Training the weighting factors of model predictive control in multi objective problems is a time consuming and sophisticated process. In this paper, Conventional Model Predictive Control (CMPC) has been developed as Supervised Learning Model Predictive Control (SLMPC) to cancel Common Mode Voltage (CMV) in three-phase NPC inverter while other control objectives are desirably tracked. SLMPC is accurately and quickly trained through Artificial Bee Colony (ABC) algorithm to optimize the controller weighting factors. Using the optimized weighting factors, transient response is minimized and CMV is surpassed. After training the weighting factors, SLMPC containing the optimized waiting factors is applied to the threephase NPC inverter without considering ABC algorithm in the control loop. By applying the optimized weighting factors to the cost function, SLMPC has been evaluated under several experimental and simulation tests to show that desired control objectives particularly CMV suppression have been attained. The proposed training process can be generalized and used for MPC cost functions with more control objectives to obtain the best possible performance.
11 November 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This article proposes hybrid selective harmonic mitigation (SHM)-pulsewidth modulation (PWM) that is characterized by both features harmonic mitigation and elimination aimed to reduce the common-mode voltage (CMV) and to mitigate the selected nontriplen harmonics in a three-phase neutral-point-clamped (NPC) inverter. As CMV harmonic modeling only shows triplens, the specified triplens are eliminated using the selective harmonic elimination (SHE) operation to control CMV pulsewidths and consequently to mitigate CMV magnitude that appears as its root-mean-square (rms) reduction. The determined nontriplen harmonics are also mitigated using the SHM approach by the same cost function. The proposed hybrid SHM-PWM empowered by both harmonic elimination and mitigation is implemented on a three-phase NPC inverter to confirm its performance on reducing CMV through experimental and theoretical analyses. It is shown that hybrid SHM is superior over pure SHE or SHM in dealing with multiobjective system, including CMV reduction and no ntriplen harmonics mitigation.
12 August 2019 in IEEE Transactions on Industrial Informatics
In this paper a Compatible Selective Harmonic Elimination (CSHE)-PWM is designed for three-leg four-wire (3L/4W) Neutral Point Clamped (NPC) inverter. The proposed CSHE-PWM is capable of eliminating both triplen and non-triplen harmonics from phase voltages and empowers 3L/4W NPC to handle both single/three-phase and linear/nonlinear loads. It has been mathematically proved that DC capacitors self-voltage balancing is achieved thanks to direct control of phase voltage waveform symmetry. Moreover, the cancellation of specified triplen and non-triplen orders has the advantage of having low capacitors voltage ripple. Therefore, the applied technique not only helps removing one leg of the inverter that reduces associate complex calculations and switching losses, but also directly controls phase voltage harmonic profile compared to SHE-PWM for four-leg four-wire (4L/4W) NPC. CSHE-PWM is practically tested on a NPC inverter prototype to validate the efficient harmonic elimination from the phase voltage waveforms along with capacitors voltages balancing under symmetrical/asymmetrical loads.