Tomoyuki Shimono

Tomoyuki Shimono

Auto-generated profile, based on publicly available information

Tomoyuki Shimono

Kanagawa Institute of Industrial Science and Technology, Kawasaki, Kanagawa, Japan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
YMYukihito Moritoki
Yukihito Moritoki
TFTaichi Taichi Furukawa
Taichi Taichi Furukawa
JSJinyi Sun
Jinyi Sun
MYMinoru Yokoyama
Minoru Yokoyama
TSTomoyuki Shimono
Tomoyuki Shimono
SMShoji Maruo
Shoji Maruo
The development of handling technology for microscopic biological samples such as cells and spheroids has been required for the advancement of regenerative medicine and tissue engineering. In this study, we developed micro-tweezers with a compliant mechanism to manipulate organoids. The proposed method combines high-resolution microstereolithography that uses a blue laser and topology optimization for shape optimization of micro-tweezers. An actuation system was constructed using a linear motor stage with a force control system to operate the micro-tweezers. The deformation of the topology-optimized micro-tweezers was examined analytically and experimentally. The results verified that the displacement of the tweezer tip was proportional to the applied load; furthermore, the displacement was sufficient to grasp biological samples with an approximate diameter of several hundred micrometers. We experimentally demonstrated the manipulation of an organoid with a diameter of approximately 360 µm using the proposed micro-tweezers. Thus, combining microstereolithography and topology optimization to fabricate micro-tweezers can be potentially used in modifying tools capable of handling various biological samples.

7 August 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MYMinoru Yokoyama
Minoru Yokoyama
RPRazvan Andrei Budau Petrea
Razvan Andrei Budau Petrea
RORoberto Oboe
Roberto Oboe
TSTomoyuki Shimono
Tomoyuki Shimono
This paper presents a novel estimation method of the external force in linear series elastic actuators (SEAs). Conventionally, such force is estimated through the deflection of an elastic element, placed between motor and end-effector in SEAs (measured using two encoders). However, in some applications (e.g. wearable devices), it is difficult to mount a load-side encoder, due to cost or manufacturing issue. Moreover, methods based on encoders have limitations in terms of bandwidth, and, in turn, in estimating fast-varying impact forces. Additionally, SEAs may have a non-negligible end-effector mass, therefore gravity (or accelerations of the actuator support) may add a contribution to the external force, not accounted by deflection-based estimation methods. To address these issues, we propose a method based on the Kalman Filter in combination with the use of two MEMS accelerometers, mounted on the load-side and on the support of the SEA, for external force estimation and gravity (or support acceleration) compensation, respectively. We tested the proposed method even in a reduced version, with a single load-side accelerometer. Finally, it is shown that using the acceleration signal also improves the robustness against spring stiffness variations, compared to conventional methods. The experimental results show the effectiveness of the proposed methods.

12 January 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KYKento Yamanouchi
Kento Yamanouchi
STShunya Takano
Shunya Takano
YMYuichiro Mima
Yuichiro Mima
TMTakuya Matsunaga
Takuya Matsunaga
KOKouhei Ohnishi
Kouhei Ohnishi
MYMitsuru Yagi
Mitsuru Yagi
Real haptics is a technology that reproduces the sense of force and touch by transmitting contact information with real objects by converting human movements and the feel of the objects into data. In recent years, real haptics technology has been installed in several surgical devices. A custom-made surgical drill was used to drill into the posterior lamina to verify the time required for penetration detection and the distance the drill advanced after penetration. A surgeon operated with the drill and the same aspects were measured and verified. All experiments were performed on female miniature pigs at 9 months of age with a mean body weight of 23.6 kg (range 9–10 months and 22.5–25.8 kg, n = 12). There were statistically significant differences in the average reaction time and the distance travelled after penetration between a handheld drill and the drill with the penetration detection function (p < 0.001). The reaction time to detect penetration and the distance after penetration were both significantly improved when compared with those of the handheld surgical drill without the penetration detection function, with mean differences of 0.049 ± 0.019 s [95% CI 0.012, 0.086 s] and 2.511 ± 0.537 mm [95% CI 1.505, 3.516 mm]. In this study, we successfully conducted a performance evaluation test of a custom-made haptic interface surgical drill. A prototype high-speed drill with a haptic interface accurately detected the penetration of the porcine posterior lamina.

1 October 2014
Verified
Conference Paper
Closed access
STShodai Tanaka
Shodai Tanaka
TSTomoyuki Shimono
Tomoyuki Shimono
YFYasutaka Fujimoto
Yasutaka Fujimoto
This paper proposes a new cross-coupled two-degree-of-freedom (2DOF) direct drive motor which can independently realize rotary and linear motions. In this proposed motor, the mover part is a shaft with segment magnets formed in checkers. On the other hand, two sets of helical windings are cross-coupled in the stator part. The configuration can generate thrust force and torque independently. In this paper, the principle and the validity of the proposed motor are shown by electromagnetic field analysis and fabrication of the parts of an experimental motor is introduced.

6 May 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
YHYoshiyuki Hatta
Yoshiyuki Hatta
YFYasutaka Fujimoto
Yasutaka Fujimoto
TSTomoyuki Shimono
Tomoyuki Shimono
KIKazuaki Ito
Kazuaki Ito
This article proposes a radial-gap two-degree-of-freedom motor based on a magnetic screw structure. The proposed motor is composed of stator parts, rotor parts, and a mover part, and can generate torque and thrust force simultaneously and independently. Additionally, the motor can generate a large thrust force with the magnetic screw structure. In the proposed motor, the rotor parts and mover part, which act as the nut and screw of ball screws, are coupled with each other by means of magnetic force. Therefore, there is no friction between the rotor parts and mover part. The proposed motor can not only contribute to the minimization of multidegree-of-freedom systems, such as industrial robots but also improve the energy efficiency of robots. This article examines the effectiveness of the proposed motor through analysis and experimental results.

1 March 2019 in IEEJ Journal of Industry Applications
Verified
Journal Article
Open access
PDF file
SNSakahisa Nagai
Sakahisa Nagai
RORoberto Oboe
Roberto Oboe
TSTomoyuki Shimono
Tomoyuki Shimono
AKAtsuo Kawamura
Atsuo Kawamura
The in-circuit test is performed by pushing a needle-type probe into the printed circuit board (PCB) and measuring the conductivity between the electronic components. To reduce the testing time and improve the test reliability, a swift and stable motion of the probe is required, especially when the probe touches the surface of the PCB. Instead of the conventional method involving the use of a force sensor, this study investigates the application of a micro electronical mechanical systems accelerometer to realize the quick contacting motion. The detection of the contact instant is evaluated by the jerk signal from this device. Subsequently, a negative force is added to the probe and the proposed force control based on acceleration aided Kalman filter and reaction force observer is applied. The experimental verification indicates that the settling time is reduced to approximately 10ms and this corresponds to nearly 1% of the comparison data based on the existing technique.