Collin J. Buelo

Collin J. Buelo

Auto-generated profile, based on publicly available information

Collin J. Buelo

GE Healthcare Waukesha Wisconsin USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
RGRuiqi Geng
Ruiqi Geng
CBCollin J. Buelo
Collin J. Buelo
MSMahalakshmi Sundaresan
Mahalakshmi Sundaresan
JSJitka Starekova
Jitka Starekova
NPNikolaos Panagiotopoulos
Nikolaos Panagiotopoulos
DHDiego Hernando
Diego Hernando
Background: There is an unmet need for fully automated image prescription of the liver to enable efficient, reproducible MRI.Purpose: To develop and evaluate artificial intelligence (AI)‐based liver image prescription.Study Type: Prospective.Population: A total of 570 female/469 male patients (age: 56 ± 17 years) with 72%/8%/20% assigned randomly for training/validation/testing; two female/four male healthy volunteers (age: 31 ± 6 years).Field Strength/Sequence: 1.5 T, 3.0 T; spin echo, gradient echo, bSSFP.Assessment: A total of 1039 three‐plane localizer acquisitions (26,929 slices) from consecutive clinical liver MRI examinations were retrieved retrospectively and annotated by six radiologists. The localizer images and manual annotations were used to train an object‐detection convolutional neural network (YOLOv3) to detect multiple object classes (liver, torso, and arms) across localizer image orientations and to output corresponding 2D bounding boxes. Whole‐liver image prescription in standard orientations was obtained based on these bounding boxes. 2D detection performance was evaluated on test datasets by calculating intersection over union (IoU) between manual and automated labeling. 3D prescription accuracy was calculated by measuring the boundary mismatch in each dimension and percentage of manual volume covered by AI prescription. The automated prescription was implemented on a 3 T MR system and evaluated prospectively on healthy volunteers.Statistical Tests: Paired t‐tests (threshold = 0.05) were conducted to evaluate significance of performance difference between trained networks.Results: In 208 testing datasets, the proposed method with full network had excellent agreement with manual annotations, with median IoU > 0.91 (interquartile range < 0.09) across all seven classes. The automated 3D prescription was accurate, with shifts <2.3 cm in superior/inferior dimension for 3D axial prescription for 99.5% of test datasets, comparable to radiologists' interreader reproducibility. The full network had significantly superior performance than the tiny network for 3D axial prescription in patients. Automated prescription performed well across single‐shot fast spin‐echo, gradient‐echo, and balanced steady‐state free‐precession sequences in the prospective study.Data Conclusion: AI‐based automated liver image prescription demonstrated promising performance across the patients, pathologies, and field strengths studied.Evidence Level: 4.Technical Efficacy: Stage 1.

2 September 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JTJiayi Tang
Jiayi Tang
DTDaiki Tamada
Daiki Tamada
RSRaphael Do Vale Souza
Raphael Do Vale Souza
AFAaron Faacks
Aaron Faacks
JSJitka Starekova
Jitka Starekova
DHDiego Hernando
Diego Hernando
Purpose: To implement, optimize, and validate parallel imaging (PI)‐accelerated, 2D, flip angle modulated (FAM) chemical shift‐encoded quantification of liver proton‐density fat fraction (PDFF), with motion insensitivity. Methods: The optimization cost function that determines flip angles in FAM was generalized for PI. Phantom studies and prospective studies in volunteers with varying liver fat levels were performed. Free‐breathing FAM was acquired in the axial, sagittal, and coronal planes, with varying nominal PI acceleration factors ( R ) of 1.0 to 3.0. A breath‐held, commercially available 3D chemical shift‐encoded method was acquired as reference for PDFF. Overall image quality, qualitative SNR, and motion artifacts for all methods were Likert‐scale rated. PDFF measured by FAM was compared to reference to assess bias. Test–retest repeatability was assessed for all methods by repeating acquisitions after volunteer repositioning. Noise performance was assessed with standard deviation of PDFF maps as R increased. Results: The reader study ( N = 3 readers/10 subjects) demonstrated excellent image quality for FAM during free‐breathing, with reduced motion artifacts compared to breath‐held reference ( p < 0.01). PI‐accelerated FAM shows fewer motion artifacts than unaccelerated FAM ( p < 0.01). In all planes and accelerations, PDFF measured by FAM showed good agreement with reference PDFF measurements (mean bias: −0.4% to 2.0% PDFF; 95% limits of agreement: 2.8% to 4.0% PDFF). FAM in axial and coronal planes showed similar or improved repeatability (repeatability coefficient = 1.7% to 2.6% PDFF) compared to the reference (2.7%). Sagittal FAM shows similar or worse repeatability (repeatability coefficient = 3.0% to 3.6%). FAM with R = 2.0 has good noise performance and high SNR efficiency. Conclusion: FAM, in axial or coronal planes with R = 2.0, is optimal for motion‐insensitive liver PDFF quantification.

