Henry Chen

Henry Chen

Auto-generated profile, based on publicly available information

Henry Chen

Department of Imaging Physics The University of Texas MD Anderson Cancer Center Houston Texas USA

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JSJeremiah Sanders
Jeremiah Sanders
HCHenry Szu‐Meng Chen
Henry Szu‐Meng Chen
JJJason M. Johnson
Jason M. Johnson
DSDonald F. Schomer
Donald F. Schomer
JJJorge E. Jimenez
Jorge E. Jimenez
Ho-Ling LiuHo-Ling Liu
Ho-Ling Liu

2 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
HCHenry Szu‐Meng Chen
Henry Szu‐Meng Chen
VKVinodh A. Kumar
Vinodh A. Kumar
JJJason Johnson
Jason Johnson
MCMelissa M. Chen
Melissa M. Chen
KNKyle Noll
Kyle Noll
Ho-Ling LiuHo-Ling Liu
Ho-Ling Liu

19 July 1996
Verified
Conference Paper
Closed access
PDF file
HCHenry Chen
Henry Chen
SEStephen U. Egarievwe
Stephen U. Egarievwe
ZHZhirun Hu
Zhirun Hu
JTJianhua Tong
Jianhua Tong
DSD T Shi
D T Shi
LBLyle M Bartlett
Lyle M Bartlett
Radiation detectors have been fabricated from Cd1-xZnxTe crystals and their performance has been studied with respect their Cd1-xZnxTe surface preparation. Energy resolution, leakage current, resistivity, ohmicity as well as surface roughness of the detectors were measured and compared for various chemical treatments. Etching in lactic acid has been found to lead to better ohmic contract, a rougher surface and higher leakage current. Bromine is effective in removing the damaged layer and when added to 20 percent lactic acid in ethylene glycol leads to a lower leakage current and consequently a better energy resolution. The best detector performance was obtained with a two step treatment consisting of a standard etchant (5 percent Br in methanol) followed by 2 percent Br in'20 percent lactic acid in ethylene glycol'. The results clearly demonstrate the important of surface chemical treatments in the fabrication of Cd1-xZnxTe radiation detectors.

1 October 2011
Verified
Conference Paper
Closed access
MGMichelle L. Galloway
Michelle L. Galloway
MAMark Amman
Mark Amman
SASalah Awadalla
Salah Awadalla
GBGlenn Bindley
Glenn Bindley
SBSteven E. Boggs
Steven E. Boggs
AZAndreas Zoglauer
Andreas Zoglauer
The High Efficiency Multimode Imager (HEMI) is an instrument to detect, locate, and spectroscopically characterize radioactive sources with gamma-ray emissions at long-range standoff distances. HEMI consists of modular cubic-centimeter coplanar-grid CdZnTe detector elements configured in a two-plane array that allows for both Compton scattering and coded aperture imaging. Measurements and simulations have been performed using a variety of radioactive sources at different positions with respect to a prototype HEMI array in order to demonstrate the source identification and localization capabilities of the system. This paper will provide an overview of the HEMI instrument as well as present results from simulations and measurements using the completed detector array.

26 May 2022
Verified
Conference Paper
Open access
HCHenry Chen
Henry Chen
WSWenkang Song
Wenkang Song
Hongwei ZhuHongwei Zhu
Hongwei Zhu
STSheng-Tsung Tsao
Sheng-Tsung Tsao
JDJie Du
Jie Du
SPIE Digital Library Proceedings