Thomas Wilkinson

Thomas Wilkinson

Auto-generated profile, based on publicly available information

Thomas Wilkinson

London Collaborative Ultra high field System (LoCUS), St Thomas' Hospital, United Kingdom

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SSSara Neves Silva
Sara Neves Silva
JVJordina Aviles Verdera
Jordina Aviles Verdera
RTRaphael Tomi‐Tricot
Raphael Tomi‐Tricot
RNRadhouene Neji
Radhouene Neji
AUAlena Uus
Alena Uus
JHJana Hutter
Jana Hutter
Purpose: To improve motion robustness of functional fetal MRI scans by developing an intrinsic real‐time motion correction method. MRI provides an ideal tool to characterize fetal brain development and growth. It is, however, a relatively slow imaging technique and therefore extremely susceptible to subject motion, particularly in functional MRI experiments acquiring multiple Echo‐Planar‐Imaging‐based repetitions, for example, diffusion MRI or blood‐oxygen‐level‐dependency MRI.Methods: A 3D UNet was trained on 125 fetal datasets to track the fetal brain position in each repetition of the scan in real time. This tracking, inserted into a Gadgetron pipeline on a clinical scanner, allows updating the position of the field of view in a modified echo‐planar imaging sequence. The method was evaluated in real‐time in controlled‐motion phantom experiments and ten fetal MR studies (17 + 4‐34 + 3 gestational weeks) at 3T. The localization network was additionally tested retrospectively on 29 low‐field (0.55T) datasets.Results: Our method achieved real‐time fetal head tracking and prospective correction of the acquisition geometry. Localization performance achieved Dice scores of 84.4% and 82.3%, respectively for both the unseen 1.5T/3T and 0.55T fetal data, with values higher for cephalic fetuses and increasing with gestational age.Conclusions: Our technique was able to follow the fetal brain even for fetuses under 18 weeks GA in real‐time at 3T and was successfully applied “offline” to new cohorts on 0.55T. Next, it will be deployed to other modalities such as fetal diffusion MRI and to cohorts of pregnant participants diagnosed with pregnancy complications, for example, pre‐eclampsia and congenital heart disease.

10 March 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DLDavid Leitão
David Leitão
RTRaphael Tomi‐Tricot
Raphael Tomi‐Tricot
PBPip Bridgen
Pip Bridgen
TWTom Wilkinson
Tom Wilkinson
PLPatrick Alexander Liebig
Patrick Alexander Liebig
SMShaihan J. Malik
Shaihan J. Malik
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply.Theory and Methods: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root‐mean squared , , which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non‐selective sub‐pulses optimized over either a single 2D plane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8‐TX Nova head coil in five subjects were carried out to study the homogenization of and of the MT contrast by acquiring MT ratio maps.Results: Simulations and in vivo experiments showed up to six and two times more uniform compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub‐pulses were enough for the implementation and coil used.Conclusion: The proposed PUSH method obtains more uniform and higher MT contrast than CP mode within the same specific absorption rate (SAR) budget.

8 May 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
YBYannick Brackenier
Yannick Brackenier
LCLucilio Cordero‐Grande
Lucilio Cordero‐Grande
RTRaphael Tomi‐Tricot
Raphael Tomi‐Tricot
TWThomas Wilkinson
Thomas Wilkinson
PBPhilippa Bridgen
Philippa Bridgen
JHJoseph V. Hajnal
Joseph V. Hajnal
Purpose: To develop a fully data‐driven retrospective intrascan motion‐correction framework for volumetric brain MRI at ultrahigh field (7 Tesla) that includes modeling of pose‐dependent changes in polarizing magnetic (B0) fields.Theory and Methods: Tissue susceptibility induces spatially varying B0 distributions in the head, which change with pose. A physics‐inspired B0 model has been deployed to model the B0 variations in the head and was validated in vivo. This model is integrated into a forward parallel imaging model for imaging in the presence of motion. Our proposal minimizes the number of added parameters, enabling the developed framework to estimate dynamic B0 variations from appropriately acquired data without requiring navigators. The effect on data‐driven motion correction is validated in simulations and in vivo.Results: The applicability of the physics‐inspired B0 model was confirmed in vivo. Simulations show the need to include the pose‐dependent B0 fields in the reconstruction to improve motion‐correction performance and the feasibility of estimating B0 evolution from the acquired data. The proposed motion and B0 correction showed improved image quality for strongly corrupted data at 7 Tesla in simulations and in vivo.Conclusion: We have developed a motion‐correction framework that accounts for and estimates pose‐dependent B0 fields. The method improves current state‐of‐the‐art data‐driven motion‐correction techniques when B0 dependencies cannot be neglected. The use of a compact physics‐inspired B0 model together with leveraging the parallel imaging encoding redundancy and previously proposed optimized sampling patterns enables a purely data‐driven approach.

