Julianna M. Richie

Julianna M. Richie

Auto-generated profile, based on publicly available information

Julianna M. Richie

Department of Biomedical Engineering, University of Michigan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2023 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PPParas R Patel
Paras R Patel
EWElissa J Welle
Elissa J Welle
JLJoseph G Letner
Joseph G Letner
HSHao Shen
Hao Shen
ABAutumn J Bullard
Autumn J Bullard
CCCindy Chestek
Cindy Chestek
Objective. The Utah array is widely used in both clinical studies and neuroscience. It has a strong track record of safety. However, it is also known that implanted electrodes promote the formation of scar tissue in the immediate vicinity of the electrodes, which may negatively impact the ability to record neural waveforms. This scarring response has been primarily studied in rodents, which may have a very different response than primate brain. Approach. Here, we present a rare nonhuman primate histological dataset (n = 1 rhesus macaque) obtained 848 and 590 d after implantation in two brain hemispheres. For 2 of 4 arrays that remained within the cortex, NeuN was used to stain for neuron somata at three different depths along the shanks. Images were filtered and denoised, with neurons then counted in the vicinity of the arrays as well as a nearby section of control tissue. Additionally, 3 of 4 arrays were imaged with a scanning electrode microscope to evaluate any materials damage that might be present. Main results. Overall, we found a 63% percent reduction in the number of neurons surrounding the electrode shanks compared to control areas. In terms of materials, the arrays remained largely intact with metal and Parylene C present, though tip breakage and cracks were observed on many electrodes. Significance. Overall, these results suggest that the tissue response in the nonhuman primate brain shows similar neuron loss to previous studies using rodents. Electrode improvements, for example using smaller or softer probes, may therefore substantially improve the tissue response and potentially improve the neuronal recording yield in primate cortex.

1 December 2021 in Journal of Neural Engineering
Verified
Journal Article
Open access
YHYu Huan
Yu Huan
JGJeffrey P Gill
Jeffrey P Gill
JFJohanna B Fritzinger
Johanna B Fritzinger
PPParas R Patel
Paras R Patel
JRJulianna M Richie
Julianna M Richie
HCHillel J Chiel
Hillel J Chiel
Objective. To understand neural circuit dynamics, it is critical to manipulate and record many individual neurons. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems. Carbon fiber electrodes (CFEs) are 8 µm-diameter electrodes that can be assembled into dense arrays (pitches ⩾ 80 µm). They have good signal-to-noise ratios (SNRs) and provide stable extracellular recordings both acutely and chronically in neural tissue in vivo (e.g. rat motor cortex). The small fiber size suggests that arrays could be used for intracellular stimulation. Approach. We tested CFEs for intracellular stimulation using the large identified and electrically compact neurons of the marine mollusk Aplysia californica. Neuron cell bodies in Aplysia range from 30 µm to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. Main results. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular, as shown by simultaneous glass microelectrode recordings. CFEs coated with platinum-iridium could stimulate and had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. CFEs were less sensitive to mechanical perturbations than glass microelectrodes. Significance. The ability to do stable multi-channel recording while stimulating and recording intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.

8 June 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
EWElissa J. Welle
Elissa J. Welle
JWJoshua E. Woods
Joshua E. Woods
AJAhmad A. Jiman
Ahmad A. Jiman
JRJulianna M. Richie
Julianna M. Richie
EBElizabeth C. Bottorff
Elizabeth C. Bottorff
CCCynthia A. Chestek
Cynthia A. Chestek
Bioelectric medicine treatments target disorders of the nervous system unresponsive to pharmacological methods. While current stimulation paradigms effectively treat many disorders, the underlying mechanisms are relatively unknown, and current neuroscience recording electrodes are often limited in their specificity to gross averages across many neurons or axons. Here, we develop a novel, durable carbon fiber electrode array adaptable to many neural structures for precise neural recording. Carbon fibers ( 6.8 μm diameter) were sharpened using a reproducible blowtorch method that uses the reflection of fibers against the surface of a water bath. The arrays were developed by partially embedding carbon fibers in medical-grade silicone to improve durability. We recorded acute spontaneous electrophysiology from the rat cervical vagus nerve (CVN), feline dorsal root ganglia (DRG), and rat brain. Blowtorching resulted in fibers of 72.3 ± 33.5-degree tip angle with 146.8 ± 17.7 μm exposed carbon. Observable neural clusters were recorded using sharpened carbon fiber electrodes from rat CVN ( 41.8 μV pp ), feline DRG ( 101.1 μV pp ), and rat brain ( 80.7 μV pp ). Recordings from the feline DRG included physiologically relevant signals from increased bladder pressure and cutaneous brushing. These results suggest that this carbon fiber array is a uniquely durable and adaptable neural recording device. In the future, this device may be useful as a bioelectric medicine tool for diagnosis and closed-loop neural control of therapeutic treatments and monitoring systems.

