Hoda S. Hashemi

Hoda S. Hashemi

Auto-generated profile, based on publicly available information

Hoda S. Hashemi

Department of Radiology, Stanford University, Stanford, CA, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YSYanan Shao
Yanan Shao
HHHoda S. Hashemi
Hoda S. Hashemi
PGPaula B Gordon
Paula B Gordon
LWLinda Warren
Linda Warren
ZWZ. Jane Wang
Z. Jane Wang
SSSeptimiu Salcudean
Septimiu Salcudean
In shear wave absolute vibro-elastography (S-WAVE), a steady-state multi-frequency external mechanical excitation is applied to tissue, while a time-series of ultrasound radio-frequency (RF) data are acquired. Our objective is to determine the potential of S-WAVE to classify breast tissue lesions as malignant or benign. We present a new processing pipeline for feature-based classification of breast cancer using S-WAVE data, and we evaluate it on a new data set collected from 40 patients. Novel bi-spectral and Wigner spectrum features are computed directly from the RF time series and are combined with textural and spectral features from B-mode and elasticity images. The Random Forest permutation importance ranking and the Quadratic Mutual Information methods are used to reduce the number of features from 377 to 20. Support Vector Machines and Random Forest classifiers are used with leave-one-patient-out and Monte Carlo cross-validations. Classification results obtained for different feature sets are presented. Our best results (95% confidence interval, Area Under Curve = 95%±1.45%, sensitivity = 95%, and specificity = 93%) outperform the state-of-the-art reported S-WAVE breast cancer classification performance. The effect of feature selection and the sensitivity of the above classification results to changes in breast lesion contours is also studied. We demonstrate that time-series analysis of externally vibrated tissue as an elastography technique, even if the elasticity is not explicitly computed, has promise and should be pursued with larger patient datasets. Our study proposes novel directions in the field of elasticity imaging for tissue classification.

15 October 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HHHoda S. Hashemi
Hoda S. Hashemi
SFStefanie Fallone
Stefanie Fallone
MBMathieu Boily
Mathieu Boily
ATAnna Towers
Anna Towers
RKRobert D. Kilgour
Robert D. Kilgour
HRHassan Rivaz
Hassan Rivaz
Breast cancer-related lymphedema (BCRL) is a consequence of a malfunctioning lymphatic drainage system resulting from surgery or some other form of treatment. In the initial stages, minor and reversible increases in fluid volume of the arm are evident. As the stages progress over time, the underlying pathophysiology dramatically changes with an irreversible increase in arm volume most likely due to a chronic local inflammation leading to adipose tissue hypertrophy and fibrosis. Clinicians have subjective ways to stage the degree and severity such as the pitting test which entails manually comparing the elasticity of the affected and unaffected arms. Several imaging modalities can be used but ultrasound appears to be the most preferred because it is affordable, safe and portable. Unfortunately, ultrasonography is not typically used for staging lymphedema because the appearance of the affected and unaffected arms is similar in B-mode ultrasound images. However, novel ultrasound techniques have emerged, such as elastography that may be able to identify changes in mechanical properties of the tissue related to detection and staging of lymphedema. This paper presents a novel technique to compare the mechanical properties of the affected and unaffected arms using quasi-static ultrasound elastography to provide an objective alternative to the current subjective assessment. Elastography is based on Time Delay Estimation (TDE) from ultrasound images to infer displacement and mechanical properties of the tissue. We further introduce a novel method for TDE by incorporating higher-order derivatives of the ultrasound data into a cost function, and propose a novel optimization approach to efficiently minimize the cost function. This method works reliably with our challenging patient data. We collected Radio-Frequency (RF) ultrasound data from both arms of seven patients with Stage 2 lymphedema, at six different locations in each arm. The ratio of strain in skin, subcutaneous fat and skeletal muscle divided by strain in the standoff gel pad was calculated in the unaffected and affected arms. The p-values using a Wilcoxon sign-rank test for the skin, subcutaneous fat, and skeletal muscle were 1.24 × 10–5, 1.77 × 10–8, 8.11 × 10–7 respectively, showing differences between the unaffected and affected arms with a very high level of significance.

26 May 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SMShahed Mohammed
Shahed Mohammed
MHMohammad Honarvar
Mohammad Honarvar
QZQi Zeng
Qi Zeng
HHHoda Hashemi
Hoda Hashemi
RRRobert Rohling
Robert Rohling
SSSeptimiu Salcudean
Septimiu Salcudean
We introduce two model-based iterative methods to obtain shear modulus images of tissue using magnetic resonance elastography. The first method jointly finds the displacement field that best fits tissue displacement data and the corresponding shear modulus. The displacement satisfies a viscoelastic wave equation constraint, discretized using the finite element method. Sparsifying regularization terms in both shear modulus and displacement are used in the cost function minimized for the best fit. The second method extends the first method for multifrequency tissue displacement data. The formulated problems are biconvex. Their solution can be obtained iteratively by using the alternating direction method of multipliers. Sparsifying regularizations and the wave equation constraint filter out sensor noise and compressional waves. Our methods do not require bandpass filtering as a preprocessing step and converge fast irrespective of the initialization. We evaluate our new methods in multiple in silico and phantom experiments, with comparisons with existing methods, and we show improvements in contrast to noise and signal-tonoise ratios. Results from an in vivo liver imaging study show elastograms with mean elasticity comparable to other values reported in the literature.

