Raphael Tomi‐Tricot

Raphael Tomi‐Tricot

Auto-generated profile, based on publicly available information

Raphael Tomi‐Tricot

Research Department of Imaging Physics and Engineering School of Biomedical Engineering and Imaging Sciences, King's College London London UK

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Radiology
Verified
Journal Article
Closed access
JVJordina Aviles Verdera
Jordina Aviles Verdera
LSLisa Story
Lisa Story
MHMegan Hall
Megan Hall
TFTom Finck
Tom Finck
AEAlexia Egloff
Alexia Egloff
JHJana Hutter
Jana Hutter
Background The benefits of using low-field-strength fetal MRI to evaluate antenatal development include reduced image artifacts, increased comfort, larger bore size, and potentially reduced costs, but studies about fetal low-field-strength MRI are lacking. Purpose To evaluate the reliability and feasibility of low-field-strength fetal MRI to assess anatomic and functional measures in pregnant participants using a commercially available 0.55-T MRI scanner and a comprehensive 20-minute protocol. Materials and Methods This prospective study was performed at a large teaching hospital (St Thomas' Hospital; London, England) from May to November 2022 in healthy pregnant participants and participants with pregnancy-related abnormalities using a commercially available 0.55-T MRI scanner. A 20-minute protocol was acquired including anatomic T2-weighted fast-spin-echo, quantitative T2*, and diffusion sequences. Key measures like biparietal diameter, transcerebellar diameter, lung volume, and cervical length were evaluated by two radiologists and an MRI-experienced obstetrician. Functional organ-specific mean values were given. Comparison was performed with existing published values and higher-field MRI using linear regression, interobserver correlation, and Bland-Altman plots. Results A total of 79 fetal MRI examinations were performed (mean gestational age, 29.4 weeks ± 5.5 [SD] [age range, 17.6-39.3 weeks]; maternal age, 34.4 years ± 5.3 [age range, 18.4-45.5 years]) in 47 healthy pregnant participants (control participants) and in 32 participants with pregnancy-related abnormalities. The key anatomic two-dimensional measures for the 47 healthy participants agreed with large cross-sectional 1.5-T and 3-T control studies. The interobserver correlations for the biparietal diameter in the first 40 consecutive scans were 0.96 (95% CI: 0.7, 0.99; P = .002) for abnormalities and 0.93 (95% CI: 0.86, 0.97; P < .001) for control participants. Functional features, including placental and brain T2* and placental apparent diffusion coefficient values, strongly correlated with gestational age (mean placental T2* in the control participants: 5.2 msec of decay per week; R2 = 0.66; mean T2* at 30 weeks, 176.6 msec; P < .001). Conclusion The 20-minute low-field-strength fetal MRI examination protocol was capable of producing reliable structural and functional measures of the fetus and placenta in pregnancy. Clinical trial registration no. REC 21/LO/0742 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Gowland in this issue.

1 July 2019 in NeuroImage
Verified
Journal Article
Closed access
VGVincent Gras
Vincent Gras
BPBenedikt A. Poser
Benedikt A. Poser
XWXiaoping Wu
Xiaoping Wu
RTRaphaël Tomi-Tricot
Raphaël Tomi-Tricot
NBNicolas Boulant
Nicolas Boulant

30 June 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RTRaphaël Tomi‐Tricot
Raphaël Tomi‐Tricot
VGVincent Gras
Vincent Gras
BTBertrand Thirion
Bertrand Thirion
Franck MauconduitFranck Mauconduit
Franck Mauconduit
NBNicolas Boulant
Nicolas Boulant
AAAlexis Amadon
Alexis Amadon

10 March 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DLDavid Leitão
David Leitão
RTRaphael Tomi‐Tricot
Raphael Tomi‐Tricot
PBPip Bridgen
Pip Bridgen
TWTom Wilkinson
Tom Wilkinson
PLPatrick Alexander Liebig
Patrick Alexander Liebig
SMShaihan J. Malik
Shaihan J. Malik
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply.Theory and Methods: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root‐mean squared , , which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non‐selective sub‐pulses optimized over either a single 2D plane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8‐TX Nova head coil in five subjects were carried out to study the homogenization of and of the MT contrast by acquiring MT ratio maps.Results: Simulations and in vivo experiments showed up to six and two times more uniform compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub‐pulses were enough for the implementation and coil used.Conclusion: The proposed PUSH method obtains more uniform and higher MT contrast than CP mode within the same specific absorption rate (SAR) budget.

