The article is devoted to the development of a surrogate model as an element of a computer vision system to identify internal defects in insulating parts of complex shape. To analyze the electrophysical characteristics of high-voltage insulators with defects, the principles of optimal construction of a physical model necessary to obtain simulation data are determined. A set of functional dependencies for the analysis of the electrical strength of the sample and the principles of selecting arguments for these dependencies are also defined. Using the example of a glass part of the PS-70E insulator, it has been shown that a numerical model in the form of a polynomial of five seventh-order variables, taking into account the change in the shape of elliptical gas inclusions and their distribution, is sufficient to analyze the electrical strength of the insulator. The relative error in determining the main characteristics of the electric field in the defect based on the results of simulation modeling and calculation using a surrogate model is no more than 10%. The use of a surrogate model makes it possible to identify areas for which the maximum electric field strength will be observed in defects, which makes it possible for the computer vision system to assess the potential danger of defects. Using the polynomial form of the surrogate model simplifies the process of creating a model, since the construction algorithm is deterministic. This advantage can be used in the construction of surrogate models of insulation structures, since their physical properties are sufficiently homogeneous throughout the entire product and they can be approximated by a polynomial function of a small degree. Also, the advantage of the polynomial model was determined by the relative simplicity of obtaining simulation data. Статья посвящена построению суррогатной модели как элементу системы технического зрения для выявления внутренних дефектов в изоляционных деталях сложной формы. Для анализа электрофизических характеристик высоковольтных изоляторов с дефектами определены принципы оптимального построения физической модели, необходимой для получения имитационных данных. Также определен набор функциональных зависимостей для анализа электрической прочности образца и принципы подбора аргументов этих зависимостей. На примере стеклянной детали изолятора ПС-70Е показано, что для анализа электрической прочности изолятора достаточно суррогатной модели в виде полинома пяти переменных седьмого порядка, учитывающей изменение формы эллиптических газовых включений и их расположение. Относительная ошибка в определении основных характеристик электрического поля в дефекте по результатам имитационного моделирования и расчета по суррогатной модели составляет не более 10%. Использование суррогатной модели позволяет выявить области, для которых в дефектах будет наблюдаться максимальная напряженность электрического поля, что дает возможность системе технического зрения оценивать потенциальную опасность дефектов. Использование полиномиальной формы суррогатной модели упрощает процесс создания модели, поскольку алгоритм построения имеет детерминированный характер. Указанное преимущество можно использовать при построении суррогатных моделей изоляционных конструкций, поскольку их физические свойства достаточно однородны во всем изделии и их можно аппроксимировать полиномиальной функцией небольшой степени. Также преимущество полиномиальной модели определялось относительной простотой получения данных имитационного моделирования.

1 January 2024 in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
Verified
Journal Article
Open access
PDF file
AKAnton V. Korzhov
Anton V. Korzhov
ВСВладимир Анатольевич Сурин
Владимир Анатольевич Сурин
МЧМария Александровна Ческидова
Мария Александровна Ческидова
ПЛПетр Владимирович Лонзингер
Петр Владимирович Лонзингер
ВСВалерий Иванович Сафонов
Валерий Иванович Сафонов
КБКирилл Николаевич Белов
Кирилл Николаевич Белов
The article presents an algorithm for detecting defects in glass insulators using computer vision. Insulators, which are key elements of electrical networks, are subject to various defects, such as bubbles, chips and deformations. Such damage can significantly reduce the service life of insulators. In traditional production conditions, these defects are detected manually, which reduces productivity and increases the likelihood of human factor-based errors. To solve the problem related to manual control restraints, the authors developed an algorithm based on the use of a neural network. The main task of the algorithm is to automatically identify defects that have a significant impact on the mechanical and electrical insulation properties of products. The authors collected a data set for training the neural network and supplemented it with generated images to increase the sample of the location and shape of the considered defects. The paper describes in detail the steps of data preprocessing, including augmenting the contrast to increase the detectability of defects and reducing noise. Fragmenting is described to process defects of various sizes and shapes. Such fragmenting allows detecting defects of different sizes relative to the insulator size.

