1 December 2022 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Open access
PDF file
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
JBJulio Barbera
Julio Barbera
DGDavid Sanchez Gonzalo
David Sanchez Gonzalo
AMAlvaro Mondejar
Alvaro Mondejar
MFMarta Freire
Marta Freire
JBJose M. Benlloch
Jose M. Benlloch
In this article, we present the geometrical design and preliminary results of a high sensitivity organ-specific Positron Emission Tomography (PET) system dedicated to the study of the human brain. The system, called 4D-PET, will allow accurate imaging of brain studies due to its expected high sensitivity, high 3D spatial resolution and, by including precise photon time of flight (TOF) information, a boosted signal-to-noise ratio (SNR). The 4D-PET system incorporates an innovative detector design based on crystal slabs (semi-monolithic) that enables accurate 3D photon impact positioning (including photon Depth of Interaction (DOI) measurement), while providing a precise determination of the photon arrival time to the detector. The detector includes a novel readout system that reduces the number of detector signals in a ratio of 4:1 thus, alleviating complexity and cost. The analog output signals are fed to the TOFPET2 ASIC (PETsys) for scalability purposes. The present manuscript reports the evaluation of the 4D-PET detector, achieving best values 3D resolution values of <1.6 mm (pixelated axis), 2.7±0.5 mm (monolithic axis) and 3.4±1.1 (DOI axis) mm; 359 ± 7 ps coincidence time resolution (CTR); 10.2±1.5 % energy resolution; and sensitivity of 16.2% at the center of the scanner (simulated). Moreover, a comprehensive description of the 4D-PET architecture (that includes 320 detectors), some pictures of its mechanical assembly, and simulations on the expected image quality are provided.

11 June 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
SJSantiago Jiménez-Serrano
Santiago Jiménez-Serrano
JÁJorge Álamo
Jorge Álamo
JBJulio Barberá
Julio Barberá
ALAlejandro Lucero
Alejandro Lucero
JBJose M. Benlloch
Jose M. Benlloch
Positron Emission Tomography (PET) imaging is the molecular technique of choice for studying many illnesses, including the ones related to the brain. Nevertheless, the use of PET scanners in neurology is limited by several factors, such as their limited availability for brain imaging due to the high oncology demand for PET and the low sensitivity and poor spatial resolution in the brain of the standard PET scanners. To expand the PET application in neurology, brain-specific systems with increased clinical and physical sensitivities and higher spatial resolution are required. The present work reports on the design and development process of a compact dedicated PET scanner suitable for human brain imaging. This paper includes the description and experimental validation of the detector components and their implementation in a full-size system called 4D-PET. The detector has been designed to simultaneously provide photon DOI and TOF information. It is based on the semi-monolithic LYSO modules optically coupled to SiPMs and connected to a multiplexing readout. The analog output signals are fed to the PETsys TOFPET2 ASIC circuits enabling scalability of the readout. The evaluation of the 4D-PET modules resulted in average detector resolutions of 2.111.0 mm, 3.411.8 mm, and 38619 ps for the y-(transaxial direction), DOI-, and CTR TOF, respectively. The preliminary 4D-PET imaging performance is reported through simulations and, for the first time, through the real reconstructed images (collected in the La Fe Hospital, Valencia).

14 February 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
GCGabriel Cañizares
Gabriel Cañizares
SJSantiago Jiménez-Serrano
Santiago Jiménez-Serrano
ALAlejandro Lucero
Alejandro Lucero
CMConstantino Morera-Ballester
Constantino Morera-Ballester
EMEnrique Muñoz
Enrique Muñoz
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Total Body Positron Emission Tomography (TB-PET) scanners provide high-quality images due to the large sensitivity. Our motivation is to design a TB-PET system with up to 70 cm axial coverage that mitigates the parallax error degradation by using a detector concept based on semi-monolithic LYSO crystals. Furthermore, this detector approach allows to simultaneously reach an accurate Coincidence Time Resolution (CTR) to enhance the image quality by means of Time of Flight (TOF) reconstruction algorithms. We have simulated and compared two Positron Emission Tomography (PET) prototypes with about 70 cm but a different number of detector rings (7 vs. 5). The NEMA NU 2 2018 protocol has been implemented. By correcting the parallax error with the Depth of Interaction (DOI) information, the spatial resolution remains homogeneous and below 3 mm in the entire Field of View (FOV), differently from designs based on pixelated crystals. The sensitivity reaches values of 58 and 115 cps/kBq, for the 5 and 7 rings configurations, respectively. The Noise Equivalent Count Rate (NECR) was found at 563 kcps/mL. This value is lower than other systems, most likely due to the requirement to process a larger number of channels to characterize the DOI. Percent contrasts obtained for two different phantoms are in general beyond 80% for the largest spheres, nearly 100% for the 7 rings configuration once TOF is applied during the reconstruction process. In conclusion, although the sensitivity and NECR results for the 5-rings configuration are lower compared to the 7-rings approach, its overall performance is enhanced by the addition of TOF and parallax error correction, improving that of conventional Whole Body PET scanners (axial length: 20 – 30 cm) in terms of image quality.

29 September 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LMLaura Moliner
Laura Moliner
CCCarlos Correcher
Carlos Correcher
ABAdrian Beltrá
Adrian Beltrá
CMCesar Molinos
Cesar Molinos
TSTodd Sasser
Todd Sasser
JBJose María Benlloch
Jose María Benlloch
Objective. This work presents a comprehensive evaluation of the Bruker PET/CT Si78 preclinical imaging system, combining standardized performance assessment, inter-system reproducibility analysis, and investigation of depth-of-interaction (DOI) encoding effects on image quality. Approach. Ten independently assembled systems were characterized following the National Electrical Manufacturers Association NU 4-2008 protocol to assess spatial resolution, sensitivity, count rate performance, and image quality. Beyond standard evaluation, this study investigates the impact of DOI estimation using simulations, controlled experiments, and in vivo multi-mouse imaging. Main results. The results demonstrate consistent performance across the evaluated systems, with nearly uniform spatial resolution across the field of view (FOV), peak sensitivity around 10.5%, and low variability among systems, typically below 5%, indicating low inter-system variability across most evaluated metrics-. Continuous DOI estimation, enabled by monolithic detector technology, improves spatial resolution and its uniformity compared with dual-layer and non-DOI approaches, particularly at the periphery of the imaging volume where parallax effects are most pronounced. These improvements were consistently observed in both simulated and experimental datasets. The practical implications of DOI encoding were demonstrated in multi-animal imaging studies, where enhanced visualization of fine anatomical structures and improved quantitative accuracy were achieved. In particular, the absence of DOI information led to substantial spatially dependent quantification errors, while dual-layer DOI partially mitigated these effects. Continuous DOI estimation provided the smallest deviations and most spatially uniform results among the evaluated configurations, supporting reliable quantification in demanding applications such as brain imaging. Significance. Overall, the PET/CT Si78 system combines competitive performance with high reproducibility and advanced DOI capabilities, enabling uniform image quality across the FOV and supporting efficient multi-animal studies. These characteristics supports its use for reproducible and ethically optimized preclinical imaging aligned with the principles of reduction and refinement in animal research.