17 March 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JVJulia V. Velikina
Julia V. Velikina
RZRuiyang Zhao
Ruiyang Zhao
CBCollin J. Buelo
Collin J. Buelo
ASAlexey A. Samsonov
Alexey A. Samsonov
SRScott B. Reeder
Scott B. Reeder
DHDiego Hernando
Diego Hernando
Purpose: To improve repeatability and reproducibility across acquisition parameters and reduce bias in quantitative susceptibility mapping (QSM) of the liver, through development of an optimized regularized reconstruction algorithm for abdominal QSM.Methods: An optimized approach to estimation of magnetic susceptibility distribution is formulated as a constrained reconstruction problem that incorporates estimates of the input data reliability and anatomical priors available from chemical shift‐encoded imaging. The proposed data‐adaptive method was evaluated with respect to bias, repeatability, and reproducibility in a patient population with a wide range of liver iron concentration (LIC). The proposed method was compared to the previously proposed and validated approach in liver QSM for two multi‐echo spoiled gradient‐recalled echo protocols with different acquisition parameters at 3T. Linear regression was used for evaluation of QSM methods against a reference FDA‐approved ‐based LIC measure and measurements; repeatability/reproducibility were assessed by Bland–Altman analysis.Results: The data‐adaptive method produced susceptibility maps with higher subjective quality due to reduced shading artifacts. For both acquisition protocols, higher linear correlation with both ‐ and ‐based measurements were observed for the data‐adaptive method ( for , for ) than the standard method ( and ). For both protocols, the data‐adaptive method enabled better test–retest repeatability (repeatability coefficients 0.19/0.30 ppm for the data‐adaptive method, 0.38/0.47 ppm for the standard method) and reproducibility across protocols (reproducibility coefficient 0.28 vs. 0.53ppm) than the standard method.Conclusions: The proposed data‐adaptive QSM algorithm may enable quantification of LIC with improved repeatability/reproducibility across different acquisition parameters as 3T.

5 September 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
CBCollin J. Buelo
Collin J. Buelo
JVJulia Velikina
Julia Velikina
LMLu Mao
Lu Mao
RZRuiyang Zhao
Ruiyang Zhao
QYQing Yuan
Qing Yuan
DHDiego Hernando
Diego Hernando
Purpose: To evaluate the repeatability and reproducibility of QSM of the liver via single breath‐hold chemical shift–encoded MRI at both 1.5 T and 3 T in a multicenter, multivendor study in subjects with iron overload.Methods: This prospective study included four academic medical centers with three different MRI vendors at 1.5 T and 3 T. Subjects with known or suspected liver iron overload underwent multi‐echo spoiled gradient‐recalled‐echo scans at each field strength. A subset received repeatability testing at either 1.5 T or 3 T. Susceptibility and maps were reconstructed from the multi‐echo images and analyzed at a single center. QSM‐measured susceptibility was compared with and a commercial R2‐based liver iron concentration method across centers and field strengths using linear regression and F‐tests on the intercept and slope. Field‐strength reproducibility and test/retest repeatability were evaluated using Bland–Altman analysis.Results: A total of 155/80 data sets (test/retest) were available at 1.5 T, and 159/70 data sets (test/retest) were available at 3 T. Calibrations across sites were reproducible, with some variability (e.g., susceptibility slope with liver iron concentration ranged from 0.102 to 0.123 g/[mgppm] across centers at 1.5 T). Field strength reproducibility was good (concordance correlation coefficient = 0.862), and test/retest repeatability was excellent (intraclass correlation coefficient = 0.951).Conclusion: QSM as an imaging biomarker of liver iron overload is feasible and repeatable across centers and MR vendors. It may be complementary with as they are obtained from the same acquisition. Although good reproducibility was observed, liver QSM may benefit from standardization of acquisition parameters. Overall, QSM is a promising method for liver iron quantification.

