1 November 2022 in Physics of Fluids
In this paper, based on a reasonable nucleus site density model and considering conjugate heat transfer, the coupled volume-of-fluid and level set method is adapted to study subcooled flow boiling in an inclined three-dimensional rectangular mini-channel (0-180{degree sign}) with a characteristic size of 1.0 mm at a low flow rate of 88.8 kg∙m-2∙s-1. The inclination angle is found to have a slight effect on the boiling of the flow. A bubbly flow appears when a heat flux of 300 kW/m2 is added. An unconventional impact force is exerted on larger bubbles because of the reduction in liquid flow area in the downstream region of the mini-channel. This causes large bubbles to slip along the heating wall, with slight differences in the flow pattern under different inclination angles. When the inclination angle is close to 0{degree sign}, the upstream small/medium bubbles leave the heating wall under gravitational effects, which is conducive to heat transfer. As the inclination angle approaches 90{degree sign}, gravity pushes the large bubbles downstream to leave the channel, favoring the rewetting of the dry patches below. These two positive effects begin to fail as the inclination angle approaches 180{degree sign}, leading to slightly worse overall heat exchange efficiency. However, the maximum differences in the average and local wall superheating of the mini-channel are only 8.4% and 20.1%, respectively, across the range of inclination angles because the flow pattern remains similar under the effect of the impact force.
1 March 2024 in Physics of Fluids
The interface tends to behave as a circular shape under the effect of surface tension in the two-dimensional two-phase fluid flow. In this study, based on the coupled volume-of-fluid and level set (VOSET) method, an accurate circle-based interface reconstruction (CIR) algorithm for structured meshes is proposed, which features a straightforward implementation procedure. A portion of the standard circle is employed to approximate the curve interface, without the need for complex classification, coordinate transformation, and equation transformation. The radius of this circle is computed simply by the curvature and signed distance at the mixed cell center, and the center of this circle is determined using a straightforward dichotomy method under the mass conservation constraints. Results indicate that the coupled VOSET and CIR (VOSET-CIR) method maintains superior computational accuracy in the signed distance, interface curvature, and dynamic interface reconstruction compared to the coupled VOSET and piecewise linear interface calculation (VOSET-PLIC) method, with accuracy improvements ranging from 34% to 1490% across different test cases. Furthermore, the VOSET-CIR method outperforms the efficient least squares volume-of-fluid interface reconstruction (ELVIRA) and PLIC algorithms in reconstructing random circles and surpasses the quadratic spline based interface reconstruction (QUASI) algorithm in reconstructing random squares. In terms of computational efficiency, except for the initial PLIC algorithm, the time costs of the VOSET-CIR method are substantially lower than those of the ELVIRA and QUASI algorithms, as well as the VOSET-PLIC method.
1 March 2024 in Physics of Fluids
Gravity plays a crucial role in influencing bubble behavior and heat transfer in flow boiling, and its impact can vary significantly in aerospace settings. Therefore, this study aims to numerically investigate flow boiling heat transfer in a rectangular mini-channel under hyper-gravity conditions, specifically at 12 times the normal gravity. To accomplish this, a coupled volume-of-fluid and level set method is employed, taking into account fluid-solid conjugated heat transfer as well as a nucleus site density model derived from experimental data. By reproducing the flow pattern and heat transfer characteristics under different heat flux and flow rate conditions, the study unveils the effects of hyper-gravity on flow boiling heat transfer. When the flow rate is lower under hyper-gravity conditions, a notable phenomenon occurs wherein numerous bubbles detach from the heating wall and coalesce into a vapor film at the top of the mini-channel due to increased buoyancy. In contrast, under normal gravity, bubbles merge and slide on the heating wall, leading to the formation of a dry patch below. Consequently, hyper-gravity results in a lower wall superheat, and the disparity in average wall superheat between normal and high gravities escalates as the added heat flux rises. Notably, in the hyper-gravity environment, the frequent detachment of bubbles in the middle and downstream sections of the mini-channel leads to an initial increase in wall superheating, followed by a plateau along the flow direction. As the flow rate increases, the inertial force intensifies. However, intriguingly, the discrepancy in flow boiling heat transfer between normal and high gravities does not exhibit a monotonic decrease with the increasing flow rate. This behavior can be attributed to the pressing of more bubbles onto the heating wall under normal gravity, resulting in the formation of dry patches at high velocities.