30 January 2024 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JLJungho Lee
Jungho Lee
JLJoseph G. Letner
Joseph G. Letner
JLJongyup Lim
Jongyup Lim
GAGabriele Atzeni
Gabriele Atzeni
JLJiawei Liao
Jiawei Liao
DBDavid Blaauw
David Blaauw
This article proposes StiMote, an untethered, free-floating and individually addressable stimulator mote designed for visual cortex stimulation, aimed at vision restoration. The system is optically powered by a custom photovoltaic (PV) layer. In addition, the photodiode (PD) layer captures the light modulation and forwards it to the optical receiver (ORX) including a tranimpedance amplifier. Translated instructions can assign a unique slot, up to 1024 available, to each mote within the time-division multiple access (TDMA) framework. In this work, we propose an automatic charge balance (CB) technique that monitors the injected charge to balance in bi-phasic switched-capacitor stimulation (SCS). The chip was confirmed fully functional when operated completely wirelessly using harvested light. Measurement results revealed a power consumption of 4.48 $\mu$ W with a 7.5-kb/s optical downlink data rate, corresponding to continuous updates at 2.5 Hz of 1024 motes to their individual 3-b stimulation intensity levels. The dc–dc converter, responsible for providing high voltage for stimulation, demonstrated 4.3-V output voltage when unloaded, with a maximum efficiency of 67.4%. The proposed CB circuit exhibited linear controllability of stimulation charge up to 16 nC, with a charge imbalance of less than 0.2 nC. Furthermore, in vitro testing confirmed the absence of chemical reactions at electrodes, and in vivo experiments conducted on live rats verified the effectiveness of the stimulation through StiMote.

31 January 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
JRJulianna Richie
Julianna Richie
JLJoseph G. Letner
Joseph G. Letner
Autumn McLane-SvobodaAutumn McLane-Svoboda
Autumn McLane-Svoboda
YHYu Huan
Yu Huan
DGDorsa Haji Ghaffari
Dorsa Haji Ghaffari
CCCindy Chestek
Cindy Chestek
Multielectrode arrays for interfacing with neurons are of great interest for a wide range of medical applications. However, current electrodes cause damage over time. Ultra small carbon fibers help to address issues but controlling the electrode site geometry is difficult. Here we propose a methodology to create small, pointed fiber electrodes (SPFe). We compare the SPFe to previously made blowtorched fibers in characterization. The SPFe result in small site sizes $(105.4 \pm 20.8~\mu \text{m}^{{2}})$ with consistently sharp points (20.8 ± 7.64°). Additionally, these electrodes were able to record and/or stimulate neurons multiple animal models including rat cortex, mouse retina, Aplysia ganglia and octopus axial cord. In rat cortex, these electrodes recorded significantly higher peak amplitudes than the traditional blowtorched fibers. These SPFe may be applicable to a wide range of applications requiring a highly specific interface with individual neurons.

15 May 2023 in Journal of Neural Engineering
Verified
Journal Article
Closed access
TDTianshu Dong
Tianshu Dong
Lei ChenLei Chen
Lei Chen
PPParas R Patel
Paras R Patel
JRJulianna M Richie
Julianna M Richie
CCCindy Chestek
Cindy Chestek
ASAlbert J Shih
Albert J Shih
Objective. Carbon fiber (CF) is good for chronic neural recording due to the small diameter (7 µm), high Young’s modulus, and low electrical resistance, but most high-density carbon fiber (HDCF) arrays are manually assembled with labor-intensive procedures and limited by the accuracy and repeatability of the operator handling. A machine to automate the assembly is desired. Approach. The HDCF array assembly machine contains: (1) a roller-based CF extruder, (2) a motion system with three linear and one rotary stages, (3) an imaging system with two digital microscope cameras, and (4) a laser cutter. The roller-based extruder automatically feeds single CF as raw material. The motion system aligns the CF with the array backend then places it. The imaging system observes the relative position between the CF and the backend. The laser cutter cuts off the CF. Two image processing algorithms are implemented to align the CF with the support shanks and circuit connection pads. Main results. The machine was capable of precisely handling 6.8 μm carbon fiber electrodes (CFEs). Each electrode was placed into a 12 μm wide trenches in a silicon support shank. Two HDCF arrays with 16 CFEs populated on 3 mm shanks (with 80 μm pitch) were fully assembled. Impedance measurements were found to be in good agreement with manual assembled arrays. One HDCF array was implanted in the motor cortex in an anesthetized rat and was able to detect single unit activity. Significance. This machine can eliminate the manual labor-intensive handling, alignment and placement of single CF during assembly, providing a proof-of-concepts towards fully automated HDCF array assembly and batch production.