1 November 2016 in NeuroImage
20 December 2001 in Magnetic Resonance in Medicine
Bolus tracking data obtained with paramagnetic intravascular tracers are commonly analyzed and quantified by the direct measurement of properties of the tissue concentration-time curve (e.g., time to peak (TTP)). The measurement of these “summary parameters” is used as an accessible alternative approach to the complex deconvolution procedure, and provides indirect measures of perfusion. However, summary parameters do not take into account differences in arterial input functions (AIFs) or residue functions (R(t)) between patients or studies. Simulations were performed to assess the variability of summary parameters over a realistic range of AIFs and for differing R(t), to establish whether they can be used as reliable measures of tissue perfusion status. Results showed that the value of each summary parameter investigated is highly dependent upon both the AIF and R(t). The referencing of summary parameters to their corresponding value in the AIF or in normal tissue is a method commonly used to normalize results, but this approach did not lead to any measures that were independent of both the AIF and R(t) in this study. The results presented here show that the use of summary parameters requires considerable caution, since tissue or patient types can easily be incorrectly classified due to the effect of variations in patient AIF and R(t). Magn Reson Med 47:61–67, 2002.
15 February 2019 in bioRxiv
MRtrix3 is an open-source, cross-platform software package for medical image processing, analysis and visualization, with a particular emphasis on the investigation of the brain using diffusion MRI. It is implemented using a fast, modular and flexible general-purpose code framework for image data access and manipulation, enabling efficient development of new applications, whilst retaining high computational performance and a consistent command-line interface between applications. In this article, we provide a high-level overview of the features of the MRtrix3 framework and general-purpose image processing applications provided with the software.
7 July 2000 in Magnetic Resonance in Medicine
Subject motion during diffusion‐weighted interleaved echo‐planar imaging causes k‐space offsets which lead to irregular sampling in the phase‐encode direction. For each image, the k‐space shifts are monitored using 2D navigator echoes, and are shown to lead to a frequent violation of the Nyquist condition when an ungated sequence is used on seven subjects. Combining data from four repeat acquisitions allows the Nyquist condition to be satisfied in all but 1% of images. Reconstruction of the irregularly‐sampled data can be performed using a matrix inversion technique. The repeated acquisitions make the inversion more stable and additionally improve the signal‐to‐noise ratio. The resultant isotropic diffusion‐weighted images and average apparent diffusion coefficient (ADC) maps show high resolution and enable clear localization of a stroke lesion. Residual ADC artifacts with a slow spatial variation are observed and assumed to originate from non‐rigid pulsatile brain motion. Magn Reson Med 44:101–109, 2000.