Presence of antimicrobial cocktails in the hydrological cycles is of interest because of their potential to mediate antimicrobial resistance within the natural environment. In this study, we determined the concentrations of selected antibiotics and antiretroviral drugs (ARVDs) in wastewater treatment plant (WWTP) effluent, effluent suspended particulate matter (SPM), surface waters and river sediments in Kenya in order to determine the extent of pollution within the sampled environment. Target analysis for the most common antibiotics and ARVDs was done. Sulfamethoxazole (SMX), ciprofloxacin (CIP), trimethoprim (TMP), norfloxacin (NOR), zidovidine (ZDV), lamivudine (3TC) and nevirapine (NVP) were analyzed using LC-ESI-MS/MS. Effluent aqueous phase had concentrations ranging between 1.2 µg L−1 to 956.4 µg L−1 while the effluent SPM showed higher concentrations, ranging between 2.19 mg Kg−1 and 82.26 mg Kg−1. This study shows emission of active pharmaceutical ingredients (APIs) from WWTP to the environment mainly occurs via the SPM phase, which is usually overlooked in environmental analyses. Concentrations in surface waters and river sediments ranged between 1.1 µg L−1 to 228 µg L−1 and 11 µg Kg−1 to 4125 µg Kg−1 respectively. ARVDs occurred at consistently higher concentrations than antibiotics in both the aqueous and solid samples. The wastewater treatment plants and lagoons where sludge degradation should occur, are sources of active pharmaceutical ingredients (APIs) including transformational products, nutrients and organic matter that are released back to the aqueous phase.
An analytical method for simultaneous determination of seven commonly used antibiotics and three antiretrovirals in surface water and urban wastewater at the ng L−1 level has been developed. The method involves concentration and clean-up by solid phase extraction (SPE) followed by identification and quantification by liquid chromatography tandem mass spectrometry (LC-ESI-MS/MS). The use of matrix-matched calibration curves constructed by spiking surface water was evaluated for quantification and compared with the internal standard method using isotopically labelled compounds. The method gave absolute recoveries of 41–116% with most of the compounds having recoveries >50%. The LOQs ranged from 5 to 63 ng L−1 allowing for the determination of the analytes at trace levels in the environmental samples considered. The difference in the quantification results obtained using surface water matrix-matched standards and internal standards was within a ±20% margin. The method provides an affordable and relatively fast alternative with acceptable accuracy and precision. The method was applied to study the occurrence of the target analytes in the surface water of Lake Päijänne and wastewater from the Jyväskylä wastewater treatment plant (WWTP) in Central Finland. All target compounds were detected in the WWTP streams with concentrations ranging between 10 and 570 ng L−1 while low ng L−1 levels were measured for some of the analytes in surface waters. The results institute the need for further monitoring in other WWTP streams and receiving waters as well as improvements of the wastewater treatment process with the aim of minimizing the pharmaceutical load in the effluents.
Active pharmaceutical ingredients (APIs) are only partially removed by convectional wastewater treatment plants. This study aimed at assessing the post‐treatment degradation of selected antibiotics and antiretroviral drugs by direct UV photolysis and advanced oxidation processes (UV/H2O2 and UV/Cl2) using low‐pressure mercury lamp. The rate of degradation largely followed pseudo first‐order reaction kinetics. Amongst the six studied APIs, sulfamethoxazole, ciprofloxacin and zidovudine were readily degraded by more than 90% using direct UV photolysis. Addition of Cl2 and H2O2 to the UV process led to an increase in the rate of degradation for all the compounds. The effectiveness UV/Cl2 process was affected to a greater extent by the background effluent organic matter. This implies that higher electrical energy and oxidant would be required in the UV/Cl2 process relative to UV/H2O2 process. Generally, electrical energy required to remove 90% of the target compounds increased in the order UV/H2O2 < UV/Cl2 < UV processes.
1 September 2021 in Journal of Environmental Management