20 February 2026 in IEEE Sensors Journal
Accurate monitoring of the blood glucose concentration is critically important for the diagnosis, treatment, and long-term management of diabetes. In this paper, an optical blood glucose sensing method is proposed on the basis of silicon-based waveguide Bragg grating (WBG). This method involves the reaction between glucose oxidase fixed on the cladding of the waveguide and glucose, which causes a local refractive index change, resulting in a shift in the WBG reflection center wavelength, enabling the quantitative detection of blood glucose concentration. Nevertheless, during measurement, optical blood glucose sensors are susceptible to spectral drifts caused by environmental temperature variations, leading to a decrease in sensing accuracy. To address this issue, a silicon-on-insulator (SOI) WBG sensor for glucose concentration measurement is proposed and implemented. Two types of WBG blood glucose sensors, namely, bilateral and slit sensors, are designed, incorporating an athermalization design to enhance system stability and environmental robustness. By employing a compensating material with a negative thermo-optic coefficient (TOC) and optimizing various waveguide structural parameters, temperature-induced drift is effectively suppressed, which enables the design of bilateral and slit WBG glucose sensors with both glucose sensing and temperature compensation capabilities. The experimental results show that the bilateral WBG glucose sensor exhibits a refractive index sensitivity of 161 nm/refractive index unit (RIU) and a temperature sensitivity of 7.27 pm/°C within a glucose concentration range of 0–2.6 mg/mL. The slit WBG glucose sensor has a refractive index sensitivity of 242.3 nm/RIU and a temperature sensitivity of 2.37 pm/°C within the 0–2.8 mg/mL glucose concentration range.
20 March 2025 in IEEE Transactions on Instrumentation and Measurement
Traditional electrical pressure sensors are prone to electromagnetic interference; however, the emergence of optical pressure sensors offers a novel means of fabricating flexible devices. A pressure sensor based on a polymer optical waveguide is presented in this article that incorporates three cascaded microring resonators (MRRs) for enhanced sensitivity and accuracy. The sensor was fabricated from a polymer with a low Young’s modulus to achieve flexibility and enhanced sensitivity. The wavelength change in the output spectrum of the sensor was utilized to precisely measure the pressure applied to the device, and the structural parameters and the cascaded array of MRRs were optimized to improve the sensitivity of the pressure sensor. The experimental results show that the sensor has a sensitivity of 21.86 pm/kPa within the pressure range of 0–20 kPa with an accuracy of 1 kPa. The proposed MRR array pressure sensor exhibits high sensitivity and excellent linearity, and can be easily integrated into a device, indicating considerable application potential for wearable optical sensing.
5 November 2025 in IEEE Sensors Journal
Silicon photonic biosensors can be fabricated via standard CMOS microfabrication techniques, with many sensing sites integrated on the same chip. In this work, we report the design and validation of a cascaded 1 × 4 racetrack-shaped microring resonator (rsMRR) based on silicon-on-insulator (SOI), optimizing key parameters, such as the waveguide width, coupling gap, and ring radius. Moreover, we comprehensively characterize the sensing performance of the rsMRR. The experimental results show that the resonator achieves a sensitivity of 117 nm/RIU within a glucose concentration range of 03.3 mg/mL. Compared with traditional structures, this design reduces optical loss through its racetrack-shaped layout, reaching a quality factor (Q-factor) of 510, and has advantages such as high integration density, anti-interference capability, and miniaturization. This work reveals the potential of silicon-based rsMRRs for practical glucose-sensing applications.