the lunar full-disk irradiance (LFDISM), together with the correction accuracy improved by 1.37% and 6% in low and high spatial resolutions. The ISWSCA gives the long time series of the normalized calibration coefficient, together with the calibration uncertainty of the effective data being analyzed, and the results show that the on-orbit stability of the FY-3D satellite is excellent in the visible (VIS) and near-infrared (NIF) bands, with the attenuation rate below 1.29% and the calibration uncertainty within 2.11%. This study has an important significance for the on-orbit radiation calibration of the spatial remote sensor.

6 March 2026 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
QYQiang Yu
Qiang Yu
Min MinMin Min
Min Min
DDDi Di
Di Di
YZYiming Zhao
Yiming Zhao
GLGuicai Li
Guicai Li
Peng ZhangPeng Zhang
Peng Zhang
Since its 2017 launch, the Moderate Resolution Imaging Spectroradiometer-II (MERSI-II) aboard the China Fengyun-3D (FY-3D) polar-orbiting satellite has delivered global observations of the atmosphere, oceans, and terrestrial vegetation, yet its reflective solar bands (RSBs) exhibit gradual on-orbit radiometric degradation and temporal fluctuations. We introduce a new Spectral-Fidelity-Preserving (SFP) cross-calibration framework that uses AQUA/MODIS (Moderate Resolution Imaging Spectroradiometer) as the reference. Unlike conventional approaches that homogenize spectral responses, the SFP model explicitly retains MERSI-II’s intrinsic spectral observation characteristics while correcting radiometric bias. When applied to FY-3D/MERSI-II observations (Jan 2018–Mar 2025), the seven recalibrated RSBs achieve a mean relative bias near 1% and a 2–3% improvement relative to the operational calibration coefficients, remaining stable throughout the 7-year record. Mann–Kendall tests identify distinct degradation breakpoints, with B05 (1.38 μm) and B06 (1.64 μm) changing earlier around October 2021 and other bands fluctuating after May 2024. We also produce daily calibration coefficients, substantially improving upon current monthly or semiannual updates. The related algorithm and daily calibration coefficients are publicly released on GitHub to support community uptake and operational use.