23 January 2010 in Journal of Magnetic Resonance Imaging
Purpose: To improve spatial and temporal resolution and signal‐to‐noise ratio (SNR) in three‐dimensional (3D) radial contrast‐enhanced (CE) time‐resolved MR angiography by means of a novel hybrid phase contrast (PC) and CE MRA acquisition and HYPR reconstruction (PC HYPR Flow). Materials and Methods: PC HYPR Flow consists of a CE exam immediately followed by a PC scan used to constrain the HYPR reconstruction of the time series. Temporal resolution of the new method was studied in computer simulations. The feasibility of the new technique was studied in healthy subjects and patients with brain arteriovenous malformations and in a canine model of aneurysms. Results: Simulations demonstrated preservation of contrast agent dynamics in proximal vessels, showing better performance than peer methods for acceleration up to 20 in 2D. In vivo, PC HYPR Flow yielded 3D time series with frame rate of 0.5 s and significantly outperformed two peer methods by means of a major increase in spatial resolution (0.8 × 0.8 × 0.8 mm3) and arterial/venous ratio, while maintaining necessary temporal waveform fidelity and high SNR. Conclusion: This initial study indicates that PC HYPR Flow simultaneously provides 3D isotropic sub‐millimeter spatial resolution, sub‐second temporal reconstruction windows and high SNR level, which may benefit a wide range of CE MRA applications. J. Magn. Reson. Imaging 2010; 31: 447–456.
27 October 2016 in Magnetic Resonance in Medicine
Purpose To advance the best solutions to two important RF pulse design problems with an open head‐to‐head competition. Methods Two sub‐challenges were formulated in which contestants competed to design the shortest simultaneous multislice (SMS) refocusing pulses and slice‐selective parallel transmission (pTx) excitation pulses, subject to realistic hardware and safety constraints. Short refocusing pulses are needed for spin echo SMS imaging at high multiband factors, and short slice‐selective pTx pulses are needed for multislice imaging in ultra‐high field MRI. Each sub‐challenge comprised two phases, in which the first phase posed problems with a low barrier of entry, and the second phase encouraged solutions that performed well in general. The Challenge ran from October 2015 to May 2016. Results The pTx Challenge winners developed a spokes pulse design method that combined variable‐rate selective excitation with an efficient method to enforce SAR constraints, which achieved 10.6 times shorter pulse durations than conventional approaches. The SMS Challenge winners developed a time‐optimal control multiband pulse design algorithm that achieved 5.1 times shorter pulse durations than conventional approaches. Conclusion The Challenge led to rapid step improvements in solutions to significant problems in RF excitation for SMS imaging and ultra‐high field MRI. Magn Reson Med 78:1352–1361, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
21 November 2022 in Magnetic Resonance in Medicine
Purpose: To validate QSM‐based biomagnetic liver susceptometry (BLS) to measure liver iron overload at 1.5 T and 3.0 T using superconducting quantum interference devices (SQUID)‐based BLS as reference.Methods: Subjects with known or suspected iron overload were recruited for QSM‐BLS at 1.5 T and 3.0 T using eight different protocols. SQUID‐BLS was also obtained in each subject to provide susceptibility reference. A recent QSM method based on data‐adaptive regularization was used to obtain susceptibility and maps. Measurements of susceptibility and were obtained in the right liver lobe. Linear mixed‐effects analysis was used to estimate the contribution of specific acquisition parameters to QSM‐BLS. Linear regression and Bland–Altman analyses were used to assess the relationship between QSM‐BLS and SQUID‐BLS/.Results: Susceptibility maps showed high subjective quality for each acquisition protocol across different iron levels. High linear correlation was observed between QSM‐BLS and SQUID‐BLS at 1.5 T (r2 range, [0.82, 0.84]) and 3.0 T (r2 range, [0.77, 0.85]) across different acquisition protocols. QSM‐BLS and were highly correlated at both field strengths (r2 range at 1.5 T, [0.94, 0.99]; 3.0 T, [0.93, 0.99]). High correlation (r2 = 0.99) between 1.5 T and 3.0 T QSM‐BLS, with narrow reproducibility coefficients (range, [0.13, 0.21] ppm) were observed for each protocol.Conclusion: This work evaluated the feasibility and performance of liver QSM‐BLS across iron levels and acquisition protocols at 1.5 T and 3.0 T. High correlation and reproducibility were observed between QSM‐BLS and SQUID‐BLS across protocols and field strengths. In summary, QSM‐BLS may enable reliable and reproducible quantification of liver iron concentration.
