29 April 2020 in IEEE Transactions on Power Systems
Radiality constraints are involved in both distribution system restoration and reconfiguration problems. However, a set of widely used radiality constraints, i.e., the spanning tree (ST) constraints, has its limitations which have not been well recognized. In this letter, the limitation of the ST constraints is analyzed and an effective set of constraints, referred to as the single-commodity flow constraints, is presented. Furthermore, a combined set of constraints is proposed and case studies indicate that the combined constraints can gain computational efficiency in the reconfiguration problem. Recommendations on the use of radiality constraints are also provided.
12 July 2019 in IEEE Transactions on Smart Grid
This paper presents a two-layer distributed cooperative control method for networked microgrid (NMG) systems, taking into account the proprietary nature of microgrid (MG) owners. The proposed control architecture consists of an MG-control layer and an NMG-control layer. In the MG layer, the primary and distributed secondary controls realize accurate power sharing among distributed generators (DGs) and the frequency/voltage reference following within each MG. In the NMG layer, the tertiary control enables regulation of the power flowing through the point of common coupling (PCC) of each MG in a decentralized manner. Furthermore, distributed quaternary control restores the system frequency and critical bus voltage to their nominal values and ensures accurate power sharing among MGs. A small-signal dynamic model is developed to evaluate the dynamic performance of NMG systems with the proposed control method. Time-domain simulations and experiments on NMG test systems are performed to validate the effectiveness of the proposed method.
7 February 2020 in IEEE Transactions on Power Electronics
16 August 2021 in IEEE Transactions on Smart Grid
A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is to provide electricity, water, and natural gas supplies to critical customers in the desired ratio according to their needs after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. The characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to nonconvex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on electricity-water-gas integrated systems, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation.
22 October 2019 in IEEE Transactions on Industrial Electronics
4 February 2020 in IEEE Access
Accurate fault location is crucial for finding and clearing faults in distribution networks. It can help to reduce the loss of power failure and ensure safe and stable operation. Without efficient observation points and the lack of phase angle information, traditional fault location methods of distribution networks usually have large errors. As the application of μPMUs in the distribution network becomes more and more common, voltage and current waveforms, as well as phase angle can be recorded and provide more information for accurate fault location. In this paper, an intelligent location method is proposed to pinpoint the fault location based on the information of μPMUs which are properly allocated. The fault section is firstly determined by comparing the zero-sequence current waveforms on both sides of the fault section. Then, a Stack Auto-Encoder (SAE) is modeled to provide an end-to-end solution to pinpoint fault point with the voltage and current phasors. Finally, the performance of the proposed method is tested by a simulated distribution network on the platform of PSCAD. The results show that the proposed method is effective in locating faults and can withstand the effects of transition resistance, fault type, and noise. Compared to another popular method, the proposed method shows better location accuracy.