27 December 2023 in IEEE Transactions on Applied Superconductivity
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
26 April 2022 in IEEE Transactions on Applied Superconductivity
During the integrated commissioning of JT-60SA tokamak, the Toroidal Field (TF) magnet has experienced fast current discharges which have induced AC losses in its winding packs (WP) and in its casings. Using the thermo-hydraulic sensors network installed at the inlet and outlet of the TF coils, we have performed enthalpy balances to estimate the transient heat loads generated by AC losses. In parallel, we have modeled the hysteresis and coupling losses produced in the WP and the eddy currents losses produced in the casings by such events. We then assess and discuss the consistency between these experimental and first theoretical analyses from the energy balance point of view.
10 January 2019 in Fusion Engineering and Design
13 February 2025 in IEEE Transactions on Applied Superconductivity
The JT-60SA project succeeded in commissioning test toward the first plasma in 2023 under a framework: the Satellite Tokamak Programme of the Broader Approach Agreement between EU and Japan (H. Shirai et al., 2016). JT-60SA is a tokamak type magnetic confinement device with a superconducting magnet system (Y. Koide et al., 2015) developed and operated at the Quantum Science and Technology institute (QST) in Japan. The magnet system consists of 18 Toroidal Field coils, 6 Equilibrium Field coils, and 4 modules of Central Solenoids, and all the coils are superconducting magnets. In the first commissioning, during 2020 - 2021, JT-60SA has experienced a discharge incident at the EF1 magnet (H. Shirai et al., 2024). As a conclusion of the investigation of the incident, it turned out that the insulation resistance of the magnet system was insufficient. Although the insulation was partly reinforced, the voltage holding under accidentally arising Paschen conditions was not improved enough for the recent operation (OP-1, 2023) (K. Hamada et al., 2024). To prevent the magnet system from discharging during vacuum degradation, a vacuum monitoring system must be prepared to detect vacuum degradation and ramp down the magnet current immediately in case of unexpected vacuum degradation. In this article, the development of the vacuum monitoring system, operational results, and the future plan of the system will be described.
2 March 2021 in IEEE Transactions on Applied Superconductivity
The JT-60SA central solenoid (CS), which consists of four stacked modules, is cooled to an operating temperature of 4.5 K by supercritical helium (SHe). During cool-down from room temperature to 4.5 K, in order to avoid a damage on the coil, it is required to reduce thermal stress due to temperature difference in the coil. In the cool-down operation, the CS needs to control the maximum temperature difference in the longitudinal direction of the cable-in-conduit (CIC) conductor below 40 K. However, since that could damage the coil, correctly estimating the temperature distribution in the conductor is important for ensuring the cool-down operation is performed safely. In the present study, the JT-60SA CS module was prepared and the inlet and outlet temperatures, as well as the SHe mass flow rate, were measured until the CS module was cooled to operating temperature, after which a CS module simulation was performed in order to determine the effect of the inlet temperature on the cool-down speed. From the simulation results, it was concluded that the average cool-down speed was 0.73 K/h and the CS module reached 80 K in approximately 8.3 days while maintaining the maximum temperature difference within 40 K. Furthermore, the temperature difference between the inlet and outlet was kept within 25 K in order to limit the thermal stress. Taken together, the results of our analyses provide fundamental data that can be used to evaluate the safe cool-down operation of the coil and thus protect the coil systems.
23 March 2022 in IEEE Transactions on Applied Superconductivity
The full-supercond ucting tokamak JT-60 Super Advanced (JT-60SA) has been constructed under the JA-EU Broader Approach agreement (Fukui et al. , 2019). The construction was completed in March 2020 followed by the first cool down operation. The magnet system used in JT-60SA consists of 18 toroidal field (TF) coils, 6 equilibrium field (EF) coils and 4 modules of central solenoid (CS) (Fukui et al. , 2020). All magnets are cooled by a forced flow of helium (Hoa et al. , 2012). During cool down uniform magnet temperatures are necessary. However, helium flow is difficult to be distributed accurately for each magnet, because the flow characteristics of each magnet are different. The objective of this work is to investigate the flow characteristics of all magnets in preparation for the next cool down operation.