26 September 2022 in Solid Earth Sciences
1 January 2023 in AIP Conference Proceedings
Over decades, urban roads in Jakarta have been suffering from flooding due to excessive surface runoff. A majority of existing urban road pavement installation in Jakarta has been utilizing the conventional pavement type. A typical conventional pavement is ineffective in reducing the surface runoff volume, particularly during high precipitation events. All stormwater has to flow onto the drainage with extreme discharge. As a consequence, the urban roads are full of puddles of various heights and lengths of time. To reflect on this issue, the authors conducted a review paper, to sum up, the extensive but dispersed literature on commonly permeable pavements. This study reviewed porous asphalt, pervious concrete, and interlocking concrete pavers. In addition, four crucial points are highlighted as consideration: (1) the structural capability, (2) permeability, (3) water quality and (4) economic risk. This research review concluded that permeable pavement is more effective in reducing flooding compared to conventional pavement. Among those three pavement types, porous asphalt pavement is the most possible to be implemented for urban roads in Jakarta, especially for light traffic. Since this pavement meets the Indonesian national standard requirements for structural capability and has less economic risk.
10 April 2023 in Jurnal Teknik Sipil
This study focuses on designing the steel structure construction toward earthquake load, which uses Istana Qur’an as a research object. Modeling and designing the steel structural building by using two different software, SAP2000, and Tekla Structure. In the making process, the authors made presumptions on workload according to Indonesian Design Standards such as minimum design loads, seismic load design, seismic load for steel structure design, and joints in steel structure. Not only from a structural strength view for human safety but also the construction time and material cost are also able to be estimated which is becoming faster and more affordable compared to implementing the conventional method. As a full analysis result, in this steel design, there are six different steel profiles were used for steel building construction. For instance, IWF 440.300.11.18 as the column, IWF 350.175.7.11 and IWF 250.125.6.9 as the beams, IWF 200.100.5,5.8 as the gable roof frame, UNP 150.75.9.12,5 as purlin and L 150.150.15 as collar tie.
1 January 2023 in AIP Conference Proceedings
Earthquakes are one of the disasters that often occur in Indonesia. This disaster causes severe vibrations in buildings, which impact structural failure so that a building can suffer damage or even destruction. Based on official data from BNPB, from 2000-2020, there were 282 earthquake cases in Indonesia, up to 71,174 fatalities. For example, a tectonic earthquake with a magnitude of 5.9 SR for 57 seconds struck D.I Yogyakarta and parts of Central Java in 2006, to be precise, at 05:55 WIB, claiming more than 6000 lives. A large number of casualties was caused by the community’s unpreparedness for the earthquake that occurred. The risk of earthquakes is greatest from night to morning when the majority of the population is resting. Therefore, it is necessary to innovate and educate the public about disaster mitigation in the form of technological innovation in early warning of earthquake disasters. This system is a piezoelectric sensor that is planted in the ground. This piezoelectric sensor works when a vibration occurs due to an earthquake. The sensor can work when the land perception occurs> 0.14 m / s2, which is included in the medium scale earthquake categorized as Meecally scale IV. In this study, historical data for the 2006 Yogyakarta earthquake which occurred at a depth of 12.5 km, precisely at the coordinates of 7,977o South Latitude and 110,318 East Longitude, with an epicenter position as far as 20 km and a hypocenter distance of 23.5 km with the ground acceleration method from Donovan (1973) and Estave (1970). The results obtained meecally IV scale with digital microcontroller (ADC)> 11.55 and sensor voltage value (V)> 0.056 so that it can activate the sensor and turn on the siren as an early warning.