9 November 2017 in IEEE Journal of Solid-State Circuits
We report an area- and energy-efficient integrated circuit architecture of a 128-channel Δ-modulated Δ Σ analog front-end (Δ-Δ Σ AFE) for 1024-channel 3-D massive-parallel neural recording microsystems. Our platform has adopted a modularity of 128 channels and consists of eight multi-shank neural probes connected to individual AFEs through interposers in a small form factor. In order to reduce both area and energy consumption in the recording circuits, we implemented a spectrum equalization scheme to take advantage of the inherent spectral characteristics of neural signals, where most of the energy is confined in low frequencies and follows a ~1/f curve in the spectrum. This allows us to implement the AFE with a relaxed dynamic range by ~30 dB, thereby contributing to the significant reduction of both energy and area without sacrificing signal integrity. The Δ -Δ Σ AFE was fabricated using 0.18-μm CMOS processes. The single-channel AFE consumes 3.05 μW from 0.5 and 1.0 V supplies in an area of 0.05 mm² with 63.8-dB signal-to-noise-and-distortion ratio, 3.02 noise efficiency factor (NEF), and 4.56 NEF²VDD. We also have achieved an energy-area product, a figure-of-merit most critical for massive-parallel neural recording systems, of 6.34 fJ/C·s·,mm².
30 June 2021 in IEEE Transactions on Biomedical Engineering
We report a miniaturized, minimally invasive high-density neural recording interface that occupies only a 1.53 mm2 footprint for hybrid integration of a flexible probe and a 256-channel integrated circuit chip. To achieve such a compact form factor, we developed a custom flip-chip bonding technique using anisotropic conductive film and analog circuit-under-pad in a tiny pitch of 75 m. To enhance signal-to-noise ratios, we applied a reference-replica topology that can provide the matched input impedance for signal and reference paths in low-noise aimpliers (LNAs). The analog front-end (AFE) consists of LNAs, buffers, programmable gain amplifiers, 10b ADCs, a reference generator, a digital controller, and serial-peripheral interfaces (SPIs). The AFE consumes 51.92 W from 1.2 V and 1.8 V supplies in an area of 0.0161 mm2 per channel, implemented in a 180 nm CMOS process. The AFE shows > 60 dB mid-band CMRR, 6.32 Vrms input-referred noise from 0.5 Hz to 10 kHz, and 48 M input impedance at 1 kHz. The fabricated AFE chip was directly flip-chip bonded with a 256-channel flexible polyimide neural probe and assembled in a tiny head-stage PCB. Full functionalities of the fabricated 256-channel interface were validated in both in vitro and in vivo experiments, demonstrating the presented hybrid neural recording interface is suitable for various neuroscience studies in the quest of large scale, miniaturized recording systems.
20 November 2020 in Science Advances
Needle-compatible miniaturized optoelectronic sensor may help pancreatic cancer diagnosis.
18 March 2021 in Journal of Neural Engineering
Objective . Dorsal root ganglia (DRG) are promising sites for recording sensory activity. Current technologies for DRG recording are stiff and typically do not have sufficient site density for high-fidelity neural data techniques. Approach . In acute experiments, we demonstrate single-unit neural recordings in sacral DRG of anesthetized felines using a 4.5 µ m thick, high-density flexible polyimide microelectrode array with 60 sites and 30–40 µ m site spacing. We delivered arrays into DRG with ultrananocrystalline diamond shuttles designed for high stiffness affording a smaller footprint. We recorded neural activity during sensory activation, including cutaneous brushing and bladder filling, as well as during electrical stimulation of the pudendal nerve and anal sphincter. We used specialized neural signal analysis software to sort densely packed neural signals. Main results . We successfully delivered arrays in five of six experiments and recorded single-unit sensory activity in four experiments. The median neural signal amplitude was 55 μ V peak-to-peak and the maximum unique units recorded at one array position was 260, with 157 driven by sensory or electrical stimulation. In one experiment, we used the neural analysis software to track eight sorted single units as the array was retracted ∼500 μ m. Significance . This study is the first demonstration of ultrathin, flexible, high-density electronics delivered into DRG, with capabilities for recording and tracking sensory information that are a significant improvement over conventional DRG interfaces.
16 October 2018 in bioRxiv
The ability to deliver flexible biosensors through the toughest membranes of the central and peripheral nervous system is an important challenge in neuroscience and neural engineering. Bioelectronic devices implanted through dura mater and thick epineurium would ideally create minimal compression and acute damage as they reach the neurons of interest. We demonstrate that a three-dimensional diamond shuttle can be easily made with a vertical support to deliver ultra-compliant polymer microelectrodes (4.5 μm thick) in-vivo through dura mater and thick epineurium. The diamond shuttle has 54% less cross-sectional area than an equivalently stiff silicon shuttle, which we simulated will result in a 37% reduction in blood vessel damage. We also discovered that higher frequency oscillation of the shuttle (200 Hz) significantly reduced tissue compression regardless of the insertion speed, while slow speeds also independently reduced tissue compression. Insertion and recording performance are demonstrated in rat and feline models, but the large design space of these tools are suitable for research in a variety of animal models and nervous system targets.