An unresolved issue in patients with diastolic dysfunction is that the estimation of myocardial stiffness cannot be decoupled from diastolic residual active tension (AT) because of the impaired ventricular relaxation during diastole. To address this problem, this paper presents a method for estimating diastolic mechanical parameters of the left ventricle (LV) from cine and tagged MRI measurements and LV cavity pressure recordings, separating the passive myocardial constitutive properties and diastolic residual AT. Dynamic C1-continuous meshes are automatically built from the anatomy and deformation captured from dynamic MRI sequences. Diastolic deformation is simulated using a mechanical model that combines passive and active material properties. The problem of non-uniqueness of constitutive parameter estimation using the well known Guccione law is characterized by reformulation of this law. Using this reformulated form, and by constraining the constitutive parameters to be constant across time points during diastole, we separate the effects of passive constitutive properties and the residual AT during diastolic relaxation. Finally, the method is applied to two clinical cases and one control, demonstrating that increased residual AT during diastole provides a potential novel index for delineating healthy and pathological cases.
Alternative forms of cardiac resynchronization therapy (CRT), including biventricular endocardial (BV-Endo) and multisite epicardial pacing (MSP), have been developed to improve response. It is unclear which form of stimulation is optimal. We aimed to compare the acute haemodynamic response (AHR) and electrophysiological effects of BV-Endo with MSP via two separate coronary sinus (CS) leads or a single-quadripolar CS lead. Fifteen patients with a previously implanted CRT system received a second temporary CS lead and left ventricular (LV) endocardial catheter. A pressure wire and non-contact mapping array were placed into the LV cavity to measure LVdP/dtmax and perform electroanatomical mapping. Conventional CRT, BV-Endo, and MSP were then performed (MSP-1 via two epicardial leads and MSP-2 via a single-quadripolar lead). The best overall AHR was found using BV-Endo pacing with a 19.6 ± 13.6% increase in AHR at the optimal endocardial site over baseline (P < 0.001). There was an increase in LVdP/dtmax with MSP-1 and MSP-2 compared with conventional CRT, but this was not statistically significant. Biventricular endocardial pacing from the optimal site was significantly superior to conventional CRT (P = 0.039). The AHR achieved when BV-Endo pacing was highly site specific. Within individuals, the best pacing modality varied and was affected by the underlying substrate. Left ventricular activation times did not predict the optimal haemodynamic configuration. Biventricular endocardial pacing and not MSP was superior to conventional CRT, but was highly site specific. Within individuals, however, different methods of stimulation are optimal and may need to be tailored to the underlying substrate.