Studies of cortical function in the awake infant are extremely challenging to undertake with traditional neuroimaging approaches. Partly in response to this challenge, functional near-infrared spectroscopy (fNIRS) has become increasingly common in developmental neuroscience, but has significant limitations including resolution, spatial specificity and ergonomics. In adults, high-density arrays of near-infrared sources and detectors have recently been shown to yield dramatic improvements in spatial resolution and specificity when compared to typical fNIRS approaches. However, most existing fNIRS devices only permit the acquisition of ~20-100 sparsely distributed fNIRS channels, and increasing the number of optodes presents significant mechanical challenges, particularly for infant applications. A new generation of wearable, modular, high-density diffuse optical tomography (HD-DOT) technologies has recently emerged that overcomes many of the limitations of traditional, fibre-based and low-density fNIRS measurements. Driven by the development of this new technology, we have undertaken the first study of the infant brain using wearable HD-DOT. Using a well-established social stimulus paradigm, and combining this new imaging technology with advances in cap design and spatial registration, we show that it is now possible to obtain high-quality, functional images of the infant brain with minimal constraints on either the environment or on the infant participants. Our results are consistent with prior low-density fNIRS measures based on similar paradigms, but demonstrate superior spatial localization, improved depth specificity, higher SNR and a dramatic improvement in the consistency of the responses across participants. Our data retention rates also demonstrate that this new generation of wearable technology is well tolerated by the infant population.
Forward and adjoint Monte Carlo (MC) models of radiance are proposed for use in model-based quantitative photoacoustic tomography. A two-dimensional (2-D) radiance MC model using a harmonic angular basis is introduced and validated against analytic solutions for the radiance in heterogeneous media. A gradient-based optimization scheme is then used to recover 2-D absorption and scattering coefficients distributions from simulated photoacoustic measurements. It is shown that the functional gradients, which are a challenge to compute efficiently using MC models, can be calculated directly from the coefficients of the harmonic angular basis used in the forward and adjoint models. This work establishes a framework for transport-based quantitative photoacoustic tomography that can fully exploit emerging highly parallel computing architectures.
Biomedical photoacoustic (PA) tomography is a hybrid soft-tissue imaging modality that combines the high spatial resolution of ultrasound with the high contrast and specificity of optical imaging techniques.1–3 It relies on the generation of acoustic waves inside the tissue, which result from the absorption of intensity-modulated light, such as laser pulses or frequency chirps, by the tissue chromophores. From time-resolved PA signals recorded at multiple measurement points around the object, three-dimensional (3-D) data sets of the initial pressure distribution (i.e., PA images) can be calculated using acoustic reconstruction algorithms. Quantitative PA tomography (QPAT) aims to exploit the wavelength dependence of the image intensity to recover the local concentrations of endogenous tissue chromophores and exogenous contrast agents from which functional parameters, such as blood oxygen saturation, can be derived. To relate the PA image intensity to local chromophore concentrations, computational models of the physical processes during the image generation in conjunction with inversion schemes represent one approach to QPAT.4,5 A major challenge in QPAT is the unknown light fluence in the tissue,5–7 which is a nonlinear function of the concentrations and the scattering coefficient. Its effects on PA images have been described as spectral coloring and structural distortion.5 For an accurate quantification of concentrations and their ratios (e.g., blood oxygenation), the wavelength-dependent fluence distribution has to be accounted for.
The investigation of human brain function has made dramatic progress since the introduction and development of functional neuroimaging. Functional magnetic resonance imaging (fMRI) and positron emission tomography (PET) have been at the forefront of this development, but they are not free of limitations. Both impose significant constraints on the mobility of participants, which hinders their application in challenging populations such as infants and in the study of neural processes and behaviors that involve movement. Extended or repeated monitoring is also difficult due to the associated costs, the confined scanner environment and (in the case of PET) the use of radiotracers.1,2 In addition, fMRI has contraindications for electronic or metal implants (such as pacemakers, cochlear implants, aneurysm clips, and surgical devices). Owing to the large, fixed nature of MRI and PET equipment, and the requirement on the participant to lie flat, it is very difficult to study the brain in everyday scenarios, such as during face-to-face conversations.
The first wearable multi-wavelength technology for functional near-infrared spectroscopy has been developed, based on a custom-built 8-wavelength light emitting diode (LED) source. A lightweight fibreless probe is designed to monitor changes in the concentrations of multiple absorbers (chromophores) in biological tissue, the most dominant of which at near-infrared wavelengths are oxyhemoglobin and deoxyhemoglobin. The use of multiple wavelengths enables signals due to the less dominant chromophores to be more easily distinguished from those due to hemoglobin and thus provides more complete and accurate information about tissue oxygenation, hemodynamics, and metabolism. The spectroscopic probe employs four photodiode detectors coupled to a four-channel charge-to-digital converter which includes a charge integration amplifier and an analogue-to-digital converter (ADC). Use of two parallel charge integrators per detector enables one to accumulate charge while the other is being read out by the ADC, thus facilitating continuous operation without dead time. The detector system has a dynamic range of about 80 dB. The customized source consists of eight LED dies attached to a 2 mm × 2 mm substrate and encapsulated in UV-cured epoxy resin. Switching between dies is performed every 20 ms, synchronized to the detector integration period to within 100 ns. The spectroscopic probe has been designed to be fully compatible with simultaneous electroencephalography measurements. Results are presented from measurements on a phantom and a functional brain activation study on an adult volunteer, and the performance of the spectroscopic probe is shown to be very similar to that of a benchtop broadband spectroscopy system. The multi-wavelength capabilities and portability of this spectroscopic probe will create significant opportunities for in vivo studies in a range of clinical and life science applications.
Functional near-infrared spectroscopy (fNIRS) is a form of neuroimaging that is non-invasive and non-ionizing. The basic principle on which fNIRS is based is that human tissue is relatively transparent to red and near-infrared (NIR) wavelengths of light (at 650 to 1000 nm), and that in this region oxygenated hemoglobin (HbO) and deoxygenated hemoglobin (HbR) are the dominant absorbers. As a result, fNIRS is able to indirectly monitor functional brain activity by measuring changes in the concentrations of hemoglobins, which is also the basis of the blood-oxygen-level-dependent functional magnetic resonance imaging (fMRI) signal. While fMRI is primarily sensitive to changes in the concentration of HbR, fNIRS has the ability to differentiate between HbO and HbR, providing more complete information on hemodynamics and cerebral oxygenation.