26 May 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HHHoda S. Hashemi
Hoda S. Hashemi
SMShahed K. Mohammed
Shahed K. Mohammed
QZQi Zeng
Qi Zeng
RAReza Zahiri Azar
Reza Zahiri Azar
RRRobert Rohling
Robert Rohling
SSSeptimiu E. Salcudean
Septimiu E. Salcudean
Real-time ultrasound imaging plays an important role in ultrasound-guided interventions. 3D imaging provides more spatial information compared to conventional 2D frames by considering the volumes of data. One of the main bottlenecks of 3D imaging is the long data acquisition time which reduces practicality and can introduce artifacts from unwanted patient or sonographer motion. This paper introduces the first shear wave absolute vibro-elastography (S-WAVE) method with real-time volumetric acquisition using a matrix array transducer. In S-WAVE, an external vibration source generates mechanical vibrations inside the tissue. The tissue motion is then estimated and used in solving a wave equation inverse problem to provide the tissue elasticity. A matrix array transducer is used with a Verasonics ultrasound machine and frame rate of 2000 volumes/s to acquire 100 radio frequency (RF) volumes in 0.05 s. Using plane wave (PW) and compounded diverging wave (CDW) imaging methods, we estimate axial, lateral and elevational displacements over 3D volumes. The curl of the displacements is used with local frequency estimation to estimate elasticity in the acquired volumes. Ultrafast acquisition extends substantially the possible S-WAVE excitation frequency range, now up to 800 Hz, enabling new tissue modeling and characterization. The method was validated on three homogeneous liver fibrosis phantoms and on four different inclusions within a heterogeneous phantom. The homogeneous phantom results show less than 8% (PW) and 5% (CDW) difference between the manufacturer values and the corresponding estimated values over a frequency range of 80 Hz to 800 Hz. The estimated elasticity values for the heterogeneous phantom at 400 Hz excitation frequency show average errors of 9% (PW) and 6% (CDW) compared to the provided average values by MRE. Furthermore, both imaging methods were able to detect the inclusions within the elasticity volumes. An ex vivo study on a bovine liver sample shows less than 11% (PW) and 9% (CDW) difference between the estimated elasticity ranges by the proposed method and the elasticity ranges provided by MRE and ARFI.

31 October 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
BFBenjamin N. Frey
Benjamin N. Frey
DHDongwoon Hyun
Dongwoon Hyun
WSWalter Simson
Walter Simson
LZLouise Zhuang
Louise Zhuang
HHHoda S. Hashemi
Hoda S. Hashemi
JDJeremy Dahl
Jeremy Dahl
UltraFlex is an iterative model-based ultrasonic flexible-array shape calibration framework that uses automatic differentiation. This work evaluates array shape calibration model performance while examining multiple image quality metrics: speckle brightness, envelope entropy, coherence factor, lag-one coherence, common-midpoint correlation coefficient, and common-midpoint phase error. The accuracy of these image quality metrics was evaluated on simulated phantoms using a variety of array shapes. Experimental phantom and in vivo liver datasets were also investigated using transducers with known geometries. While speckle brightness, envelope entropy, and coherence factor enable model convergence under many conditions, lag-one coherence, common-midpoint correlation coefficient, and common-midpoint phase error enable more accurate element position estimations and improved visual ultrasound image focusing quality. Furthermore, the models based on the common-midpoint correlation coefficient and phase-error quality metrics are the most robust against additive white noise while achieving median mean Euclidean errors (MEEs) of 3.7μm for simulation, 29.7μm for phantom, and 69.0μm for in vivo liver data. These array shape calibration results show promise for future development of experimental flexible- and wearable-ultrasonic arrays.

23 December 2025 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
HHHoda S. Hashemi
Hoda S. Hashemi
DHDongwoon Hyun
Dongwoon Hyun
NNNathan Nguyen
Nathan Nguyen
JBJihye Baek
Jihye Baek
ANArutselvan Natarajan
Arutselvan Natarajan
JDJeremy Dahl
Jeremy Dahl
Ultrasound molecular imaging (UMI) is an advanced imaging modality that shows promise in detecting cancer at early stages. It uses microbubbles as contrast agents, which are functionalized to bind to cancer biomarkers overexpressed on endothelial cells. A major challenge in UMI is isolating bound microbubble signal, which represents the molecular imaging signal, from that of free-floating microbubbles, which is considered background noise. In this work, we propose a fast GPU-based method using robust principal component analysis (RPCA) to distinguish bound microbubbles from free-floating ones. We explore the method using simulations and measure the accuracy using the Dice coefficient and RMS error as functions of the number of frames used in RPCA reconstruction. Experiments using stationary and flowing microbubbles in tissue-mimicking phantoms were used to validate the method. Additionally, the method was applied to data from ten transgenic mouse models of breast cancer development, injected with B7-H3 targeted microbubbles, and two mice injected with non-targeted microbubbles. The results showed that RPCA using 20 frames achieved a Dice score of 0.95 and a computation time of 0.2 seconds, indicating that 20 frames is potentially suitable for real-time implementation. On in vivo data, RPCA using 20 frames achieved a Dice score of 0.82 when compared with a conventional preclinical method, Differential Targeted Enhancement (DTE), indicating good agreement between the two, given the limitations of each method.