1 October 2025 in Quantitative Imaging in Medicine and Surgery
Background: While conventional magnetic resonance imaging (MRI) in multiple sclerosis (MS) primarily evaluates focal lesions, the normal-appearing white matter (NAWM) encompasses brain tissue that appears radiologically normal but harbors subtle pathological changes that contribute to the overall disease burden. The aim of this study was to investigate the role of T1rho MRI in characterising distance-dependent microstructural changes in the perilesional NAWM in patients with relapsing-remitting multiple sclerosis (RRMS). Methods: T1rho and diffusion tensor imaging (DTI) images were acquired from 30 patients with RRMS and 30 age-matched healthy controls. A total of 217 non-contrast-enhancing MS lesions were identified, and five perilesional layers were delineated from the lesion margins. T1rho values in the intralesional and perilesional regions in MS patients and the corresponding normal white matter of controls were quantified and compared. Results: T1rho values progressively decreased from the lesional regions (111.82±27.58 ms) to the perilesional layer 5 (78.06±4.76 ms) (P value <0.05). Significant correlations were found between T1rho values and mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) in the perilesional areas, with a pattern of progressively lower correlation coefficients (r, 0.23 to 0.73, P value <0.01) between T1rho values and the DTI metrics as the distance from the lesion increased. Conclusions: Our findings suggest that T1rho is a sensitive method for the detection of microstructural changes in the NAWM, and may provide valuable information about the spatial extent and severity of these changes.
5 August 2025 in Magnetic Resonance in Medicine
Purpose: Recent studies have shown that spin‐lock MRI can simplify quantitative magnetization transfer (MT) by eliminating its dependency on water pool parameters, removing the need for a T1 map in macromolecular proton fraction (MPF) quantification. However, its application is often limited by the requirement for long radiofrequency (RF) pulse durations, which are constrained by RF hardware capabilities despite remaining within specific absorption rate (SAR) safety limits.Methods: To address this challenge, we propose a novel method, MPF mapping using pulsed spin‐lock (MPF‐PSL). MPF‐PSL employs a pulsed spin‐lock train with intermittent free precession periods, enabling extended total spin‐lock durations without exceeding hardware and specific absorption rate limits. A comprehensive analytical framework was developed to model the magnetization dynamics of the two‐pool MT system under pulsed spin‐lock, demonstrating that MPF‐PSL achieves MT‐specific quantification while minimizing confounding effects from the water pool. The proposed method is validated with Bloch–McConnell simulations, phantoms, and in vivo studies at 3T.Results: Both Bloch–McConnell simulations and phantom validation demonstrated that MPF‐PSL exhibits insensitivity to water pool parameters while enabling robust MPF quantification. In vivo validation studies confirmed the method's clinical utility in detecting collagen deposition in patients with liver fibrosis.Conclusion: MPF‐PSL presents a practical solution for quantitative MT imaging, with strong potential for clinical applications.
5 August 2025 in Magnetic Resonance in Medicine
Purpose: To propose and evaluate an accelerated quantification method that combines ‐weighted fast spin echo (FSE) images and proton density (PD)‐weighted anatomical FSE images, leveraging deep learning models for mapping. The goal is to reduce scan time and facilitate integration into routine clinical workflows for osteoarthritis (OA) assessment.Methods: This retrospective study utilized MRI data from 40 participants (30 OA patients and 10 healthy volunteers). A volume of PD‐weighted anatomical FSE images and a volume of ‐weighted images acquired at a non‐zero spin‐lock time were used as input to train deep learning models, including a 2D U‐Net and a multi‐layer perceptron (MLP). maps generated by these models were compared with ground truth maps derived from a traditional non‐linear least squares (NLLS) fitting method using four ‐weighted images. Evaluation metrics included mean absolute error (MAE), mean absolute percentage error (MAPE), regional error (RE), and regional percentage error (RPE).Results: The best‐performed deep learning models achieved RPEs below 5% across all evaluated scenarios. This performance was consistent even in reduced acquisition settings that included only one PD‐weighted image and one ‐weighted image, where NLLS methods cannot be applied. Furthermore, the results were comparable to those obtained with NLLS when longer acquisitions with four ‐weighted images were used.Conclusion: The proposed approach enables efficient mapping using PD‐weighted anatomical images, reducing scan time while maintaining clinical standards. This method has the potential to facilitate the integration of quantitative MRI techniques into routine clinical practice, benefiting OA diagnosis and monitoring.