1 March 2024 in Physics of Fluids
For turbine blade internal cooling, the performance of turbulent flow and convective heat transfer in the cooling channel is numerically investigated via the computational fluid dynamics method, where the cooling channel adopts the combination of transverse rib arrangements and round-edged rib configurations or the combination of oblique rib arrangements and round-edged rib configurations. Under these two combination conditions, the simulation result shows that in the wide Reynolds number range of Re = 20 000–80 000, the heat transfer enhancement and the flow loss reduction, such as the larger normalized Nusselt number of Nu/Nu0 and smaller normalized friction factor of f/f0, are simultaneously realized by the oblique rather than transverse rib arrangement. In the oblique rib channel, the relationship between turbulent flow and convective heat transfer is for the first time revealed by the relationship between secondary vortices and turbulent kinetic energies. Based on the relation between secondary vortices and turbulent kinetic energies, the overall performance of turbulent flow and convective heat transfer for the oblique rib channel is first optimized by various normalized rib height, e/Dh, and rib spacing, p/e, and then evaluated by both overall performance factors of OPT1 and OPT2. Both OPT1 and OPT2 are larger at e/Dh = 0.062 and p/e = 15.00 in the wide range of e/Dh = 0.047–0.101 and p/e = 10.00–15.00. As a result of the comprehensive evaluation of OPT1 and OPT2, the combination of e/Dh = 0.062 and p/e = 15.00 is eventually employed by the oblique rib channel.
1 December 2024 in Physics of Fluids
Flow boiling demonstrates superior heat transfer performance and holds significant potential for thermal management applications. In this study, the great effects of aspect ratios of mini-channel on flow boiling heat transfer are reported by the numerical simulation method. Regarding the heat transfer coefficient (HTC), a boiling number threshold of 5.0 × 10−4 is obtained. Below this value, bubble detachment is not yet constrained by the channel, reducing the dry patches and providing better heat transfer at larger aspect ratios. Above this threshold, boiling becomes more intense, bubble size increases, making detachment easier in smaller aspect ratios, which show superior heat transfer performance. For the critical heat flux (CHF), at a flow rate of 0.1 m/s, the CHF for smaller aspect ratios is 77.78% higher than for larger aspect ratios. As the flow velocity increases, inertial forces begin to dominate bubble behavior, reducing the influence of channel size effects, and the differences in CHF gradually decrease. When the flow velocity exceeds 0.5 m/s, bubble behavior becomes similar, and the difference in CHF drops to less than 10%. This research highlights key parameters for optimizing mini-channel design, promoting the refinement and development of mini-channel structures.
1 February 2025 in Physics of Fluids
In an internal cooling channel, the overall thermal performance enhancement is studied under various hierarchical-truncated rib schemes via the computational fluid dynamics simulation. The simulation result shows that in a wide Reynolds number range, the low-pressure recirculation region behind ribs is significantly compressed by the linearly decreased rib height. Hence, with the linearly decreased rib height, the pressure drop penalty is significantly less under the hierarchical rib scheme than that under the non-hierarchical rib scheme, resulting in the overall thermal performance enhancement under the hierarchical rib scheme. In comparison with other hierarchical rib schemes, the distribution of smooth fluid flows, transverse vortices, and spanwise vortices is better under the hierarchical fractal-truncated rib scheme. Hence, under the hierarchical fractal-truncated rib scheme, there is better thermal performance. The overall thermal performance under the hierarchical fractal-truncated rib scheme is further enhanced by optimizing the distribution of smooth fluid flows, transverse vortices, and spanwise vortices. As a result of the optimized distribution, the best thermal performance is simultaneously realized by the optimized gap length and the optimized rib spacing in the wide Reynolds number range, which is composed of the significant heat transfer enhancement and the extreme flow loss reduction.