Haipeng Li

Haipeng Li

Auto-generated profile, based on publicly available information

Haipeng Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2018 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
MEMatthew J. Easton
Matthew J. Easton
HLHaipeng Li
Haipeng Li
YLYuanrong Lu
Yuanrong Lu
JZJie Zhu
Jie Zhu
PPPierre-Daniel Pfister
Pierre-Daniel Pfister
Magnets to be used for the internal quadrupoles of an interdigital H-mode drift tube linear accelerator (IH-DTL) using KONUS beam dynamics should be both compact in size and high in focusing field gradient. Permanent magnets are an attractive solution, but then the ability to adjust the field strength is lost. We investigated two different solutions to this problem: the first using external adjustable electromagnets; the second using internal adjustable permanent magnets. The first method moves the variability out of the resonant cavity, using adjustable electromagnet quadrupole doublets before entry into the IH-DTL to compensate for the lack of internal variability. We carried out optimization simulations with custom code that ran many instances of the lorasr beam dynamics simulation software, using different values of field strength for the external doublets. By optimizing the magnet settings for different values of input current, we were able to compensate for the space-charge forces involved in accelerating a high-intensity continuous-wave (CW) deuteron beam. Second, we designed some novel adjustable permanent-magnet quadrupoles to be used inside the cavity, which combine the advantages of small cross-section and variable field gradient. This allows much more control over the beam, and even other ion species with differing charge-to-mass ratios can be accommodated within the same accelerator design. We developed two adjustable permanent-magnet designs: one with an electromagnetic component, and the other with two concentric moving rings of Halbach-array quadrupoles.

15 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLShuo Liu
Shuo Liu
YWYaxia Wei
Yaxia Wei
YLYuanrong Lu
Yuanrong Lu
ZWZhi Wang
Zhi Wang
MHMeiyun Han
Meiyun Han
PZPengfei ZHENG
Pengfei ZHENG
In order to figure out the migration and deposition of impurities on the first wall of HL-2A/2M tokamak, Peking University and Southwestern Institute of Physics are co-developing a deuteron RFQ as part of the in situ ion-beam diagnostic for the material. The RFQ, which operates at 162.5 MHz, is designed to accelerate a 10-mA deuteron beam from 40 keV up to 1.5 MeV. Key design considerations and the final design parameters are presented. The RFQ has been conditioned at a 1% duty factor for 80 h at RF cavity power of 55 kW. The specific shunt impedance of the cavity is 221 kΩ·m by measuring the bremsstrahlung spectrum. The intrinsic Q-value after the high-power tests measured by the Ring-Down method is 13,780. Beam commissioning has been taken place during the first half of 2021, and the beam measurements include beam current and energy of 2H+ ion. A 10 mA 2H+ beam was successfully accelerated through the RFQ.