Cone beam X-ray luminescence computed tomography (CB-XLCT) has been proposed as a promising hybrid imaging technique. Though it has the advantage of fast imaging, the inverse problem of CB-XLCT is seriously ill-conditioned, making the image quality quite poor, especially for imaging multi-targets. To achieve fast imaging of multi-targets, which is essential for in vivo applications, a truncated singular value decomposition (TSVD) based sparse view CB-XLCT reconstruction method is proposed in this study. With the weight matrix of the CB-XLCT system being converted to orthogonal by TSVD, the compressed sensing (CS) based L1-norm method could be applied for fast reconstruction from fewer projection views. Numerical simulations and phantom experiments demonstrate that by using the proposed method, two targets with different edge-to-edge distances (EEDs) could be resolved effectively. It indicates that the proposed method could improve the imaging quality of multi-targets significantly in terms of localization accuracy, target shape, image contrast, and spatial resolution, when compared with conventional methods.
As an emerging hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been proposed based on the development of X-ray excitable nanoparticles. Owing to the high degree of absorption and scattering of light through tissues, the CB-XLCT inverse problem is inherently ill-conditioned. Appropriate priors or regularizations are needed to facilitate reconstruction and to restrict the search space to a specific solution set. Typically, the goal of CB-XLCT reconstruction is to get the distributions of nanophosphors in the imaging object. Considering that the distributions of nanophosphors inside bodies preferentially accumulate in specific areas of interest, the reconstruction of XLCT images is usually sparse with some locally smoothed high-intensity regions. Therefore, a combination of the L1 and total variation regularization is designed to improve the imaging quality of CB-XLCT in this study. The L1 regularization is used for enforcing the sparsity of the reconstructed images and the total variation regularization is used for maintaining the local smoothness of the reconstructed image. The implementation of this method can be divided into two parts. First, the reconstruction image was reconstructed based on the fast iterative shrinkage-thresholding (FISTA) algorithm, then the reconstruction image was minimized by the gradient descent method. Numerical simulations and phantom experiments indicate that compared with the traditional ART, ADAPTIK and FISTA methods, the proposed method demonstrates its advantage in improving spatial resolution and reducing imaging time.
Cone-beam x-ray luminescence computed tomography (CB-XLCT) has been proposed as a promising imaging tool, which enables three-dimensional imaging of the distribution of nanophosphors (NPs) in small animals. However, the reconstruction performance is usually unsatisfactory in terms of spatial resolution due to the ill-posedness of the CB-XLCT inverse problem. To alleviate this problem and to achieve high spatial resolution, a reconstruction method consisting of inner and outer iterations based on a restarted strategy is proposed. In this method, the primal–dual Newton conjugate gradient method (pdNCG) is adopted in the inner iterations to get fast reconstruction, which is used for resetting the permission region and increasing the convergence speed of the outer iteration. To assess the performance of the method, both numerical simulation and physical phantom experiments were conducted with a CB-XLCT system. The results demonstrate that compared with conventional reconstruction methods, the proposed re-pdNCG method can accurately and efficiently resolve the adjacent NPs with the least relative error.
As an emerging hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been proposed based on the development of X-ray excitable nanoparticles. Fast three-dimensional (3-D) CB-XLCT imaging has attracted significant attention for the application of XLCT in fast dynamic imaging study. Currently, due to the short data collection time, single-view CB-XLCT imaging achieves fast resolving the three-dimensional (3-D) distribution of X-ray-excitable nanoparticles. However, owing to only one angle projection data is used in the reconstruction, the single-view CB-XLCT inverse problem is inherently ill-conditioned, which makes image reconstruction highly susceptible to the effects of noise and numerical errors. To solve the ill-posed inverse problem, using the sparseness of the X-ray-excitable nanoparticles distribution as the prior, a new reconstruction approach based on total variance is proposed in this study. To evaluate the performance of the proposed approach, a phantom experiment was performed based on a CB-XLCT imaging system. The experiments indicate that the reconstruction from single-view XCLT can provide satisfactory results based on the proposed approach. In conclusion, with the reconstruction approach based on total variance, we implement a fast XLCT reconstruction of high quality with only one angle projection data used, which would be helpful for fast dynamic imaging study. In future, we will focus on how to applying the proposed TV-based reconstruction method and CB-XLCT imaging system to image fast biological distributions of the X-ray excitable nanophosphors in vivo.