Luca Rovere

Luca Rovere

Auto-generated profile, based on publicly available information

Luca Rovere

Department of Electrical and Electronic Engineering, University of Nottingham, Nottingham, U.K.

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LRLuca Rovere
Luca Rovere
AFAndrea Formentini
Andrea Formentini
PZPericle Zanchetta
Pericle Zanchetta
This paper presents a novel Oversampling DeadBeat (OS-DB) current control approach for Permanent Magnet Synchronous Motors (PMSMs) drives capable of operating at a controller sampling frequency multiple of the power converter switching frequency. Model based controllers suffer form heavy computational demand and performance degradation due to parameters uncertainties. The proposed controller concurrently with FPGA implementation permits to achieve a constant switching frequency and an optimal current ripple along with a high current loop bandwidth and robust behaviour to parameters variation. A disturbance observer has been added to the proposed controller in order to compensate for the converter voltage distortions. The proposed control strategy is tested through both simulations and experiments.

25 March 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LRLuca Rovere
Luca Rovere
AFAndrea Formentini
Andrea Formentini
GCGiovanni Lo Calzo
Giovanni Lo Calzo
PZPericle Zanchetta
Pericle Zanchetta
TCTom Cox
Tom Cox
In this paper a dual-fed common dc-link topology Open-End Winding Permanent Magnet Synchronous Motor (OEW-PMSM) for aircraft high speed Starter-Generator application is considered. While on one hand the common dc bus configuration significantly simplifies and reduces the costs of the topology, on the other hand it allows the Zero-Sequence Current (ZSC) to flow freely in the system. High speed machines are characterized by low phase inductance which implies low Zero-Sequence Impedance (ZSI). A small time constant of the zero-sequence circuit produces a high frequency, high intensity ZSC ripple with the risk of harming the switching devices. This paper presents a novel hybrid Space Vector - Pulse Width Modulation (SVPWM) that allows to instantaneously eliminate the Zero-Sequence Voltage (ZSV) produced by the two Voltage Source Converters (VSCs) by square wave modulating one of the two VSCs. The non-sinusoidal machine back Electro Magnetic Force (back EMF) has been considered and an analysis of the converters' Dead Time (DT) effect on the ZSV has been carried out. The square wave modulated VSC uses IGBT devices while the other uses SiC technology. The proposed topology is tested through both simulations and experiments.

16 July 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RLRiccardo Leuzzi
Riccardo Leuzzi
VMVito Giuseppe Monopoli
Vito Giuseppe Monopoli
LRLuca Rovere
Luca Rovere
FCFrancesco Cupertino
Francesco Cupertino
PZPericle Zanchetta
Pericle Zanchetta
The use of fast wide-bandgap devices in high-speed electrical drives with steep pulsewidth modulation voltage waveforms is the main cause of increased stress on the electric machine insulation system and consequently, of reduced reliability of the whole system. This represents a major concern in safety-critical applications, such as in the aerospace and electric transportation fields. The novel contribution of this work is to assess the effects of electrical aging on complex insulation systems (i.e., a whole stator winding) by analyzing easily measurable macroscopic quantities. To this purpose, an electrical aging procedure is defined, and the effects produced on three tested motors are presented. Three different analysis methods are adopted with the aim of assessing the damage caused to an ac motor winding by such steep voltage waveforms and hence to evaluate the state of aging of the insulation system.

25 March 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LRLuca Rovere
Luca Rovere
AFAndrea Formentini
Andrea Formentini
GCGiovanni Lo Calzo
Giovanni Lo Calzo
PZPericle Zanchetta
Pericle Zanchetta
TCTom Cox
Tom Cox
In a common dc link dual-fed Open-End Winding Permanent Magnet Synchronous Motor (OEW-PMSM) topology it is well known how the additional flow of a Zero-Sequence Current (ZSC) is permitted. The low Zero-Sequence Impedance (ZSI) characteristic of high speed machines leads to high intensity and high frequency ripple of the ZSC. Therefore there is the necessity to eliminate the Zero-Sequence-Voltage (ZSV) produced by the two Voltage Source Converters (VSCs) that feed the machine. Furthermore the non-sinusoidal back Electro Magnetic Force (back EMF) causes the circulation of a third harmonic ZSC. An OEW-PMSM high speed starter-generator fed by a dual-inverter with single dc link is considered. Part I of this work proposes a modulation for the considered topology able to eliminate instantaneously the ZSV produced. In this paper a detailed analysis of the Dead Time (DT) effect on the ZSV has been carried out and a novel hysteresis control for the ZSC using the DT as a control action is presented. The DT produces a ZSV distortion on the zero axis that can be used to control the third harmonic ZSC flowing due to the non-sinusoidal machine back EMF.

2 March 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
AAAlbino Amerise
Albino Amerise
LRLuca Rovere
Luca Rovere
AFAndrea Formentini
Andrea Formentini
MMMichele Mengoni
Michele Mengoni
LZLuca Zarri
Luca Zarri
PZPericle Zanchetta
Pericle Zanchetta
A speed control scheme is presented for a 3-phase surface permanent magnet synchronous machine with an open-end stator winding fed by a three-phase inverter and a floating bridge inverter. The latter is used to compensate for the reactive power of the main inverter and to maximize the active power received by the motor, without exceeding the available stator current and DC-link voltage. To reduce the switching losses, the DC-link voltage of the floating inverter bridge varies depending on the operating condition of the motor and the controllability requirements of the system. The experimental results show that a significant improvement in the speed range at constant power is achievable, proportionally to the DC-link voltage of the floating bridge inverter.

9 October 2022
Verified
Conference Paper
Closed access
JRJacopo Riccio
Jacopo Riccio
LRLuca Rovere
Luca Rovere
SOShafiq Odhano
Shafiq Odhano
MNMauro Di Nardo
Mauro Di Nardo
PZPericle Zanchetta
Pericle Zanchetta
The aim of this manuscript is twofold. Firstly, it presents an analytical approach to study a synchronous reluctance motor drive configured in open-end winding. The intention is to identify the potential benefits of the floating capacitor configuration over the classical single inverter supply in terms of enlargement of the constant power speed range. A deep investigation was carried out on how varying the floating capacitor voltage level allows to modify the torque-versus-speed characteristics, enabling the drive to work at favorable operating points with high power factor. Secondly, the potential of the predictive control is exploited for such multi-variable system avoiding the non-trivial tuning difficulties necessary when standard controllers are considered, and allowing two converters to be controlled with a single cost function. Simulation results prove the desired operations with high power factor and extended constant torque region while keeping good dynamic performance.