9 September 2025 in Neurology
Verified
Journal Article
Open access
KVKaty Vecchiato
Katy Vecchiato
CCChiara Casella
Chiara Casella
ADAyse Sila Dokumaci
Ayse Sila Dokumaci
ASAta Siddiqui
Ata Siddiqui
AEAlexia Egloff
Alexia Egloff
JOJonathan O'MUircheartaigh
Jonathan O'MUircheartaigh
Epileptogenic lesions in focal epilepsy can be subtle or remain undetected on conventional MRI. Ultra-high field (7T) MRI offers higher spatial resolution, contrast, and signal-to-noise ratio compared with conventional field strengths and has shown promise in adult presurgical evaluation. However, its utility in pediatric focal epilepsy, where malformations of cortical development are common, remains unclear. In this study, we directly compared 7T and 3T MRI in children with drug-resistant focal epilepsy, evaluating (1) scan tolerability, (2) image quality, and (3) lesion detection yield. In this prospective cohort study, patients were recruited from outpatient clinics at 3 large epilepsy centers in London. Eligible participants were aged 8-17 years and had no contraindications to MRI. Scanning was conducted in 2 separate sessions at 3T and 7T. Safety and tolerability were assessed using age-specific questionnaires and analyzed using the Mann-Whitney test for differences between age groups and the McNemar χ2 test for within-participant cross-field comparisons. Image quality was evaluated by a pediatric neuroradiologist and estimated quantitatively by comparing cortical thickness between field strengths. Lesion detection yield of 7T MRI was assessed by joint review with a multidisciplinary team. A total of 63 children were assessed: 41 patients (mean age 12.6 ± 2.4 years, 22 were male) and 22 healthy controls (8-17 years, mean age 11.7 ± 2.7 years, 15 were male). Both field strengths were well tolerated, and side effects were transient. These included higher dizziness-related discomfort at 7T (p = 0.02, Cohen h = 0.89), with side effects more frequently noted in younger children (scanner noise: p = 0.02, Cohen r = -0.36; metallic taste: p = 0.02, Cohen r = -0.37). Cortical thickness was significantly thinner at 7T for both right (t = 5.65, p < 0.001, Cohen d = -0.72) and left (t = 5.01, p < 0.001, Cohen d = -0.64) hemispheres, with thinner boundaries in temporo-parietal/sensory regions. Although 7T images had increased reported inhomogeneity and artifacts, new lesions were detected in 6 of 26 patients (23%), influencing surgical management in 4 of 26 (15%) (odds ratio 1.86). 7T MRI in children with epilepsy is well tolerated and associated with a 23% improvement in lesion detection, directly affecting clinical management and surgical outcomes. Although limited by a preselected cohort with extensive diagnostic workups, our findings underscore the transformative potential of 7T MRI in presurgical planning for pediatric epilepsy.

9 November 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ADAyşe Sıla Dokumacı
Ayşe Sıla Dokumacı
FAFraser R. Aitken
Fraser R. Aitken
JSJan Sedlacik
Jan Sedlacik
PBPip Bridgen
Pip Bridgen
RTRaphael Tomi‐Tricot
Raphael Tomi‐Tricot
DCDavid W. Carmichael
David W. Carmichael
Purpose: The MP2RAGE sequence is typically optimized for either T1‐weighted uniform image (UNI) or gray matter–dominant fluid and white matter suppression (FLAWS) contrast images. Here, the purpose was to optimize an MP2RAGE protocol at 7 Tesla to provide UNI and FLAWS images simultaneously in a clinically applicable acquisition time at 85% of the optimal UNI contrast‐to‐noise ratio. Using TI1/TI2/TRMP2RAGE of 650/2280/4000 ms, 6/8 partial Fourier in the inner phase‐encoding direction, and GRAPPA factor = 4 in the other, images with 0.65 mm isotropic resolution were produced in <7.5 min. The contrast‐to‐noise ratio was around 20% smaller at TRMP2RAGE = 4000 ms compared to that at TRMP2RAGE = 5000 ms; however, the 20% shorter duration makes TRMP2RAGE = 4000 ms a good candidate for clinical applications example, pediatrics.Conclusion: FLAWS and UNI images could be obtained in a single scan with 0.65 mm isotropic resolution, providing a set of high‐contrast images and full brain coverage in a clinically applicable scan time. Images with excellent anatomical detail were demonstrated over a wide age range using the optimized parameter set.

28 March 2023 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PBPhilippa Bridgen
Philippa Bridgen
SMShaihan Malik
Shaihan Malik
TWThomas Wilkinson
Thomas Wilkinson
JCJohn Cronin
John Cronin
TBTahzeeb Bhagat
Tahzeeb Bhagat
BBBenjamin J. Blaise
Benjamin J. Blaise