16 August 2021 in IEEE Transactions on Smart Grid
A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is to provide electricity, water, and natural gas supplies to critical customers in the desired ratio according to their needs after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. The characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to nonconvex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on electricity-water-gas integrated systems, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation.
22 October 2019 in IEEE Transactions on Industrial Electronics
28 July 2021 in IEEE Transactions on Industrial Electronics
DC short-circuit current calculation is necessary to design and protect modular multilevel converter-based (MMC-based) multiterminal dc (MTDC) grids. In this article, a general and analytical short-circuit current calculation method is proposed for bipolar MTDC grids. For pole-to-pole (P2P) faults, the superposed fault equivalent network of the MTDC grid is first developed in the frequency-domain. Then, a decoupling method based on the network inductance ratio is proposed, which simplifies the high-order network into the superposition of several independent two-order RLC circuits. As a result, the short-circuit current can be expressed as the sum of the currents of these RLC circuits. For pole-to-ground (P2G) faults, the phase-domain dc line impedance considering the coupling effects is determined based on its modal-domain parameters, so that the P2G fault current can be calculated using the method of the P2P fault. The proposed method’s effectiveness is verified through simulations and experiments, and the calculation error is classified and analyzed. Compared with the existing methods, the proposed method is more accessible, more accurate, and available for hand-solution.
7 May 2012 in Journal of Dynamic Systems, Measurement, and Control
This paper proposes a new approximation scheme which is an extension to the well-established Charef’s approximation method for fractional order systems. The method relaxes the constraints on the locations of the pole-zero pairs of the approximate system, which provides more flexibility and space for approximate system to approach the original system as close as possible. The approximate system based on an optimization process performs not only a good magnitude fitting but also a good phase fitting. The benefits from using the proposed scheme are illustrated by numerical examples in frequency domains.
10 November 2022 in IEEE Transactions on Power Delivery
Effective DC fault identification is very important for a half-bridge modular multi-level converter (HB-MMC) based high voltage direct current (HVDC) grid. The performance of the traditional protection principles lacks reliability and sensitivity, and there is a further limitation under the current limiting strategies. To address the problem, a scheme coordinating the control and protection is proposed, which actively creates the known feature for fault identification and limits the fault current at the same time. In this paper, the characteristics of the input impedance phase under different faults are analyzed in various frequency bands. Based on the analysis of the input impedance phase, the converter switches the control mode and generates a characteristic signal at a particular frequency after fault detection. Then, the Prony algorithm is employed to acquire the phase information at the injection frequency. Finally, the faulty zone can be identified by the value of the input impedance phase. This active injection protection scheme is applicable to identify different faults, verified in PSCAD/EMTDC, and tested by hardware-in-the-loop simulation in RTDS.
4 February 2022 in IEEE Transactions on Power Delivery
Hybrid high voltage direct current systems utilized for bulk-power transmission have recently attracted more attention. The overhead lines (OHLs) are mainly used for the implementation of such systems due to their outstanding economic advantages. However, OHLs are vulnerable to temporary faults, jeopardizing the safe and reliable operation of the network. The resiliency to the line faults is of considerable significance to the power transmission. This paper proposes a fault property identification strategy based on the Pearson correlation coefficient for the LCC-MMC hybrid HVDC system which can differentiate temporary and permanent faults. To achieve this, a voltage signal is injected into the faulty line by decreasing the firing angles of the LCC-based rectifier. Based on the established OHLs model and the injected signal, an estimated backward travelling wave can be accurately calculated. The fault property is identified by comparing the wave difference of the real backward travelling wave and the estimated backward travelling wave. The proposed strategy has a high accuracy since all influencing factors including the fault resistance, fault distance, and line parameters have been taken into account. Finally, to verify the efficacy of the proposed algorithm, several simulations have been performed using PSCAD/EMTDC. The simulation results show that the proposed algorithm can effectively distinguish the fault property.