Manuel Hegelheimer

Manuel Hegelheimer

Auto-generated profile, based on publicly available information

Manuel Hegelheimer

Helmholtz-Institute Erlangen-Nürnberg for Renewable Energy (IET-2), Forschungszentrum Jülich, Cauerstr. 1, Erlangen 91058, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2020 in ACS Applied Energy Materials
Verified
Journal Article
Closed access
BMBritta Mayerhöfer
Britta Mayerhöfer
DMDavid McLaughlin
David McLaughlin
TBThomas Böhm
Thomas Böhm
MHManuel Hegelheimer
Manuel Hegelheimer
DSDominik Seeberger
Dominik Seeberger
STSimon Thiele
Simon Thiele

1 January 2022 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
BMBritta Mayerhöfer
Britta Mayerhöfer
FSFlorian D. Speck
Florian D. Speck
MHManuel Hegelheimer
Manuel Hegelheimer
MBMarkus Bierling
Markus Bierling
DADunia Abbas
Dunia Abbas
RPRetha Peach
Retha Peach

11 October 2023 in Journal of Materials Chemistry A
Verified
Journal Article
Open access
PDF file
LHLinus Hager
Linus Hager
MHManuel Hegelheimer
Manuel Hegelheimer
JSJulian Stonawski
Julian Stonawski
AFAnna T. S. Freiberg
Anna T. S. Freiberg
CJCamilo Jaramillo-Hernández
Camilo Jaramillo-Hernández
Jochen KerresJochen Kerres
Jochen Kerres
We report the synthesis of a polystyrene-based anion exchange polymer bearing the cationic charge at a C6-spacer. The polymer is prepared by a functionalized monomer strategy. First, a copper halide catalyzed C–C coupling reaction between a styryl Grignard and 1,6-dibromohexane is applied, followed by quaternization with N-methylpiperidine and free radical polymerization. The novel polymer is blended with the polybenzimidazole O-PBI to yield mechanically stable blend membranes representing a new class of anion exchange membranes. In this regard, the ratio of the novel anion exchange polymer to O-PBI is varied to study the influence on water uptake and ionic conductivity. Blend membranes with IECs between 1.58 meq. OH− g−1 and 2.20 meq. OH− g−1 are prepared. The latter shows excellent performance in AEMWE, reaching 2.0 A cm−2 below 1.8 V in 1 M KOH at 70 °C, with a minor degradation rate from the start. The blend membranes show no conductivity loss after immersion in 1 M KOH at 85 °C for six weeks indicating high alkaline stability.

1 December 2025 in ACS Applied Energy Materials
Verified
Journal Article
Open access
AHAdrian Hartert
Adrian Hartert
BBBenedikt Böhm
Benedikt Böhm
MHManuel Hegelheimer
Manuel Hegelheimer
STSimon Thiele
Simon Thiele
AFAnna T.S. Freiberg
Anna T.S. Freiberg
Traditional alkaline water electrolysis (AWE) is an established technology for green hydrogen production but suffers from high overpotentials and balance of plant costs. Efforts to allow high current densities have included a zero-gap design but so far neglected the parallel advancements in related membrane electrolysis technologies. This study therefore employs a 5 cm2 zero-gap AWE setup with a porous diaphragm, nanostructured electrodes, and mild electrolyte concentrations of 1 M KOH. Initially, the system is bound to low current densities by mass transport limitation. By variation of the compression and comparison of different porous transport layers (PTLs), a structure–performance relationship is developed. The gas purity and attained hydrogen flux at the cathode are analyzed simultaneously. Configurations with low overpotentials are identified to commonly bear high crossover rates so that optimization toward efficient hydrogen production can be achieved only when electrochemical and gas crossover analyses are paired. A potential solution is found when the path of the liquid electrolyte within the cell is modified. By forcing convective transport through the PTL, the gas bubbles are removed efficiently. Ultimately, the system is able to reach current densities above 2.5 A cm–2 at 2.3 V while keeping adequate gas purity.

3 December 2024 in Chemical Communications
Verified
Journal Article
Open access
PDF file
LHLinus Hager
Linus Hager
MSMaximilian Schrodt
Maximilian Schrodt
MHManuel Hegelheimer
Manuel Hegelheimer
JSJulian Stonawski
Julian Stonawski
PLPradipkumar Leuaa
Pradipkumar Leuaa
Jochen KerresJochen Kerres
Jochen Kerres
The study of cationic groups in novel anion exchange membranes suggests an approach to reducing H 2 crossover and improving performance.

22 November 2024 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
AFAnna T.S. Freiberg
Anna T.S. Freiberg
MHManuel Hegelheimer
Manuel Hegelheimer
STSimon Thiele
Simon Thiele
PEM water electrolyzers (PEMWEs) are able to store fluctuating renewable energy as chemical energy in the form of hydrogen gas. Due to the low pH and high anode potentials, however, only scarce iridium-based catalysts are considered to be reasonably stable to be employed commercially. This significant drawback for large scale application encourages research into AEM water electrolyzers (AEMWEs). They are ought to combine the advantages of polymer electrolyte based water electrolysis technologies with operation at elevated pH that allows usage of non-PGM based OER catalysts.1 Though the overall cell reaction is the same whether run in acidic or alkaline environment, the water-splitting electrode switches from the anode to the cathode, which necessarily changes the direction of osmotic drag within the polymer electrolyte. Additionally, AEM cells are commonly operated in a liquid-liquid set-up where both sides are actively flushed with an alkaline electrolyte solution, which further complicates the understanding of interfacial effects, product formation and removal as well as limiting factors for the overall electrical efficiency (i.e., overpotential contributions) of the system. With AEMWE research still being at an infant state compared to PEMWE it is important to learn as much as possible form the established system to boost the understanding and therewith performance and lifetime of the new technology. Especially gas crossover has been identified as a significant driver for PEMWE degradation2-3 and is limiting the operating range due to the formation of explosive mixtures at the anode. Also, the faradaic efficiency loss stemming from gas crossover should not be neglected. With the extent of gas crossover being strongly dependent on a multitude of experimental parameters, it is difficult to quantitatively compare data from different research groups. In this study we show a 1:1 comparison of AEMWE and PEMWE single cell measurements with special focus on the gas crossover characteristics and the concurrent faradaic efficiency achieved for both technologies. We fixed the experimental parameters to be as close as possible (PTL structure, flow field design, compression etc.) in order for this in-house comparison to serve as a basis for a better understanding of crossover phenomena both in AEMWE and PEMWE cells. By thoroughly analyzing similarities and differences regarding crossover dependency on the operating range the most important mechanisms and therewith influencing factors for both technologies are discussed. Miller, H. A.; Bouzek, K.; Hnat, J.; Loos, S.; Bernäcker, C. I.; Weißgärber, T.; Röntzsch, L.; Meier-Haack, J., Green hydrogen from anion exchange membrane water electrolysis: a review of recent developments in critical materials and operating conditions. Sustainable Energy & Fuels 2020, 4, 2114-2133. Kuhnert, E.; Heidinger, M.; Sandu, D.; Hacker, V.; Bodner, M., Analysis of PEM Water Electrolyzer Failure Due to Induced Hydrogen Crossover in Catalyst-Coated PFSA Membranes. Membranes (Basel) 2023, 13. Weiß, A.; Siebel, A.; Bernt, M.; Shen, T. H.; Tileli, V.; Gasteiger, H. A., Impact of Intermittent Operation on Lifetime and Performance of a PEM Water Electrolyzer. J. Electrochem. Soc. 2019, 166, F487-F497.