5 October 2022 in Magnetic Resonance in Medicine
Purpose: To improve image quality and resolution of dynamic susceptibility contrast perfusion weighted imaging (DSC‐PWI) by developing acquisition and reconstruction methods exploiting the temporal regularity property of DSC‐PWI signal.Theory and Methods: A novel regularized reconstruction is proposed that recovers DSC‐PWI series from interleaved segmented spiralk‐space acquisition using higher order temporal smoothness (HOTS) properties of the DSC‐PWI signal. The HOTS regularization is designed to tackle representational insufficiency of the standard first‐order temporal regularizations for supporting higher accelerations. The higher accelerations allow fork‐space coverage with shorter spiral interleaves resulting in improved acquisition point spread function, and acquisition of images at multiple TEs for more accurate DSC‐PWI analysis.Results: The methods were evaluated in simulated and in‐vivo studies. HOTS regularization provided increasingly more accurate models for DSC‐PWI than the standard first‐order methods with either quadratic or robust norms at the expense of increased noise. HOTS DSC‐PWI optimized for noise and accuracy demonstrated significant advantages over both spiral DSC‐PWI without temporal regularization and traditional echo‐planar DSC‐PWI, improving resolution and mitigating image artifacts associated with long readout, including blurring and geometric distortions. In context of multi‐echo DSC‐PWI, the novel methods allowed ∼4.3× decrease of voxel volume, providing 2× number of TEs compared to the previously published results.Conclusions: Proposed HOTS reconstruction combined with dynamic spiral sampling represents a valid mechanism for improving image quality and resolution of DSC‐PWI significantly beyond those available with established fast imaging techniques.
17 March 2023 in Magnetic Resonance in Medicine
Purpose: To improve repeatability and reproducibility across acquisition parameters and reduce bias in quantitative susceptibility mapping (QSM) of the liver, through development of an optimized regularized reconstruction algorithm for abdominal QSM.Methods: An optimized approach to estimation of magnetic susceptibility distribution is formulated as a constrained reconstruction problem that incorporates estimates of the input data reliability and anatomical priors available from chemical shift‐encoded imaging. The proposed data‐adaptive method was evaluated with respect to bias, repeatability, and reproducibility in a patient population with a wide range of liver iron concentration (LIC). The proposed method was compared to the previously proposed and validated approach in liver QSM for two multi‐echo spoiled gradient‐recalled echo protocols with different acquisition parameters at 3T. Linear regression was used for evaluation of QSM methods against a reference FDA‐approved ‐based LIC measure and measurements; repeatability/reproducibility were assessed by Bland–Altman analysis.Results: The data‐adaptive method produced susceptibility maps with higher subjective quality due to reduced shading artifacts. For both acquisition protocols, higher linear correlation with both ‐ and ‐based measurements were observed for the data‐adaptive method ( for , for ) than the standard method ( and ). For both protocols, the data‐adaptive method enabled better test–retest repeatability (repeatability coefficients 0.19/0.30 ppm for the data‐adaptive method, 0.38/0.47 ppm for the standard method) and reproducibility across protocols (reproducibility coefficient 0.28 vs. 0.53ppm) than the standard method.Conclusions: The proposed data‐adaptive QSM algorithm may enable quantification of LIC with improved repeatability/reproducibility across different acquisition parameters as 3T.