8 May 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
YBYannick Brackenier
Yannick Brackenier
LCLucilio Cordero‐Grande
Lucilio Cordero‐Grande
RTRaphael Tomi‐Tricot
Raphael Tomi‐Tricot
TWThomas Wilkinson
Thomas Wilkinson
PBPhilippa Bridgen
Philippa Bridgen
JHJoseph V. Hajnal
Joseph V. Hajnal
Purpose: To develop a fully data‐driven retrospective intrascan motion‐correction framework for volumetric brain MRI at ultrahigh field (7 Tesla) that includes modeling of pose‐dependent changes in polarizing magnetic (B0) fields.Theory and Methods: Tissue susceptibility induces spatially varying B0 distributions in the head, which change with pose. A physics‐inspired B0 model has been deployed to model the B0 variations in the head and was validated in vivo. This model is integrated into a forward parallel imaging model for imaging in the presence of motion. Our proposal minimizes the number of added parameters, enabling the developed framework to estimate dynamic B0 variations from appropriately acquired data without requiring navigators. The effect on data‐driven motion correction is validated in simulations and in vivo.Results: The applicability of the physics‐inspired B0 model was confirmed in vivo. Simulations show the need to include the pose‐dependent B0 fields in the reconstruction to improve motion‐correction performance and the feasibility of estimating B0 evolution from the acquired data. The proposed motion and B0 correction showed improved image quality for strongly corrupted data at 7 Tesla in simulations and in vivo.Conclusion: We have developed a motion‐correction framework that accounts for and estimates pose‐dependent B0 fields. The method improves current state‐of‐the‐art data‐driven motion‐correction techniques when B0 dependencies cannot be neglected. The use of a compact physics‐inspired B0 model together with leveraging the parallel imaging encoding redundancy and previously proposed optimized sampling patterns enables a purely data‐driven approach.

9 September 2025 in Neurology
Verified
Journal Article
Open access
KVKaty Vecchiato
Katy Vecchiato
CCChiara Casella
Chiara Casella
ADAyse Sila Dokumaci
Ayse Sila Dokumaci
ASAta Siddiqui
Ata Siddiqui
AEAlexia Egloff
Alexia Egloff
JOJonathan O'MUircheartaigh
Jonathan O'MUircheartaigh
Epileptogenic lesions in focal epilepsy can be subtle or remain undetected on conventional MRI. Ultra-high field (7T) MRI offers higher spatial resolution, contrast, and signal-to-noise ratio compared with conventional field strengths and has shown promise in adult presurgical evaluation. However, its utility in pediatric focal epilepsy, where malformations of cortical development are common, remains unclear. In this study, we directly compared 7T and 3T MRI in children with drug-resistant focal epilepsy, evaluating (1) scan tolerability, (2) image quality, and (3) lesion detection yield. In this prospective cohort study, patients were recruited from outpatient clinics at 3 large epilepsy centers in London. Eligible participants were aged 8-17 years and had no contraindications to MRI. Scanning was conducted in 2 separate sessions at 3T and 7T. Safety and tolerability were assessed using age-specific questionnaires and analyzed using the Mann-Whitney test for differences between age groups and the McNemar χ2 test for within-participant cross-field comparisons. Image quality was evaluated by a pediatric neuroradiologist and estimated quantitatively by comparing cortical thickness between field strengths. Lesion detection yield of 7T MRI was assessed by joint review with a multidisciplinary team. A total of 63 children were assessed: 41 patients (mean age 12.6 ± 2.4 years, 22 were male) and 22 healthy controls (8-17 years, mean age 11.7 ± 2.7 years, 15 were male). Both field strengths were well tolerated, and side effects were transient. These included higher dizziness-related discomfort at 7T (p = 0.02, Cohen h = 0.89), with side effects more frequently noted in younger children (scanner noise: p = 0.02, Cohen r = -0.36; metallic taste: p = 0.02, Cohen r = -0.37). Cortical thickness was significantly thinner at 7T for both right (t = 5.65, p < 0.001, Cohen d = -0.72) and left (t = 5.01, p < 0.001, Cohen d = -0.64) hemispheres, with thinner boundaries in temporo-parietal/sensory regions. Although 7T images had increased reported inhomogeneity and artifacts, new lesions were detected in 6 of 26 patients (23%), influencing surgical management in 4 of 26 (15%) (odds ratio 1.86). 7T MRI in children with epilepsy is well tolerated and associated with a 23% improvement in lesion detection, directly affecting clinical management and surgical outcomes. Although limited by a preselected cohort with extensive diagnostic workups, our findings underscore the transformative potential of 7T MRI in presurgical planning for pediatric epilepsy.