1 January 2024 in Image Journal of Advanced Materials and Technologies
Verified
Journal Article
Open access
ESEvgeny Sheshin
Evgeny Sheshin
NKNataliya D Kundikova
Nataliya D Kundikova
VKViktor Kireev
Viktor Kireev
KBKirill Belov
Kirill Belov
FMFung Man
Fung Man
DPDanila Prosekov
Danila Prosekov
Field emission and structural characteristics of carbon nanotube fibers, polyacrylonitrile fibers, pyrolytic graphite and micrograined dense graphite were experimentally studied before and after their operation as a field emission cathode using registration of the current-voltage characteristics, optical microscopy, scanning electron microscopy and Raman spectroscopy in the spectral range from 1000 to 2000 cm–1. The experiments showed large and small structural rearrangements of carbon-containing cathodes and their surfaces in the process of field emission. In addition to lines of the Raman spectra with frequency maxima in the known ranges: G (1581–1599 cm–1), D (1363–1374 cm–1) and D' (1619– 1626 cm–1), characteristic of carbon materials, a line was detected in the range 1450–1480 cm–1, which is observed in the starting materials of pyrolytic graphite, carbon nanotube fibers and persists after operation, and also appears in a sample of micro-grained dense graphite after operation as a cathode. The relative integral intensity of line D in pyrolytic graphite, micrograined dense graphite, and carbon nanotube fibers undergoes the greatest change. In pyrolytic graphite and carbon nanotube fibers its increase is observed, and in micrograined dense graphite its decrease is observed after operation as a cathode. This made it possible to use the relative integral intensity of the D-line to quantify the change in the surface properties of carbon materials as a result of field emission when using these materials as cathodes, in particular to assess changes in crystallite sizes. Thus, the possibility of using Raman spectra to control the surface structure of carboncontaining materials has been demonstrated, which significantly facilitates the possibility of further analysis of the relationship between the surface structure and its emission characteristics. The prospects for improving the field emission characteristics of carbon-containing cathodes were discussed.

1 January 2025 in Bulletin of the South Ural State University Series "Power Engineering"
Verified
Journal Article
Closed access
PDF file
SUSouth Ural State University
South Ural State University
AKAnton V. Korzhov
Anton V. Korzhov
PLP.V. Lonzinger
P.V. Lonzinger
VSV.I. Safonov
V.I. Safonov
VSV.A. Surin
V.A. Surin
KBK.N. Belov
K.N. Belov
The article is devoted to the construction of surrogate models as a tool for assessing the influence of the properties of materials of insulating structures and the defects present in them, the geometry of insulating structures, on the electrical strength in the area of the defect location. Using the example of a glass part of the PS-70E (U70) insulator, it is shown that a surrogate model in the form of a polynomial of four seventh-order variables, which takes into account changes in the dielectric permittivity and specific conductivities of the model materials, is sufficient to analyze the electrical strength in the area of the defect location when the properties of materials change. The relative error in determining the electric field based on the results of simulation modeling and calculation using the surrogate model is no more than 11.2% and 10.7% for the maximum and minimum electric field strengths in the defect, respectively. It is shown that the dielectric constant of the substance of the insulating structure has a significant effect on the field strength only when the permeability of the defect substance is less than 6, which is typical for defects in the form of gas inclusions. The change in the characteristics of the field in the defect, depending on the geometry of the structure, was also considered using the example of the head of the glass part of the PS-70E insulator. The change in geometry was studied at different values of the amplitudes of the first spatial harmonics of the forming boundaries with a simultaneous change in the location of the spherical defect inside the structure. It is shown that in this case, a polynomial of 5 degrees of 4 variables is sufficient to construct a surrogate model. The maximum margin of error is no more than 7.6%. The analysis of the dependences of the field strengths inside the defect in the considered surrogate