Catheter ablation using RF energy is a common treatment for atrial arrhythmias. Although this treatment provides a potential cure, currently, there remains a high proportion of patients returning for repeat ablations. Electrophysiologists have little information to verify that a lesion has been created in the myocardium. Temporary electrical block can be created from edema, which will subside. MRI can visualize acute and chronic ablation lesions using delayed-enhancement techniques. However, the ablation patterns cannot be determined from 2-D images alone. Using the combination of T2-weighted and delayed-enhancement MRI, ablation lesions can be characterized in terms of necrosis and edema. A novel 3-D visualization technique is presented that projects the image intensity due the lesions onto a 3-D cardiac surface, allowing the complete, simultaneous visualization of the delayed-enhancement and T2 -weighted ablation patterns. Results show successful visualization of ablation patterns in 18 patients, and an application of this technique is presented in which electroanatomical mapping systems can be validated by overlaying the acquired ablation points onto the cardiac surfaces and assessing the correlation with the lesion maps.
5 March 2015 in Journal of Cardiovascular Electrophysiology
Lower Mortality and Eliminated PNS Associated with Quadripolar Leads: Introduction: Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long‐term improvement in patient outcome has yet to be demonstrated.Methods: A total of 721 consecutive patients with conventional CRTD criteria implanted with quadripolar (n = 357) or bipolar (n = 364) LV leads were enrolled into a registry at 3 UK centers. Lead performance and mortality was analyzed over a 5‐year period.Results: Patients receiving a quadripolar lead were of similar age and sex to those receiving a bipolar lead, although a lower proportion had ischemic heart disease (62.6% vs. 54.1%, P = 0.02). Both groups had similar rates of procedural success, although lead threshold, impedance, and procedural radiation dose were significantly lower in those receiving a quadripolar lead. PNS was more common in those with quadripolar leads (16.0% vs. 11.6%, P = 0.08), but was eliminated by switching pacing vector in all cases compared with 60% in the bipolar group (P < 0.001). Furthermore, LV lead displacement (1.7% vs. 4.6%, P = 0.03) and repositioning (2.0% vs. 5.2%, P = 0.03) occurred significantly less often in those with a quadripolar lead. All‐cause mortality was also significantly lower in the quadripolar compared to bipolar lead group in univariate and multivariate analysis (13.2% vs. 22.5%, P < 0.001).Conclusions: In a large, multicenter experience, the use of quadripolar LV leads for CRT was associated with elimination of PNS and lower overall mortality. This has important implications for LV pacing lead choice.
Alternative forms of cardiac resynchronization therapy (CRT), including biventricular endocardial (BV-Endo) and multisite epicardial pacing (MSP), have been developed to improve response. It is unclear which form of stimulation is optimal. We aimed to compare the acute haemodynamic response (AHR) and electrophysiological effects of BV-Endo with MSP via two separate coronary sinus (CS) leads or a single-quadripolar CS lead. Fifteen patients with a previously implanted CRT system received a second temporary CS lead and left ventricular (LV) endocardial catheter. A pressure wire and non-contact mapping array were placed into the LV cavity to measure LVdP/dtmax and perform electroanatomical mapping. Conventional CRT, BV-Endo, and MSP were then performed (MSP-1 via two epicardial leads and MSP-2 via a single-quadripolar lead). The best overall AHR was found using BV-Endo pacing with a 19.6 ± 13.6% increase in AHR at the optimal endocardial site over baseline (P < 0.001). There was an increase in LVdP/dtmax with MSP-1 and MSP-2 compared with conventional CRT, but this was not statistically significant. Biventricular endocardial pacing from the optimal site was significantly superior to conventional CRT (P = 0.039). The AHR achieved when BV-Endo pacing was highly site specific. Within individuals, the best pacing modality varied and was affected by the underlying substrate. Left ventricular activation times did not predict the optimal haemodynamic configuration. Biventricular endocardial pacing and not MSP was superior to conventional CRT, but was highly site specific. Within individuals, however, different methods of stimulation are optimal and may need to be tailored to the underlying substrate.
31 October 2011 in Pacing and Clinical Electrophysiology