Louise Zhuang

Louise Zhuang

Auto-generated profile, based on publicly available information

Louise Zhuang

Department of Electrical Engineering, Stanford University, Stanford, CA, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023
Verified
Book Chapter
Closed access
PDF file
WSWalter Simson
Walter Simson
LZLouise Zhuang
Louise Zhuang
SSSergio Sanabria
Sergio Sanabria
NANeha Antil
Neha Antil
JDJeremy Dahl
Jeremy Dahl
DHDongwoon Hyun
Dongwoon Hyun

5 December 2025 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
LZLouise Zhuang
Louise Zhuang
OOOleksii Ostras
Oleksii Ostras
MSMasashi Sode
Masashi Sode
WSWalter Simson
Walter Simson
DHDongwoon Hyun
Dongwoon Hyun
GPGianmarco F. Pinton
Gianmarco F. Pinton
Transabdominal ultrasound imaging requires acoustic wave propagation through the abdominal wall, which consists of a complex organization of tissue layers that degrade imaging of underlying organs such as the liver. A priori knowledge of the acoustic properties of this medium could enable adaptive imaging techniques, but the underlying ground truth properties in a living patient is a fundamentally unknown quantity. Numerical simulations can offer a solution to this challenge by modeling the propagation of ultrasound imaging pulses in media with known acoustic properties and can therefore provide a quantitative relationship between the received ultrasound echoes and the underlying tissue structure. However, to be comparable with clinical scenarios, in silico phantoms of the abdominal wall must be geometrically and quantitatively accurate, with rigorous tolerances. Here, we describe a dataset generation approach to produce experimentally calibrated ultrasound data for transabdominal imaging. Semantically labeled 3D in silico phantoms with 0.33mm isotropic resolution, along with physical parameters from the literature of the human abdominal wall, are used to model acoustic propagation through human tissue. We perform 2D numerical simulations of the Westervelt equation to generate a dataset of raw ultrasound data for liver imaging consisting of 1027 samples. We then discuss the applications of this dataset for facilitating abdominal ultrasound imaging research. The labeled abdominal dataset, simulated data, and the simulation tools that model wave propagation are made publicly available.

31 October 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
BFBenjamin N. Frey
Benjamin N. Frey
DHDongwoon Hyun
Dongwoon Hyun
WSWalter Simson
Walter Simson
LZLouise Zhuang
Louise Zhuang
HHHoda S. Hashemi
Hoda S. Hashemi
JDJeremy Dahl
Jeremy Dahl
UltraFlex is an iterative model-based ultrasonic flexible-array shape calibration framework that uses automatic differentiation. This work evaluates array shape calibration model performance while examining multiple image quality metrics: speckle brightness, envelope entropy, coherence factor, lag-one coherence, common-midpoint correlation coefficient, and common-midpoint phase error. The accuracy of these image quality metrics was evaluated on simulated phantoms using a variety of array shapes. Experimental phantom and in vivo liver datasets were also investigated using transducers with known geometries. While speckle brightness, envelope entropy, and coherence factor enable model convergence under many conditions, lag-one coherence, common-midpoint correlation coefficient, and common-midpoint phase error enable more accurate element position estimations and improved visual ultrasound image focusing quality. Furthermore, the models based on the common-midpoint correlation coefficient and phase-error quality metrics are the most robust against additive white noise while achieving median mean Euclidean errors (MEEs) of 3.7μm for simulation, 29.7μm for phantom, and 69.0μm for in vivo liver data. These array shape calibration results show promise for future development of experimental flexible- and wearable-ultrasonic arrays.

3 April 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
SBSamuel Beuret
Samuel Beuret
LZLouise Zhuang
Louise Zhuang
JDJeremy Dahl
Jeremy Dahl
JTJean-Philippe Thiran
Jean-Philippe Thiran
Pulse-echo speed-of-sound imaging is emerging as a powerful extension of conventional echography. It shows particular promise for diagnosing metabolic dysfunction-associated steatotic liver disease, whose prevalence is increasing worldwide alongside obesity rates. However, current techniques often lack robustness, particularly when limited data are available. Existing methods rely on different regularization strategies to incorporate knowledge on the speed-of-sound distribution within tissues. In this work, we propose a novel regularization approach that automatically integrates information from the B-mode image. The proposed regularizer relies on the principle of sparsity with partially known support applied to a total variation norm, enabling increased robustness compared to regularizers disregarding information contained in B-mode images, or circumventing drawbacks of approaches based on the manual segmentation of the latter. We evaluate the proposed technique with simulated and in vivo data, considering both large and reduced datasets, with a specific focus on liver imaging. The results indicate that our method enhances speed-of-sound accuracy with simulated data when compared with regularizers proposed in the literature, whereas the robustness to data reduction is improved with in vivo data. Notably, our approach can facilitate the deployment of pulse-echo speed-of-sound imaging on ultra-portable transducers, which are typically constrained in data acquisition capacity.

6 May 2026 in Ultrasonic Imaging
Verified
Journal Article
Closed access
LZLouise Zhuang
Louise Zhuang
SSScott Schoen
Scott Schoen
JDJeremy Dahl
Jeremy Dahl
MJMarko Jakovljevic
Marko Jakovljevic
Synthetic aperture transmit sequences can be used in medical ultrasound to increase image resolution without sacrificing frame rate. However, beamforming the large amount of collected data from the sequence is computationally costly for traditional delay-and-sum (DAS) beamforming, and the sequence has low SNR and limited penetration depth. These problems are especially apparent for deeper targets, when more data is collected and the low SNR results in poor visibility. Transmitting a chirp coded excitation can greatly improve the SNR and penetration depth, at the cost of some computational efficiency during beamforming, although frequency-domain beamforming can reduce the computations required for image reconstruction. This paper presents the chirp scaling algorithm (CSA), a frequency-domain beamformer originally developed for radar, that avoids the computational costs of interpolation and can account inherently for chirp excitation pulse compression for chirp transmit sequences. First, theory is presented to derive the beamforming steps for ultrasound multistatic synthetic aperture data. Then, comparative imaging with DAS and the range-Doppler algorithm (RDA, a related frequency-domain beamformer) are shown via Field II simulations and in vitro with a CIRS phantom imaged using a Verasonics Vantage 256 system. The results demonstrate similar lateral sidelobe levels (averaging) within 6 dB and resolution within 0.1 mm for the three beamformers for all sources of data. However, CSA has consistently faster median baseline runtime (at least 2.6 times faster compared to DAS), and a significant 6.5-fold runtime decrease from via precomputation, which reduces its runtime below even that of RDA. Together, our results demonstrate the feasibility for CSA to generate high-quality ultrasound images, particularly for resource-constrained devices.