Joseph B. Schulz

Joseph B. Schulz

Auto-generated profile, based on publicly available information

Joseph B. Schulz

Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53706, United States of America

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2023 in Practical Radiation Oncology
Verified
Journal Article
Open access
JSJoseph B. Schulz
Joseph B. Schulz
PDPiotr Dubrowski
Piotr Dubrowski
EBErik Blomain
Erik Blomain
LMLynn Million
Lynn Million
YQYushen Qian
Yushen Qian
AYAmy S. Yu
Amy S. Yu
The goal of this study is to develop and assess the effectiveness of an affordable smartphone-based Virtual Reality (VR) patient education platform with 360-degree videos produced depicting a first-person patient perspective during the radiation therapy (RT) care path to reduce patient anxiety. and Materials Three disease site-specific (breast, pelvis, head and neck) VR-videos were filmed using a 360-degree camera to portray the first-person perspective of a patient's standard RT appointments: including a Computed Tomography (CT) simulation and the first RT treatment session. Instruction is given for possible clinical implementation. Patient participation was divided into two groups: 1) Group-A (n=28) included patients participating before simulation and later after the first treatment, and 2) Group-B (n=33) included patients participating only while undergoing treatment. Patients viewed their disease site-specific video using an inexpensive cardboard VR-viewer and their smartphone, emulating an expensive VR-headset. Surveys were administered assessing patient anxiety, comfort, satisfaction, and knowledge of RT on a 5-point Likert-type scale. Patients in Group-A and Group-B while undergoing treatment both selected their anxiety "decreased a little" in the survey, after watching the VR-video (Group-A, median on a 5-point Likert-type scale, 4 [interquartile range {IQR}, 4-5]; Group-B, 4 [IQR 4-4]). The VR aspect of the videos was especially liked by patients while undergoing treatment, with 96.4% in Group-A and 90.9% in Group-B reporting that the VR aspect of the videos was helpful. All Group-A participants believed that the VR-videos would be beneficial to new patients. Our affordable VR patient education platform effectively immerses a patient in their care path from simulation through initial treatment delivery, reducing anxiety and increasing familiarity with the treatment process.

11 January 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
JSJoseph B. Schulz
Joseph B. Schulz
PDPiotr Dubrowski
Piotr Dubrowski
CGClinton Gibson
Clinton Gibson
AYAmy S. Yu
Amy S. Yu
LSLawrie Basil Skinner
Lawrie Basil Skinner
Purpose: A well‐known limitation of multi‐leaf collimators is that they cannot easily form island blocks. This can be important in mantle region therapy. Cerrobend photon blocks, currently used for supplementary shielding, are labor‐intensive and error‐prone. To address this, an innovative, non‐toxic, automatically manufactured photon block using 3D‐printing technology is proposed, offering a patient‐specific and accurate alternative.Methods and materials: The study investigates the development of patient‐specific photon shielding blocks using 3D‐printing for three different patient cases. A 3D‐printed photon block shell filled with tungsten ball bearings (BBs) was designed to have similar dosimetric properties to Cerrobend standards. The generation of the blocks was automated using the Eclipse Scripting API and Python. Quality assurance was performed by comparing the expected and actual weight of the tungsten BBs used for shielding. Dosimetric and field geometry comparisons were conducted between 3D‐printed and Cerrobend blocks, utilizing ionization chambers, imaging, and field geometry analysis.Results: The quality assurance assessment revealed a −1.3% average difference in the mass of tungsten ball bearings for different patients. Relative dose output measurements for three patient‐specific blocks in the blocked region agreed within 2% of each other. Against the Treatment Planning System (TPS), both 3D‐printed and Cerrobend blocks agreed within 2%. For each patient, 6 MV image profiles taken through the 3D‐printed and Cerrobend blocks agreed within 1% outside high gradient regions. Jaccard distance analysis of the MV images against the TPS planned images, found Cerrobend blocks to have 15.7% dissimilarity to the TPS, while that of the 3D‐printed blocks was 6.7%.Conclusions: This study validates a novel, efficient 3D‐printing method for photon block creation in clinical settings. Despite potential limitations, the benefits include reduced manual labor, automated processes, and greater precision. It holds potential for widespread adoption in radiation therapy, furthering non‐toxic radiation shielding.

27 May 2025 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
Ethan StolenEthan Stolen
Ethan Stolen
TWTianming Wu
Tianming Wu
JSJoseph B Schulz
Joseph B Schulz
LALunya Allie
Lunya Allie
CSCaleb Song
Caleb Song
JSJames J Sohn
James J Sohn
Purpose. Total body irradiation (TBI) is a critical component in the treatment of hematological malignancies, but it carries a risk of radiation-induced lung damage. Traditional lung shields, typically made of lead or Cerrobend, are used to protect lung tissue during TBI. However, these shields require manual fabrication, present toxicity concerns, and are difficult to reproduce in the precise geometry needed for each individual patient. This study investigates the feasibility of 3D-printed bronze-polylactic acid (PLA) lung shields as a non-toxic, customizable alternative to conventional shields in TBI procedures. Materials and Methods. Bronze-PLA lung shields were 3D-printed using a PLA filament with 60% bronze powder by weight. Two thicknesses of 1.8 cm and 3.3 cm were tested. Radiation transmission was measured using a Varian TrueBeam linear accelerator (6 MV and 15 MV photon beams) at isocenter (90 cm source-to-axis distance, SAD) and extended field setup (430 cm source-to-surface distance, SSD). Measurements were repeated with a conventional wax-lead shield for comparison. Results. At 100 cm SAD and 6 MV, the 1.8 cm bronze-PLA shield transmitted 92.12% (standard error, SE = 0.03%), while the thicker (3.3 cm) bronze-PLA shield reduced transmission to 77.08% (SE = 0.02%). Under similar conditions, the wax-lead shield transmitted 86.43% (SE = 0.13%). For 15 MV beams, both the wax-lead and bronze-PLA shields exhibited higher transmission, with the 3.3 cm bronze-PLA shield providing improved attenuation relative to the thinner shield. At the extended SAD, the thinner bronze-PLA shield transmitted more than the wax-lead block, but increasing thickness consistently improved attenuation. Conclusion. The 3D-printed bronze-PLA lung shields demonstrate promising potential in TBI procedures, offering advantages in customization, reduced toxicity, and improved workflow efficiency. While differences in transmission characteristics were observed, particularly at higher energies and extended SDD, these findings provide a foundation for further optimization of 3D-printed shielding for TBI protocols.

7 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
PLPhoebe Loo
Phoebe Loo
MPMargaret Pan
Margaret Pan
Man ZhaoMan Zhao
Man Zhao
SMSTAVROS MELEMENIDIS
STAVROS MELEMENIDIS
JSJoseph Schulz
Joseph Schulz
ERErinn Rankin
Erinn Rankin
This study demonstrates that FLASH radiotherapy reduces radiation-induced oral mucositis and tongue ulceration compared to conventional irradiation in both wild-type and Fanca-deficient mice. FLASH also decreased persistent gH2AX DNA damage within the tongue's basal epithelium, indicating that its normal tissue-sparing effects remain preserved despite impaired Fanconi anemia DNA repair pathways.