Raimund Leitner

Raimund Leitner

Auto-generated profile, based on publicly available information

Raimund Leitner

CTR Carinthian Tech Research AG (Austria)

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
JSJan Steinbrener
Jan Steinbrener
KPKonstantin Posch
Konstantin Posch
RLRaimund Leitner
Raimund Leitner

1 August 2003 in Real-Time Imaging
Verified
Journal Article
Closed access
RLR. Leitner
R. Leitner
HMH. Mairer
H. Mairer
AKA. Kercek
A. Kercek

1 February 2003 in Journal of Near Infrared Spectroscopy
Verified
Journal Article
Closed access
AKA. Kulcke
A. Kulcke
CGC. Gurschler
C. Gurschler
GSG. Spöck
G. Spöck
RLR. Leitner
R. Leitner
MKM. Kraft
M. Kraft
The lack of industrially-applicable, fast polymer classification systems is currently a major stumbling block in establishing both economically- and ecologically-useful waste recycling systems. With the advent of near infrared (NIR) spectral imaging for online classification, a method capable of distinguishing between different materials while simultaneously providing reliable size and shape information became available. In particular, polymer materials can be identified by their characteristic reflection spectra in the NIR without critical interferences from varying sample sizes and colours. A dedicated laboratory-scale prototype spectral imaging system has been developed and a number of classification algorithms have been evaluated for their applicability for polymer classification. Of the investigated algorithms, the Spectral Angle Mapper algorithm, supplemented by a threshold value and applied to the first derivatives of the normalised spectra, proved to be best suited for a rapid and reliable classification of polymers. Based on these achievements, an on-line system capable of classifying polymer parts delivered on a conveyor belt in real-time has been set up, which can be used, for example, as a sensor for fully-automated industrial polymer waste sorters.

1 January 2013 in Pattern Recognition Letters
Verified
Journal Article
Closed access
RLRaimund Leitner
Raimund Leitner
MBMartin De Biasio
Martin De Biasio
TAThomas Arnold
Thomas Arnold
CDCuong Viet Dinh
Cuong Viet Dinh
MLMarco Loog
Marco Loog
RDRobert P.W. Duin
Robert P.W. Duin

8 January 2018 in Current Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
VWVerena Wiedemair
Verena Wiedemair
MBM. De Biasio
M. De Biasio
RLR. Leitner
R. Leitner
DBD. Balthasar
D. Balthasar
Christian HuckChristian Huck
Christian Huck
Background: Meat fraud generated a huge outrage amongst customers in 2013 in Europe due to the horsemeat scandal. Portable and hand-held optical near-infrared (NIR, 4,00012,500 cm-1/800-2,500 nm) spectroscopy sensors are traded as promising fast, non-invasive and easy analytical tools that might be applicable at any independent place of inspection. In order to embrace the on-going trend towards instrumental miniaturization, it was the aim of the present feasibility study to evaluate the application of Design of Experiment for frequently applied portable micro-electro-mechanical system (MEMS) based spectrometer by comparing its performance to a bench-top Fourier-Transform polarization near-infrared (FT-NIR) instrument. Methods: 63 samples of different meat types (beef: 9, chicken: 10, mutton: 10, turkey: 10, pork: 10, horse meat: 14) were measured in order to classify the meat-type using a portable micro-electromechanical system (MEMS) based spectrometer and a bench-top Fourier-Transform polarization nearinfrared (FT-NIR) instrument, in order to compare the performance of both systems. In a second step different meat types were minced together in order to investigate the level of adulteration which can be detected using MEMS and FT-NIR. Design of Experiment (DoE) was applied to enhance results. Results: The accuracy of MEMS versus FT-NIR for identifying whole / minced pieces of chicken, pork, turkey, beef and mutton meat (63 samples) against horse meat appeared to be 75.0-100.0% (MEMS) vs. 62.5%-100.0% (FT-NIR) for whole pieces and 75.0-100.0% (MEMS and FT-NIR) for minced meat. When mincing different types of meat together, a maximum of 4 and 1 factors were required for establishing a PLS-R model using again the spectra recorded with MEMS and FT-NIR, respectively. The resulting quality parameters for the MEMS device were: R2=0.06-0.62, Standard Error of Cross Valdiation (SECV)= 17.33-32.91, Ratio of Performance to Deviation (RPD) =0,54-1,70 and for the FTNIR system: R2=0.85-0.94, SECV=7.52-13.83%, RPD=2.2-5.7 (FT-NIR). The limit of detection was found at 10% for the MEMS and at 1% for the FT-NIR device. Conclusion: Meat classification can be performed using the bench-top FT-NIR as well as the hand-held MEMS-NIR. Mincing the meat samples does not necessarily improve classification accuracy as information about the surface structure is lost. NIRS prediction models for adulterations were established for the bench-top system. Prediction models for the hand-held device are inconclusive and have to be improved by a larger sample set and/or further progress in miniaturization technique. Low level adulteration (<10%) may also be predictable with NIRS, but continuative research is necessary.

6 November 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MKMatic Krivec
Matic Krivec
GGGerald Mc Gunnigle
Gerald Mc Gunnigle
AAAnze Abram
Anze Abram
DMDieter Maier
Dieter Maier
RWRoland Waldner
Roland Waldner
RLRaimund Leitner
Raimund Leitner
The sensitivity of two commercial metal oxide (MOx) sensors to ethylene is tested at different relative humidities. One sensor (MiCS-5914) is based on tungsten oxide, the other (MQ-3) on tin oxide. Both sensors were found to be sensitive to ethylene concentrations down to 10 ppm. Both sensors have significant response times; however, the tungsten sensor is the faster one. Sensor models are developed that predict the concentration of ethylene given the sensor output and the relative humidity. The MQ-3 sensor model achieves an accuracy of ±9.2 ppm and the MiCS-5914 sensor model predicts concentration to ±7.0 ppm. Both sensors are more accurate for concentrations below 50 ppm, achieving ±6.7 ppm (MQ-3) and 5.7 ppm (MiCS-5914).