Li-Wen Chiu

Li-Wen Chiu

Auto-generated profile, based on publicly available information

Li-Wen Chiu

Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2023 in IEEE Transactions on Affective Computing
Verified
Journal Article
Closed access
YWYi-Chiao Wu
Yi-Chiao Wu
LCLi-Wen Chiu
Li-Wen Chiu
CLChun-Chih Lai
Chun-Chih Lai
BWBing-Fei Wu
Bing-Fei Wu
SLSunny S.J. Lin
Sunny S.J. Lin
Complex emotion is an aggregate of two or more others which has highly variable appearances, inter-dependence, and affective dynamics.These properties make the recognition hard to handle via existing recognition techniques like action units or valence-arousal detection. In this study, we propose a bionic two-system structure for complex emotion recognition. The structure mimics the working theory of the human brain responding to problems decision-making. System I is a fast compound sensing module. System II is a slower cognitive decision module that processes data more integratively. System I contains one branch for facial expression feature representation including basic emotion, action units, and valence arousal detection and one for physiological measurement which is an image-only implementation for practicality. In System II, a decision module with segmentation is employed to ensure the chosen period including the emotion occurrence and iteratively optimize the emotion information in a given segment via reinforcement learning. The proposed method outperforms state-of-the-art on emotion recognition tasks with an accuracy of 94.15% in basic emotion recognition on the BP4D and an accuracy of 68.75% for binary valence arousal classification on the DEAP. For a subset of complex emotions, the recognition accuracy exceeds 70% on both databases, that is a significant improvement.

30 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCLi-Wen Chiu
Li-Wen Chiu
YCYang-Ren Chou
Yang-Ren Chou
YWYi-Chiao Wu
Yi-Chiao Wu
BWBing-Fei Wu
Bing-Fei Wu
Driver monitoring is a popular topic of investigation. Contactless vital-sign measurement via remote photoplethysmography (rPPG) is an easy and effective alternative to cumbersome wearable devices during driving. However, driving is a noise-heavy situation for remote vital-sign sensing, owing to the disturbances caused by jolted cars or varying illumination from time and weather variations. In this study, we propose deep-learning models for rPPG construction and heart-rate estimation that work for both red-green-blue (RGB) and monochrome near-infrared (NIR) images. The proposed method overcomes the adaptation issues commonly seen in deep-learning based heart-rate estimation approaches and achieves a significant improvement in robustness for heart-rate measurement. To evaluate the performance thoroughly, in addition to a public dataset, we construct four testing driving sets for various practical conditions, including driving at night, on rainy days, and on long-term journeys. It is also worth noting that we conducted the assessment with a cross-dataset protocol to further verify the efficiency of our method. The experimental results on the five datasets show that our proposed method can perform better than the state-of-the-art method for both RGB and NIR images, especially in some challenging cases. The root-mean-square error (RMSE) for the situation with additional head motion conditions can be improved by 28.6% with RGB images and by 21.91% with NIR images on the open dataset. Moreover, RMSE can be improved by up to 42.6% at night, 14.41% on rainy days, and 18.78% on long-term journeys.

10 April 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
BWBing-Fei Wu
Bing-Fei Wu
LCLi-Wen Chiu
Li-Wen Chiu
YWYi-Chiao Wu
Yi-Chiao Wu
CLChun-Chih Lai
Chun-Chih Lai
HCHao-Min Cheng
Hao-Min Cheng
Pao-Hsien ChuPao-Hsien Chu
Pao-Hsien Chu
Remote photoplethysmography (rPPG) has been used to measure vital signs such as heart rate, heart rate variability, blood pressure(BP), and blood oxygen. Recent studies adopt features developed with photoplethysmography (PPG) to achieve contactless BP measurement via rPPG. These features can be classified into two groups: time or phase differences from multiple signals, or waveform feature analysis from a single signal. Here we devise a solution to extract the time difference information from the rPPG signal captured at 30 FPS. We also propose a deep learning model architecture to estimate BP from the extracted features. To prevent overfitting and compensate for the lack of data, we leverage a multi-model design and generate synthetic data. We also use subject information related to BP to assist in model learning. For real-world usage, the subject information is replaced with values estimated from face images, with performance that is still better than the state-of-the-art. To our best knowledge, the improvements can be achieved because of: (1) the model selection with estimated subject information, (2) replacing the estimated subject information with the real one, (3) the InfoGAN assistance training (synthetic data generation), and (4) the time difference features as model input. To evaluate the performance of the proposed method, we conduct a series of experiments, including dynamic BP measurement for many single subjects and nighttime BP measurement with infrared lighting. Our approach reduces the MAE from 15.49 to 8.78 mmHg for systolic blood pressure (SBP) and 10.56 to 6.16 mmHg for diastolic blood pressure(DBP) on a self-constructed rPPG dataset. On the Taipei Veterans General Hospital(TVGH) dataset for nighttime applications, the MAE is reduced from 21.58 to 11.12 mmHg for SBP and 9.74 to 7.59 mmHg for DBP, with improvement ratios of 48.47% and 22.07% respectively.

