7 August 2020 in IEEE Transactions on Industrial Electronics
This paper presents a novel estimation method of the external force in linear series elastic actuators (SEAs). Conventionally, such force is estimated through the deflection of an elastic element, placed between motor and end-effector in SEAs (measured using two encoders). However, in some applications (e.g. wearable devices), it is difficult to mount a load-side encoder, due to cost or manufacturing issue. Moreover, methods based on encoders have limitations in terms of bandwidth, and, in turn, in estimating fast-varying impact forces. Additionally, SEAs may have a non-negligible end-effector mass, therefore gravity (or accelerations of the actuator support) may add a contribution to the external force, not accounted by deflection-based estimation methods. To address these issues, we propose a method based on the Kalman Filter in combination with the use of two MEMS accelerometers, mounted on the load-side and on the support of the SEA, for external force estimation and gravity (or support acceleration) compensation, respectively. We tested the proposed method even in a reduced version, with a single load-side accelerometer. Finally, it is shown that using the acceleration signal also improves the robustness against spring stiffness variations, compared to conventional methods. The experimental results show the effectiveness of the proposed methods.
12 January 2023 in Scientific Reports
Real haptics is a technology that reproduces the sense of force and touch by transmitting contact information with real objects by converting human movements and the feel of the objects into data. In recent years, real haptics technology has been installed in several surgical devices. A custom-made surgical drill was used to drill into the posterior lamina to verify the time required for penetration detection and the distance the drill advanced after penetration. A surgeon operated with the drill and the same aspects were measured and verified. All experiments were performed on female miniature pigs at 9 months of age with a mean body weight of 23.6 kg (range 9–10 months and 22.5–25.8 kg, n = 12). There were statistically significant differences in the average reaction time and the distance travelled after penetration between a handheld drill and the drill with the penetration detection function (p < 0.001). The reaction time to detect penetration and the distance after penetration were both significantly improved when compared with those of the handheld surgical drill without the penetration detection function, with mean differences of 0.049 ± 0.019 s [95% CI 0.012, 0.086 s] and 2.511 ± 0.537 mm [95% CI 1.505, 3.516 mm]. In this study, we successfully conducted a performance evaluation test of a custom-made haptic interface surgical drill. A prototype high-speed drill with a haptic interface accurately detected the penetration of the porcine posterior lamina.
6 May 2022 in IEEE/ASME Transactions on Mechatronics
This article proposes a radial-gap two-degree-of-freedom motor based on a magnetic screw structure. The proposed motor is composed of stator parts, rotor parts, and a mover part, and can generate torque and thrust force simultaneously and independently. Additionally, the motor can generate a large thrust force with the magnetic screw structure. In the proposed motor, the rotor parts and mover part, which act as the nut and screw of ball screws, are coupled with each other by means of magnetic force. Therefore, there is no friction between the rotor parts and mover part. The proposed motor can not only contribute to the minimization of multidegree-of-freedom systems, such as industrial robots but also improve the energy efficiency of robots. This article examines the effectiveness of the proposed motor through analysis and experimental results.
1 March 2019 in IEEJ Journal of Industry Applications
The in-circuit test is performed by pushing a needle-type probe into the printed circuit board (PCB) and measuring the conductivity between the electronic components. To reduce the testing time and improve the test reliability, a swift and stable motion of the probe is required, especially when the probe touches the surface of the PCB. Instead of the conventional method involving the use of a force sensor, this study investigates the application of a micro electronical mechanical systems accelerometer to realize the quick contacting motion. The detection of the contact instant is evaluated by the jerk signal from this device. Subsequently, a negative force is added to the probe and the proposed force control based on acceleration aided Kalman filter and reaction force observer is applied. The experimental verification indicates that the settling time is reduced to approximately 10ms and this corresponds to nearly 1% of the comparison data based on the existing technique.