9 July 2026 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
GFGarrett C. Fullerton
Garrett C. Fullerton
JTJiayi Tang
Jiayi Tang
JSJitka Starekova
Jitka Starekova
JHJulius Frederik Heidenreich
Julius Frederik Heidenreich
APAli Pirasteh
Ali Pirasteh
SRScott B. Reeder
Scott B. Reeder
Background: Access to MRI is limited by lengthy exam times and inefficient utilization. Focused protocols can reduce exam times, but workflow variability and inefficient room turnaround contribute to conservative scheduling with long exam slots. Purpose: To develop and evaluate a high‐throughput clinical MRI suite architecture and workflow, using an AI‐prescribed free‐breathing chemical shift‐encoded (CSE) MRI exam to quantify liver proton density fat fraction (PDFF) in under 5 min of total MRI room time. Study Type: Prospective. Subjects: 24 healthy volunteers in two cohorts: 12 research staff (7 women/5 men; age 26.8 ± 5.8 years) and 12 community volunteers (6 women/6 men; age 41.3 ± 13.5 years). Field Strength/Sequence: 1.5 T; free‐breathing 2D multi‐echo gradient echo CSE‐MRI. Assessment: Each participant underwent three nonconsecutive CSE‐MRI exams in a continuously queued workflow to characterize timing and PDFF repeatability. Workflow intervals were recorded from timestamped video review and image metadata. Staff cohort exams included two CSE‐MRI acquisitions to assess within‐exam repeatability, while community cohort exams included one to simulate clinical practice. Three radiologists (8/13/14 years of experience) independently evaluated AI‐automated prescriptions for complete liver coverage and rated CSE‐MRI image quality (five‐point Likert scale). Statistical Tests: Student's t ‐tests; Gwet's AC2; repeatability coefficients (RCs) with bootstrap 95% confidence intervals; Bland–Altman analysis. p < 0.05 was significant. Results: Diagnostic image quality was achieved in all 72 exams (median PDFF Likert score 5/5, inter‐rater AC2 ≥ 0.86). Total MRI room times averaged 4:09 ± 0:14 min (staff) and 3:35 ± 0:34 min (community). Turnaround times averaged under 2 min, enabling throughput of 16.1 exams per hour in the community cohort. Automated prescription achieved complete liver coverage in all exams. PDFF RCs were 0.78% (staff within‐exam), 0.99% (staff between‐exam), and 1.21% (community between‐exam) absolute PDFF. Data Conclusion: The proposed high‐throughput MRI workflow achieved over 16 exams per hour with highly repeatable liver fat quantification, demonstrating a framework for improving MRI utilization and access. Evidence Level: 1. Stage of Technical Efficacy: 2.

2 October 2026 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
GFGarrett C. Fullerton
Garrett C. Fullerton
JSJitka Starekova
Jitka Starekova
CBCollin J. Buelo
Collin J. Buelo
DHDavid T. Harris
David T. Harris
RSRaphael Do Vale Souza
Raphael Do Vale Souza
DHDiego Hernando
Diego Hernando
Background: Manual prescription of liver MRI volumes introduces inter‐operator variability and prolongs exam duration. Artificial intelligence (AI)‐based prescription has been demonstrated, but existing work has been limited to single‐vendor settings. Purpose: To develop and validate an AI model for automated liver MRI prescription using a large, consecutive, multicenter dataset encompassing multiple vendors, field strengths, localizer sequences, and liver pathologies. Study Type: Retrospective. Population: A total of 11,012 patients (5928 female) who underwent liver MRI exams across three vendors (GE HealthCare, Philips Healthcare, Siemens Healthineers) at three institutions, split into training/validation/test sets (70/10/20%). Liver disorders included cirrhosis, ascites, portal hypertension, and iron overload. Field Strength/Sequence: Three‐plane localizers acquired using single‐shot fast spin echo (68.3%) and gradient echo (31.7%) at 1.5 T (52.8%) and 3 T (47.2%). Assessment: A YOLOv8 object detection model was trained to detect the liver, torso, and arms on localizer images. Automated prescription accuracy was assessed using three‐dimensional intersection‐over‐union (IoU 3D ) for axial, coronal, and sagittal prescriptions. Subgroup analyses evaluated performance across technical and patient‐related factors. Statistical Tests: Mann–Whitney U tests with Bonferroni correction, Kruskal‐Wallis tests, Wilcoxon signed‐rank tests, Spearman correlation. Effect sizes were calculated using rank‐biserial correlation ( r rb ) and epsilon‐squared ( ε 2 ). p < 0.05 was considered statistically significant. Results: Median axial prescription IoU 3D was 0.963 (interquartile range: 0.946–0.976), with median IoU 3D above 0.940 for coronal and sagittal prescriptions. For axial prescriptions, margins less than 4 mm in each direction were required to achieve complete coverage of manual prescriptions in 90% of cases in the held‐out test set. Effects were negligible to small across vendors, field strengths, localizer sequences, and patient factors ( r rb ≤ 0.16, ε 2 ≤ 0.01). Data Conclusion: A single multivendor model achieved accurate automated liver MRI prescription without clinically meaningful performance differences across vendors, field strengths, localizer sequences, or patient factors. Evidence Level: 2. Technical Efficacy: Stage 1.