13 March 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYi-Chiao Wu
Yi-Chiao Wu
LCLi-Wen Chiu
Li-Wen Chiu
BWBing-Fei Wu
Bing-Fei Wu
LLLinda Li-chuan Lin
Linda Li-chuan Lin
THTsai-Hsuan Ho
Tsai-Hsuan Ho
SWShou-Fang Wu
Shou-Fang Wu
Monitoring the subject’s physical activity intensity (PAI) is key to preventing sports injury and enhancing conditioning performance. Existing monitoring equipment can be cumbersome and is not always accessible in daily situations due to cost or usability. For ease of usage, we propose a motion robust remote photoplethysmography (rPPG) measurement during exercise for contactless PAI detection. To account for vigorous motion during physical exercise, we leverage signal holding with motion analysis to maintain the consistency of the signal source. We then obtain robust rPPG signals via a convolutional neural network (CNN) based rPPG constructor module composed of a dual feature extractor with signal-based targets, a bases span module, and a noise elimination module. In terms of the PAI detection application, as changes in heart rate are a dominant biomarker during exercise, this is applied to estimate the training level for PAI detection. In this study, training status is classified into three levels and is estimated via a residual-learning-based architecture with sequential heart rate input. In terms of heart rate measurements, the proposed method outperforms state-of-the-art approaches in motion scenarios on both ECG-Fitness and our own exercise datasets. The mean absolute error (MAE) is reduced to about one-third of the comparison methods in real-world treadmill running scenarios, and the error level goes down by about 30% in ECG-Fitness dataset under a cross-dataset evaluation. In addition, for follow-up PAI detection applications, the heart rate values estimated with the proposed method approximate the heart rate ground truth. It is capable to represent the trend between training load and PAI changes. We propose a novel framework for the motion robust rPPG measurement during exercise applied to PAI detection, with which overall athlete assessment can be accomplished as a convenient alternative to existing athlete monitoring equipment.

3 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCLi-Wen Chiu
Li-Wen Chiu
YCYang-Ren Chou
Yang-Ren Chou
YWYi-Chiao Wu
Yi-Chiao Wu
MCMeng-Liang Chung
Meng-Liang Chung
BWBing-Fei Wu
Bing-Fei Wu
KCKun-Ta Chou
Kun-Ta Chou
In recent years, sleep apnea (SA) detection has attracted increasing attention worldwide. Polysomnography (PSG) is currently considered the gold standard for sleep monitoring, but its limitations have hindered widespread adoption. Therefore, we propose a video-based contactless SA detection technique. Only a single camera is needed to capture sleep images, and images of the nose, throat, and face are selected to extract respiratory motion signals and physiological signals, including optical flow, remote photoplethysmography (rPPG), and heart rate variability. These signals are used for SA classification on per-minute segments and to assess the severity of the apnea-hypopnea index (AHI) throughout overnight sleep. Compared with existing methods, our proposed approach has the advantages of being non-contact, low-cost, and easy to use. This allows users to maintain their usual sleep conditions, making monitoring more convenient. In evaluation experiments using a self-constructed rPPG-SA dataset involving 61 participants, the proposed method achieves results comparable to existing contact-based methods with 10 subjects as training data and the other 51 subjects as testing data. The accuracy for binary classification of SA segments reaches 78.45% with a sensitivity of 79.03% and a specificity of 78.12%. In further experiments predicting the severity of AHI over the entire night, the accuracy for detecting moderate and severe levels (AHI ≥ 15) reaches 76.47% with sensitivity of 84.85% and specificity of 61.11%. Therefore, the proposed method not only offers the advantages of convenience and comfort in terms of device usage but also achieves comparable performance to contact-based algorithms.

20 January 2022 in IEEE Access
Verified
Journal Article
Open access
BWBing-Fei Wu
Bing-Fei Wu
YWYi-Chiao Wu
Yi-Chiao Wu
LCLi-Wen Chiu
Li-Wen Chiu
HLHsuan-Po Liu
Hsuan-Po Liu
In classification tasks, training labels are usually specified as one-hot targets which represent each class equally and exclusively. However, this labeling rule is not suitable in some situations. For the dependent classes, one-hot targets are not capable to represent the relation among them. The existing label smoothing methods just split the target response into neighboring classes, but it is only applied for ordinal classification, but not for the dependent but non-ordered classes. In this paper, we propose a novel labeling rule that decomposes the one-hot target into several bases to reflect relationships among classes while maintaining a balanced target space, which adopts channel encoding from communication systems, in particular, Bose–Chaudhuri–Hocquenghem (BCH) encoding. Besides, BCH encoder has an error-correcting mechanism that is expected to lift the accuracy. In theory, training with BCH targets ensures improved classification performance given the original accuracy is not less than 50%. To verify the proposed method on dependent classification, we conduct experiments with two facial tasks: age recognition and face anti-spoofing. The former is an ordinal classification task, and the latter is also regarded as a specific dependent classification problem due to the varying attack types being classified as one class finally and real for the other. Experimental results show that the proposed method improves accuracy by 6.33% on age recognition and reduces HTER by 3.63% for face anti-spoofing. In addition, as BCH targets divide the original response into a higher dimensional space, that is, the model is made to be heeded on learning the delicate sub-features. Hence, BCH targets also enhance model generalizability, thus guaranteeing improved performance on cross-domain evaluations. We further perform an assessment on the PACS dataset for evaluating domain generalizability. The results show that the domain generalizability is enhanced by increasing average accuracy by over 2% training with BCH targets.