models, as well as in the obtained model, suggests that defects in high-voltage insulators ranging in size from 0.1 to 2 mm can be considered potentially dangerous. Статья посвящена построению суррогатных моделей как инструменту оценки влияния свойств материалов изоляционных конструкций и присутствующих в них дефектов, геометрии изоляционных конструкций, на электрическую прочность в области расположения дефекта. На примере стеклянной детали изолятора ПС-70Е показано, что для анализа электрической прочности в области расположения дефекта при изменении свойств материалов достаточно суррогатной модели в виде полинома четырех переменных седьмого порядка, учитывающей изменение диэлектрических проницаемостей и удельных проводимостей материалов модели. Относительная ошибка в определении электрического поля по результатам имитационного моделирования и расчета по суррогатной модели составляет не более 11,2% и 10,7% для максимальной и минимальной напряженности электрического поля в дефекте соответственно. Показано, что диэлектрическая проницаемость вещества изоляционной конструкции оказывает существенное влияние на напряженность поля только при проницаемостях вещества дефекта, меньших 6, что характерно для дефектов в виде газовых включений. Изменение характеристик поля в дефекте в зависимости от геометрии конструкции рассматривалось также на примере головки стеклянной детали изолятора ПС-70Е. Изменение геометрии изучалось при различных значениях амплитуд первых пространственных гармоник образующих границ с одновременным изменением расположения сферического дефекта внутри конструкции. Показано, что для построения суррогатной модели в этом случае достаточно полинома 5 степени 4 переменных. Максимальная погрешность при этом составляет не более 7,6%. Анализ зависимостей напряженностей поля внутри дефекта в рассматриваемых суррогатных моделях, а также в полученной ранее модели, позволяет утверждать, что потенциально опасными могут считаться дефекты в высоковольтных изоляторах размерами от 0,1 до 2 мм.

1 January 2025 in Bulletin of the South Ural State University Series "Power Engineering"
Verified
Journal Article
Open access
PDF file
SUSouth Ural State University
South Ural State University
AKAnton V. Korzhov
Anton V. Korzhov
MKM.E. Korzhova
M.E. Korzhova
PLP.V. Lonzinger
P.V. Lonzinger
VSV.A. Surin
V.A. Surin
VSV.I. Safonov
V.I. Safonov
The article considers the formation of a calculation model for assessing the hazard of 1–2 mm air inclu-sions in glass parts of PS-70E (U70) insulators. The model includes fuzzy sets for the following input variables: defect size, distance from the part axis to the defect center, position of the defect center. The hazard of defects was assessed using the Mamdani algorithm based on the obtained model. The calculation results were verified based on the calculation of electric field distribution patterns. The article shows that the calculation model allows for the correct classification of defects for the considered examples in terms of the hazard of electrical strength failures. The developed model can be improved by expanding its generalizing ability to other types of defects and boundaries of glass parts. Given the expected performance accuracy, the model can be used to form training data for a neural network able to assess the hazard of potential defects in terms of electrical strength failures based on the images of glass parts. Рассматривается формирование расчетной модели для оценки опасности воздушных включений диаметрами от 1 до 2 мм в стеклянных деталях изоляторов марки ПС-70Е. В состав модели входят нечеткие множества для входных переменных: размер дефекта, расстояние от оси детали до центра дефекта, положение центра дефекта. С использованием алгоритма Мамдани на основе полученной модели проведена оценка опасности дефектов. Результаты расчета были верифицированы на основе расчета картин распределения электрического поля. Показано, что для рассмотренных примеров расчетная модель позволяет проводить правильную классификацию дефектов с точки зрения опасности нарушения электрической прочности. Разработанная модель может быть улучшена путем расширения ее обобщающей способности на другие разновидности дефектов и виды границ стеклянных деталей. При обеспечении ожидаемой точности работы модели возможно формирование с ее помощью обучающих данных для нейронной сети, способной по изображениям стеклянных деталей формировать оценку опасности потенциальных дефектов с точки зрения нарушения электрической прочности.