Meng-Liang Chung

Meng-Liang Chung

Auto-generated profile, based on publicly available information

Meng-Liang Chung

FaceHeart Inc., Hsinchu, Taiwan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
BWBing-Fei Wu
Bing-Fei Wu
BWBing-Jhang Wu
Bing-Jhang Wu
SCShao-En Cheng
Shao-En Cheng
YSYu Sun
Yu Sun
MCMeng-Liang Chung
Meng-Liang Chung
Atrial fibrillation (AF) has been proven highly correlated to stroke; more than 43 million people suffer from AF worldwide. However, most of these patients are unaware of their disease. There is no convenient tool by which to conduct a comprehensive screening to identify asymptomatic AF patients. Hence, we provide a non-contact AF detection approach based on remote photoplethysmography (rPPG). We address motion disturbance, the most challenging issue in rPPG technology, with the NR-Net, ATT-Net, and SQ-Mask modules. NR-Net is designed to eliminate motion noise with a CNN model, and ATT-Net and SQ-Mask utilize channel-wise and temporal attention to reduce the influence of poor signal segments. Moreover, we present an AF dataset collected from hospital wards which contains 452 subjects (mean age, 69.313.0 years; women, 46%) and 7,306 30-second segments to verify the proposed algorithm. To our best knowledge, this dataset has the most participants and covers the full age range of possible AF patients. The proposed method yields accuracy, sensitivity, and specificity of 95.69%, 96.76%, and 94.33%, respectively, when discriminating AF from normal sinus rhythm. More than previous studies, other arrhythmias are also taken into consideration, leading to a further investigation of AF vs. Non-AF and AF vs. Other scenarios. For the three scenarios, the proposed approach outperforms the benchmark algorithms. Additionally, the accuracy of the slight motion data improves to 95.82%, 92.39%, and 89.18% for the three scenarios, respectively, while that of full motion data increases by over 3%.

13 March 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYi-Chiao Wu
Yi-Chiao Wu
LCLi-Wen Chiu
Li-Wen Chiu
BWBing-Fei Wu
Bing-Fei Wu
LLLinda Li-chuan Lin
Linda Li-chuan Lin
THTsai-Hsuan Ho
Tsai-Hsuan Ho
SWShou-Fang Wu
Shou-Fang Wu
Monitoring the subject’s physical activity intensity (PAI) is key to preventing sports injury and enhancing conditioning performance. Existing monitoring equipment can be cumbersome and is not always accessible in daily situations due to cost or usability. For ease of usage, we propose a motion robust remote photoplethysmography (rPPG) measurement during exercise for contactless PAI detection. To account for vigorous motion during physical exercise, we leverage signal holding with motion analysis to maintain the consistency of the signal source. We then obtain robust rPPG signals via a convolutional neural network (CNN) based rPPG constructor module composed of a dual feature extractor with signal-based targets, a bases span module, and a noise elimination module. In terms of the PAI detection application, as changes in heart rate are a dominant biomarker during exercise, this is applied to estimate the training level for PAI detection. In this study, training status is classified into three levels and is estimated via a residual-learning-based architecture with sequential heart rate input. In terms of heart rate measurements, the proposed method outperforms state-of-the-art approaches in motion scenarios on both ECG-Fitness and our own exercise datasets. The mean absolute error (MAE) is reduced to about one-third of the comparison methods in real-world treadmill running scenarios, and the error level goes down by about 30% in ECG-Fitness dataset under a cross-dataset evaluation. In addition, for follow-up PAI detection applications, the heart rate values estimated with the proposed method approximate the heart rate ground truth. It is capable to represent the trend between training load and PAI changes. We propose a novel framework for the motion robust rPPG measurement during exercise applied to PAI detection, with which overall athlete assessment can be accomplished as a convenient alternative to existing athlete monitoring equipment.

3 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCLi-Wen Chiu
Li-Wen Chiu
YCYang-Ren Chou
Yang-Ren Chou
YWYi-Chiao Wu
Yi-Chiao Wu
MCMeng-Liang Chung
Meng-Liang Chung
BWBing-Fei Wu
Bing-Fei Wu
KCKun-Ta Chou
Kun-Ta Chou
In recent years, sleep apnea (SA) detection has attracted increasing attention worldwide. Polysomnography (PSG) is currently considered the gold standard for sleep monitoring, but its limitations have hindered widespread adoption. Therefore, we propose a video-based contactless SA detection technique. Only a single camera is needed to capture sleep images, and images of the nose, throat, and face are selected to extract respiratory motion signals and physiological signals, including optical flow, remote photoplethysmography (rPPG), and heart rate variability. These signals are used for SA classification on per-minute segments and to assess the severity of the apnea-hypopnea index (AHI) throughout overnight sleep. Compared with existing methods, our proposed approach has the advantages of being non-contact, low-cost, and easy to use. This allows users to maintain their usual sleep conditions, making monitoring more convenient. In evaluation experiments using a self-constructed rPPG-SA dataset involving 61 participants, the proposed method achieves results comparable to existing contact-based methods with 10 subjects as training data and the other 51 subjects as testing data. The accuracy for binary classification of SA segments reaches 78.45% with a sensitivity of 79.03% and a specificity of 78.12%. In further experiments predicting the severity of AHI over the entire night, the accuracy for detecting moderate and severe levels (AHI ≥ 15) reaches 76.47% with sensitivity of 84.85% and specificity of 61.11%. Therefore, the proposed method not only offers the advantages of convenience and comfort in terms of device usage but also achieves comparable performance to contact-based algorithms.

27 February 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YWYi-Chiao Wu
Yi-Chiao Wu
CLChun-Hsien Lin
Chun-Hsien Lin
LCLi-Wen Chiu
Li-Wen Chiu
BWBing-Fei Wu
Bing-Fei Wu
MCMeng-Liang Chung
Meng-Liang Chung
YSYu Sun
Yu Sun
Atrial Fibrillation (AF) screening from face videos has become popular with the trend of telemedicine and telehealth in recent years. In this study, the largest facial image database for camera-based AF detection is proposed. There are 657 participants from two clinical sites and each of them is recorded for about 10 minutes of video data, which can be further processed as over 10,000 segments around 30 seconds, where the duration setting is referred to the guideline of AF diagnosis. It is also worth noting that, 2,979 segments are segment-wise labeled, that is, every rhythm is independently labeled with AF or not. Besides, all labels are confirmed by the cardiologist manually. Various environments, talking, facial expressions, and head movements are involved in data collection, which meets the situations in practical usage. Specific to camera-based AF screening, a novel CNN-based architecture equipped with an attention mechanism is proposed. It is capable of fusing heartbeat consistency, heart rate variability derived from remote photoplethysmography, and motion features simultaneously to reliable outputs. With the proposed model, the performance of intra-database evaluation comes up to 96.62% of sensitivity, 90.61% of specificity, and 0.96 of AUC. Furthermore, to check the capability of adaptation of the proposed method thoroughly, the cross-database evaluation is also conducted, and the performance also reaches about 90% on average with the AUCs being over 0.94 in both clinical sites.