14 April 2025 in Brain Stimulation
In transcranial magnetic stimulation (TMS), a pulse of current driven through a coil on the scalp induces an electric field on the cortex, eliciting neuronal activation. Multi-locus TMS (mTMS) uses multiple coils to generate various electric field patterns, enabling electronic control of stimulation location and orientation. However, changing the stimulation target with mTMS can take up to a few seconds when the driving voltages are adjusted for each coil. To investigate whether multi-coil TMS combined with pulse-width modulation (PWM) in the microsecond scale could be used to overcome the issue of rapid pulse delivery to different cortical targets. We devised a methodology to generate and drive PWM approximations of given reference pulses. We compared resting motor thresholds (RMTs) and motor evoked potentials (MEPs) between trapezoidal and PWM pulses in several multi-coil targeting scenarios. The cortical electric field of PWM pulses had high temporal complexity, but the pulse types showed no statistically significant differences when stimulating with 2- or 3-coil combinations. With PWM pulses using five coils, the RMT increased by 9% (p = 0.06), and MEP amplitudes decreased by 20% with stimulation doses over 120% RMT (p < 0.05). Motor responses with trapezoidal and PWM pulses were equivalent when using two or three coils concurrently, but some differences were found with five coils. Using PWM with multi-coil TMS device to control the stimulation targets in millisecond-scale is feasible, although more research is needed to understand the neurophysiological effects of increasing coil count.
13 August 2025 in Physics in Medicine & Biology
Background. Multi-locus TMS (mTMS) enables precise electronic control of brain stimulation targeting, eliminating the need for physical coil movement. However, with a small number of coils, the stimulation area is constrained, and manual handling of the coil array is cumbersome. Combining electronic mTMS targeting with robotics enables automated, user-independent, and precise brain stimulation protocols. Objective. To characterize an open-source electronic–robotic mTMS platform for rapid and accurate brain stimulation targeting. Methods. We developed an automated robotic mTMS positioning platform. We used a 5-coil mTMS device coupled to a collaborative robot. The stimulation targeting accuracy of the system was quantified with a TMS characterizer that measures the TMS-induced electric field (E-field) on a model of a spherical cortex. The induced E-field distortion generated by robot coupling was evaluated for each coil. We compared the repositioning accuracy of robotic–electronic system to the conventional manual positioning. Results. Our collaborative-robot-based system offers submillimeter precision and autonomy in positioning mTMS coil sets. The electronic–robotic mTMS platform was approximately 1.8 mm and 1.0° more accurate than the conventional manual positioning. Integrating robotics and mTMS automates brain stimulation procedures, resulting in minimal reliance on user expertise and subjective analysis. Conclusion. Our open-source platform combining rapid mTMS targeting with robotic precision enhances the safety and reproducibility of TMS, enabling more efficient and reliable outcomes than previous techniques.
31 October 2025 in NeuroImage
Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) and electromyography (EMG) provides a unique window into instantaneous cortical and corticospinal excitability states. We investigated 50 healthy participants to determine how fluctuations in pre-stimulus brain activity influence single-trial TMS-evoked potentials (TEPs) and motor-evoked potentials (MEPs). We developed a novel automated source-level TEP extraction method using individualized spatiotemporal priors that is robust against poor single-trial signal-to-noise ratios (SNRs) and ongoing oscillations. TEP and MEP amplitudes were predicted with linear mixed-effects models based on pre-stimulation EEG band-powers (theta to gamma), while accounting for temporal drifts (within-session trends), coil control, and inter-subject differences. We found that higher pre-stimulus sensorimotor alpha, beta, and gamma power were each associated with larger TEPs, indicating a more excitable cortical state. Increases in alpha and gamma power immediately before stimulation specifically predicted larger MEPs, reflecting increased corticospinal excitability. These results reveal relationships between ongoing oscillatory brain states and TMS response amplitudes, identifying EEG biomarkers of high- and low-excitability states. In conclusion, our study demonstrates the feasibility of single-trial source-level TMS-EEG analysis and shows that spontaneous alpha-, beta-, and gamma-band oscillations modulate motor cortical and corticospinal responsiveness. These findings can contribute to EEG-informed, brain-state-dependent TMS protocols in optimizing neuromodulatory interventions in clinical and research applications.
25 September 2025 in bioRxiv
Determining the optimal stimulation target for motor responses (motor hotspot) and the required intensity for reliably eliciting said responses (motor threshold) are common procedures in transcranial magnetic stimulation (TMS) research and treatments. However, the procedures for determining them are user-dependent, slow, and lack standardization, leading to long stimulation sessions with potentially inadequate outcomes. Partially automated algorithms for determining the motor threshold have been developed, but the motor hotspot is still largely mapped by hand. Automating the hotspot mapping will accelerate the process and improve standardization and accuracy. We developed a fully automated algorithm for finding the motor hotspot with multi-locus TMS and Bayesian optimization. Tested online in five healthy participants, the algorithm located motor hotspots with (mean ± 95% CI) 2.1 ± 0.7 mm and 6 ± 2° difference from the global best target with only (mean) 47 stimuli. This is a significant improvement from previous motor-mapping algorithms, which do not optimize for stimulation location and orientation simultaneously. This accurate, fast, and user-independent procedure paves the way for faster experimental processes and more streamlined clinical applications.
1 May 2026 in Brain Stimulation
A key limitation of transcranial magnetic stimulation (TMS) is the lack of real-time, individualized feedback about where the brain is being stimulated, leading to inaccurate assumptions about the underlying affected areas. This uncertainty contributes to poor reproducibility, limited interpretability, and variable efficacy across individuals and sessions. We aimed to develop and validate a neuronavigation system with real-time electric field (E-field) computation and visualization on realistic head models, with extended support for multi-locus TMS (mTMS). We designed and built a software framework that integrates an E-field solver with the InVesalius navigation software, introducing a GUI and a workflow that support real-time E-field visualization and quantitative analysis. We characterized our E-field neuronavigation performance and demonstrated it in vivo using a commercial figure-of-eight coil and a robotic-guided 5-coil mTMS. We also quantified precision and accuracy errors, spatial root-mean-square error (RMSE), and maximum absolute gain (MAG). Real-time visualization of electronically shifted E-fields without moving the coil was demonstrated by mapping the precentral gyrus with mTMS and recording motor evoked potentials (MEPs) from finger muscles. The time required for building the boundary element models was 27 s, and the E-field module latency during navigation was approximately 24 ms per coil position. In vivo estimates of E-field distribution during TMS coil repositioning showed low precision errors (0.9-2%) and accuracy errors (2.2-4.9%). MAG values indicated consistent E-field amplitudes relative to reference fields, and RMSE values remained low (< 2.2 V/m) with consistent MEP responses. In mTMS visualization, the MEP amplitude decreased as the electronically shifted E-field moved away from the hotspot. Our system enables real-time, individualized E-field visualization during TMS, accounting for cortical folding and offering features that simplify, standardize, and improve the reproducibility of the TMS process.